Atlantis Brain Master Neurofeedback Amplifyier

US $400

  • Piqua, Ohio, United States
  • May 26th
I bought this Atlantis on 9/30/2015 It has a Clinical Passkey with BioExplorer enabled,This is like knew with maybe 20 hours on it. I paid $1,624.00 for it. This is a very nice clean working amp that comes with serial key and CD download. Any Questions please feel free to contact me. The Brainmaster Atlantis II provides two channels of EEG and two channels of AUX signals for additional biofeedback modalities. Features built in EEG driven photic stim and USB interface. Simultaneous real time feedback produces an immersive sensory experience that is comprehensive, yet simple. The innovative Triamp bioamplifier records and reports the EEG signal, the DC and slow cortical potentials, and the continuous impedance measurement of the sensors in real time. The simplicity of design functionality allows you to easily conduct multi-modality feedback and control for maximum effect. Atlantis powerful hardware and software technology provides rapid and accurate responses and autonomous real-time EEG-controlled feedback without a PC, and real time impedance monitoring not merely impedance checking. The ability to simultaneously and continuously measure the EEG signal, the DC potential, the SCP (slow-cortical potential) and the impedance of both the active and reference leads opens up opportunities for new research and clinical work. The Atlantis is ideal for those ready to get started in this new age of neurofeedback monitoring at an economical investment. The Atlantis I is completely expandable and provides unparalleled results. EEG inputs sampled with 24 bits. Maximum EEG sampling rate (1 channel) 8192 samples/second. Presently emulating 2.5W. Continual impedance checking EEG biofeedback system with USB interface (no batteries, no power cord). Total immersion feature photic, vibrotactile, auditory) internal autonomous functions presently functioning with 2.5W. 2.5SE Software shielded cable hardware documentation 5 gold plated electrodes designer carrying bag Configuration 2 X 2:2 channels EEG AC/DC/Impedance 2 channels biopotential AC/DC/Impedance Additional Inputs: Event switch (stereo) Additional Outputs/Controls:EEG-controlled Photic Stimulator EEG-controlled Auditory Stimulator EEG-controlled Vibrotactile Stimulator Interface to PC: USB (optically isolated to 4500 volts) Power: Isolated power via USB port (magnetically isolated - no batteries) EEG:Number of EEG channels: 2 Amplifier type: BrainMaster Triamptm (simultaneous AC/DC/Impedance recording) Inputs: Bipolar: Separate Active and Reference per channel, shared isolated ground Connector: Proprietary 9-pin connector: signals/impedance sense/ground/power EEG A/D Resolution: 24 bits EEG A/D Accuracy: 0.023 microvolts EEG A/D Full Scale Range: +/- 190 millivolts Typical EEG internal sampling/operating rate (4 channels): 1024 samples/second (with continuous impedance monitoring) Maximum EEG sampling rate ( 4 channels): 4096 samples/second (without continuous impedance monitoring) Maximum EEG sampling rate (1 channel): 8192 samples/second (without continuous impedance monitoring) Common-mode Rejection Ratio: > 120dB Input Impedance: > 1000 GOhm Input noise: < 0.5 microvolts Standard Operating Bandwidth: 0.0 (DC) 120.0 Hz (1024 samples/second internal, 256 samples/second sent to PC) Maximum Operating Bandwidth (4 channels): DC 2048 Hz. (4096 samples/ second internal, 4096 samples/second sent to PC) Maximum Operating Bandwidth (1 channel): DC 4096 Hz. (8192 samples/ second internal, 8192 samples/second sent to PC) 0-10,000 Hz (1 channel) Continuous Sensor Impedance Monitoring for EEG:Resolution: 12 bits Impedance range: 0 1 Megohm Impedance accuracy: < 250 Ohm Front panel indicators: 8 tri-color (R/Y/G) LEDs indicating impedance via color and flash rate Separate indicators for active and reference leads (total 8 indicators for 4 channels) Impedance Indicator Levels: <5K, <10K, <20K, <50K, <100K Aux Channels:Number of Aux channels: 2 Amplifier type: BrainMaster Triamp (simultaneous AC/DC/Impedance recording) Inputs: Single Ended: Single Active per channel, shared isolated ground Connector: 2.5mm 4-connector mini-phono jack: signals/gnd/power Aux A/D Resolution: 12 bits Aux A/DAccuracy: 0.2 millivolts Aux A/D Full Scale range: 0-2.5 volts Aux Typical sampling rate: 1024 samples/second (with continuous impedance monitoring) Aux Maximum sampling rate: 8192 samples/second (without continuous impedance monitoring) Aux impedance monitoring: 12-bit accuracy, range 10 Megohms Aux Standard Operating Bandwidth: 0.0 (DC) 120.0 Hz. (1024 samples/second internal, 256 samples/second sent to PC) Aux Maximum Operating Bandwidth (4 channels): DC 2048 Hz. (4096 samples/ second internal, 4096 samples/second sent to PC) Aux Maximum Operating Bandwidth (1 channel): DC 4096 Hz. (8192 samples/ second internal, 8192 samples/second sent to PC) Internal Autonomous Functions:Standard Operating rate: 1024 samples or events/second Modes: photic, vibrotactile, auditory feedback Photic: direct real-time EEG-controlled photic stimulation via built-in controller and optional LED glasses Auditory: direct real-time auditory feedback of EEG via. built-in controller and optional earphones or speakers. Vibrotactile: direct real-time tactile feedback of EEG via. built-in controller and optional vibrotactile cushion. Selectable modes: split (L and R separate) or combine (L+R to both eyes/ears/vibro). Requirements 2 GHz processor 512 MB RAM 256 MB of dedicated video memory (if shared memory, 1 Gigabyte minimum RAM) Windows XP (Windows Vista not fully tested, but clients are reporting use)

Directions

Similar products from Non-traditional Medical Treatment

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies