24hrs Dynamic Ecg Holter System Tlc9803 3 Channel Ecg Holter Ekg Holter Recorder

US $84

  • Beijing, China
  • Jun 9th
   TLC9803 Dynamic ECG Systems 24 Hours Recorder Introduction TLC9803 Dynamic ECG Systems adapts 3-lead system defined by our company, can record continuously ECG waves for 24h, and analyses waves with PC software. It is applicable in hospital and community medical establishment.   Main Features ?Quick and accurate analysis system. ?The 3-lead synchro analysis, to find accurate, QRS search can be accurate and no distortion. ?There are more than 10 templates as atrial premature beat module, ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc. and multiplicate User-defined templates could almost identify every kind of pathologic waveforms. ?Flexible analysis channel selection function, can choose any channel as the mainly analysis the channel. ?Flexible atrial fibrillation analysis,so that physicians can use full,segmented automatic,manual analysis of atrial fibrillation,make the analysis more quickly and accurately. ?Powerful pacemaker analysis, on the AAI,VVI,DDD etc. all pacemaker analysis. ?Many pacing modules have been added. ?Fast review analysis function, can be any period of time the review single lead or all leads electrocardiogram. ?Analysis of heard rate variability with short-range 5 minutes and long-range 1 hour and 24 hours analysis of heart rate variability. ?One-stop printing operation, report printing process is convenient and quick. ?Perfect function of case management. ?Advanced ST segment analysis and myocardial ischemia total load, can for the ST abnormal analysis according to the whole and event, make the doctor can comprehensive judgment myocardial ischemia. ?Unique "Sleep breath pause syndrome analysis" analysis can predict Sleep breath pause risk. ?"HRT" analysis can predict the risk of death in patients with myocardial infarction. ?"T Wave alternation" analysis is an important index to predict malignant arrhythmia and sudden cardiac death.   Recorder features ?With advanced design and technology, the recorder can work stably, dependably and durably. ?Be provided with the capability of anti-jamming and aseismatic. ?Small volume with OLED screen. The resolution is 160*128. ?Be provided with functions of waveform preview, record review and event marking. ?Accurate record of the start time of the data sampled owing to the real time clock of itself. ?Avoid damage owing to the repeating inserting and pulling out by using the inbuilt TF card to storage the data. ?The maximum capability can be 2GB, so the original data can be saved perfectly by no compression. ?The average review time of single case can be less than 40 seconds by using interface of USB 2.0. ?Record waveform details inextenso by the design of high precision and sampling frequency. ?Record the state of pacemaker exactly by higher sampling frequency. The features of software ?Quick and accurate analysis system. ?With 3 leads synchro analysis, QRS search can be more exactly. ? There are more than 10 templates as atrial premature beat module,   ventricular premature beat module, long interval module, atrial flutter module,  atrial fibrillation module etc. and multiplicate User-defined templates could almost   identify every kind of pathologic waveforms. ?Optional main channel. ? Agile and exact "Atrial Fibrillation" analysis. ?The function of pacing analysis could analyse all pacemakers.  ? Many pacine modules have been added. ? Any period of single lead or 3-leads ECG can be reviewed at any time with the    function of fast waveform review and analysis. ? The types of the analysis system of HR variability include five minutes of short     ECG and one hour or 24-hour of long ECG. ? Print report expediently. ? Perfect function of case management.   ? With the function of ST segment analysis and general load of the disorder of the heart muscle,   the physician can judge a disease or disorder of the heart muscle generally. ?"Sleep breath pause syndrome analysis", the physician could print sleep asphyxia     analysis report and diagnose. ?"HRT" analysis, when the adjustable function is natural, this transitory change    will be represented by the form of HRT immediately. ?15."T Wave Alternation" analysis is a important index on judging and preventing arrhythmia.  Standard Number of channels: 3 channels; Sampling rate: 10000Hz; Sampling accuracy:12bit; Recording time : 24 h; Power: 2 batteries in size 5; Interface: USB2.0; Scale voltage:1mV±5%; Standard Sensitivity:10mm/mV±5%; Noise level:=60dB; Feathers of low frequency : Time constant>3.2s; Scan speed:25mm/s±5%; Enduring polarization voltage:±300mV; Least measure signal : 50 µV p-p; Product safety type : Type B (Internally powered); Size:111mm(L)*60mm(W)*25mm(H); Net Weight: 102g (Without battery). Packing List: ?  1 Holter recorder ?  1 CD of software ?  10 pieces of patient cable ?  220 pieces of disposable ECG Electrodes  ?  1 porch for hanging recorder ?  1 USB cable for data download ?  Instruction Manual ?  2 year warranty ?  1 microdog TLC6000 48 hours Dynamic 12-lead ECG Recorder/Analyzer,ECG/EKG Holter TLC6000 + Software TLC5000 24Hrs Dynamic ECG Holter System 12 Channel ECG/EKG Holter Recorder + SoftWare Please read the description of item carefully, thanks very much.  ? Usually we shipping the goods by EMS Express (for US, CA, AU and Most European Countries, 7-10 days arrive)     or International Air Parcel (for other Countries like South America and Africa, 25-35 days arrive).   ? If you want receive this goods more quickly, we also can shipping by DHL Express, but you need pay more postage, please contact us before you purchase.  ? We will follow your ebay address information to transport of goods, if you change your address, please contact us in time.  All emails or questions will be replyed within 24 hours. Please Note:  • Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility.  • Please check with your country's customs office to determine what these additional costs will be prior to bidding/buying. Contact person: Wendy Email address and skype is: medonlineshop@hotmail.com Please feel free to contact me. If you need more, I can give you a discount!    We will leave your positive feedback and send the goods immediately  when recieved your payment .Meanwhile please leave me a positive feedback if you are satisfied with our products, thanks!Your positive feedback will be appreciated very much, and in any case, please do contact us before leaving nagative feedback or ship the item back, we promise we will give you a satisfied answer. If your item arrived damaged or defective or if you received the wrong product or the item is not working according to its technical spec,  you may return it to us for a replacement item or a full refund, This should be done within 14 days from the day you received the item.  We will send you a new unit or refund the full payment you paid. The device comes with 2 years limited warranty from all factory defects. If any component fails within warranty period, we will repair or replace the defective component. Contec Medical Systems focusing on research,manufacture and distribution of medical instruments,was founded in 1992 as a high-tech company. At present we have 33 branch offices in China and more than 1500 employees. Our product line covers a wide range of 13 categories. Thousands of domestic hospitals are our customers. We have passed ISO 9000 and some of our products have got CE certificate.  Contec hopes to cooperate with international companies to supply more innovative design and advanced technology products at affordable prices. Agent in the world! We are looking for partners in the world now! Do you want to become our agent in your country?  Join us! The Fingertip PulseOximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 136606, and certified by FDA of United States and CE,TUV of Europe. The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:The sale of this item may be subject to regulation by the U.S. Food and Drug Admin-istration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser.If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.

Directions

Similar products from Other Lab Utensils & Expendables

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies