3-channel Ecg Holter System/recorder Monitor Analyzer Software+**3 Y Warranty**

US $699.00

  • United States
  • Mar 4th
Product Display  Newest Version no need Dangle key 3-channel ECG EKG Holter Recorder Free NEW Analyzer Software                 Description   Version: NEW CardioScape Holter   Model: CS-3CL   Software Functions & Features: QRS Templates Apply Demix technology, ensures the accuracy of QRS templates, includes N (Normal), V (Ventricular Ectopy), S (SVE), U (Unknown), P (Pacemaker), A (Artifact). All the templates can be combined or separated as individual beats. beats can be superimposed. Weak signal can be identified such as P wave. Arrhythmia Analysis VE, SVE, aberrant beats, V-Tach, V-Pair, V-Bigeminy, Tri-geminy etc. HRT (VE Chaos) Analysis HRT is the most powerful ECG-related risk predictor for assessing the death risk following myocardial infarction. The predictive value is comparable with that of the LVEF. Pacemaker Analysis Unique pacemaker analysis is suitable for various models i.e. AAI, VVI, DDD, DDR pacemakers. HRV (Heart Rate Variability) Analysis Time domain and Spectral domain HRV analysis, superlower HRV analysis Heart Rate Variability is analyzed in both Time Domain and Frequency. The top of the HRV display shows the Poincare-Lorenz scatter plots. The lower left shows the Frequency power graph. The range boundaries for LF, LF and HF can be adjusted. The lower right shows the Time Domain histogram. Day and night times can be entered for Sleep Apnea and for A-Fib. Atrial Fibrillation and Atrial Flutter Analysis Atrial Fibrillation is very important for the cardiologist concern. Holter ECG is an excellent test to detect transient A-Fib. TWA (T-wave alterans) Analysis Unknown for the past 40 years, T-Wave Alternans (TWA) in excess of 20 micro-volts have been in Holter recordings but have been undetected. TWA is a strong predictor of V-Tach and other serious cardiac abnormalities. It takes less than 10-seconds to do a complete 24-hour TWA analysis. You can check for TWA anywhere in teh 24-hour ECG file. Not only can you detect TWA in the ECG file, this software lets you view the ECG showing the actual TWA, so that you can verify and validate the presence of real TWA. The TWA algorithm detects two modes of TWA. Mode 1 is the beat-to-beat change in T-Wave amplitudes exceeding 20 micro-volts, as shown in the adjacent picture. Mode 2 is the gradual up and down changes of T-wave amplitudes over a series of several beats.   Features: 12-lead Color LCD Holter recorder  Compact size, light weight  Fully programmable, high Fidelity  Lower power consumption Fast data transfer Pacemaker detection Specification: Channel: 3 digital recording channels for 12-lead Sample rate: 1000Hz Resolution: 12 bit sampling Frequency response: 0.05-60Hz Recording time: 24 hours, full disclosure, no data compression, 12-lead ECG Storage: 2G built-in flash memory LCD display: ECG waveform and lead number Dimension: 80mmx45mmx18mm Weight: 75 grams (battery not included) Lead: 10 wire patient cable (I, II, III, aVR, aVL, aVF, V1~V6) Power: 2 AA size battery Packing list: 1. Holter Recorder: 1 set (Newest Version,so no dangle key) 2. Software: 1 pc (Newest Version) 3. 5-lead Holter lead wire: 1 set 4. Operation Manual: 1 set   Shipping 1.All item will be shipped by EMS postage within 1 business days. It takes approximately 5-15 business days to arrive.other country 8-28 business days. 2. EMS with tracking number, If some country EMS can not arrive, please pay US$25.0 for DHL. 3.All items will be shipped to buy's PayPal address. Please check your PayPal address is right 4.You must offer home or mobile phone when the item's Value exceed 100(USD,EUR,AUD,GBP) Warranty The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item Return Policy If you receive a defective item which you want to return, please contact us within 2 days from the day you receive the item. All return items must be returned with its original packaging and accessories. If we confirm the damage happened during the shipment, we will bear the shipping cost for return We will refund the money to you when we get the return items. Or replace item for you free of charge Tax,Customs&Duties We don't add taxes, VAT or other hidden charges. You pay us what you see on the invoice, i.e. goods subtotal + shipping cost (not include duties). Please find out as much as you can about your import taxes in your own country before bidding the item. You need to pay for the import duties in case that occurred for certain goods, or you may kindly give us some suggestions about that, we promise to do our best to help you Feedback Policy Customer is always NO.1 We care about our valued customers and understand the concerns and frustrations you might have, and will try our best to resolve the issues.. We strive to answer all emails as quickly as possible, but due to high email volume it may take time for us to reply. Thanks in advance for your patience! Contact us first before leaving a negative, we will find a solution to meet your requirement and enhance the satisfaction. Due to some ISP SPAM filter set        eBay Cross Border Trade powered by Channel Effect

Directions

Similar products from ECG & EKG Devices

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies