Bs Dental Lab Oral Denture Semi Adjustable Articulator Precision Basic Sysem

US $710

  • China, China
  • Jan 30th
  My eBay items US $0.01 US $24.99 US $4.99 US $0.99 US $429.99 US $47.02 US $23.74 US $0.99 US $55.98 US $11.44 US $0.98 US $37.03 US $29.98 US $24.98 US $18.98 US $39.98 US $26.98 US $12.45 US $22.98 US $15.49 US $0.06 US $68.39 US $52.98 US $24.98 Description   Technical parameters: Condyle ball from the center of 11.28cm Protrusive condylar guide inclination range 15 -60 ° Lateral condyle guide slope adjustment range 0 ° -20 ° Protrusive condylar guide movement arc movement Powell triangle is equilateral triangle Guide plate of the value of the cut 15 ° / 35 ° Excellent waterproof performance Excellent rust resistance Excellent performance replacement parts Replacement magnetic adsorption model Product Code: See label Production: Made in China Made in China Net Weight: 1005g Packing retention: four corners fixed location GM: jaw frame through professional and technical personnel to install calibration, the model can be used across multiple jaw frame. Manufacturing Materials: Material name using the site Copper condyle ball retention before the main pillar inner sleeve cut Cobalt-chromium alloy main activity measure Magnesium alloy other metal parts All engineering plastic parts (wear, pressure is not easy to deform) Non-slip rubber mat down Nylon engineering plastics can absorb trapezoidal plastic plates (anti-wear, easy to change the pressure shocks) Status: Color Black + White Assembled state has assembled Debug debugging status is not accurate ? Basic installation and bonding semi-adjustable jaw holder 1. Check the jaw holder 1.1 Methods 1.1.1 Check the jaw frame parts are complete, and cut the rope fixed jaw holder ?? 1.1.2 check whether the parts screwed 1.1.3 tighten the screw shaft (threaded shaft D25, axle cap D26) 1.2 Notes and prone to problems 1.2.1 Note that the various parts must be tightened 1.2.2 If not tightened, will result in the latter part of debugging is not accurate, so that is not working 1.3 inspection 1.3.1 Use a wrench to check whether screws are fixed 1.3.2 left hand shaking loose jaw holder 1.4 For more prone to problem solving method 1.4.1 Select the external medium and small hexagonal wrench in the accompanying article, tighten 2 Adjust the jaw holder 2.1 Methods 2.1.1 Check the adjustment shaft (D29) is sloshing around, and adjust 2.1.2 Remove the two positioning column (D31), with a small wrench hexagon socket head cap screws loosen slightly, one person hold thimble (D06), a person will be on both sides of the stem (D29) both hands firmly pull it out, to pull them up, and then Hexagon Tighten the screws before loosen thimble, and then plug both sides of the column to locate, check again whether there shaking. 2.2 Notes and prone to problems 2.2.1 Note about adjusting shaft can not shake 2.2.2 If the shaking, when you later use, can cause inaccurate bite 2.2.3 regulation, people hold thimble (D06), a person will be on both sides of the stem (D29) both hands firmly pull it even if you do not Doing so will lead to adjustment shaft from side to side, not accurate. ? 2.2.4 When screwing in the hexagon socket head cap screws should be tightened alternately on both sides, careful not to tighten the side, and then tighten the other side were tight, avoid The degree of tightness on both sides, resulting in inaccurate jaw frame adjustment 2.3 Checking 2.3.1 Hold down the left hand column jaw holder or holders live parts, the right hand and upper jaw holder, shaking his right hand, to see whether the left axis adjustment Right shaking (lower (upper) jaw holder D11, column B D19, column A D13, adjustment shaft D29) 3 Adjust the cutting guide, condylar guide 3.1 Methods 3.1.1 adjust cutting guide: Loosen the screws thimble (D05), the white line thimble (D06) on a scale of 0 to adjust to align, and then screw thimble Tighten the screw; then loosen the screws, which move up and down at the same time, ensure that the thimble is on the vertical dovetail slide (D08) at the bottom of the front end of the mid-point, Then knob (D02) Tighten 3.1.2 adjustable condylar guide: Loosen the screws on both sides of the column (D20), is the head of the regulator 15 straight vertical line and column scale is aligned, and then Tighten the adjustment screws on both sides of the column condylar movement tracks: Loosen the adjusting screws on both sides, so that the head of the vertical adjustment and adjustable head carved 35 degrees straight alignment (this is the average time scale set by the scale, reach maximum specific scale to take the patient's jaw position record To determine, explain in detail later), and then tighten the screws on both sides to adjust Note: Cut pilot scale: 0 ° lateral condyle guide: 15 ° protrusive condylar guide: 35 ° 3.2 Notes and prone to problems 3.2.1 Note thimble with dovetail slide vertically. If you do not vertical, it will lead to later use inaccurate 3.2.2 Note that cut lead to 0. If not 0, jaw plane will change, affecting the accuracy of the functional movement 3.2.3 Note column adjustable head and can not be separated. If the separation is not normal use jaw holder 3.3 Checking 3.3.1 during the visual inspection of our aircraft is able to adjust the jaw properly, bilateral condylar guide locking 3.3.2 maxillary jaw frame without swinging around. 3.3.3 Cut-scale pilot scale at 0; bilateral condylar guide scale 15 scale. 3.3.4 All screws and set screws tightened jaw holder. 3.3.5 maxillary and mandibular sucker stick pan and wait to be sticky area clean. 3.3.6 will be sticky central disk screw holes stuffed. 3.3.7 will be glued jaw jaw plate mounted on a rack placed in the jaw key board with maxillary adsorption key. 3.3.8 Are checks cut by articulating paper guide contact with the plane. 3.3.9 Note: articulating paper thickness of less than 0.3mm. 3.4 for easy solutions to problems 3.4.1 If no thimble and dovetail slide vertically in one hand and loosen the knob, hand held onto the thimble, thimble and dovetail with both hands while adjusting the slider Block horizontal vertical, then tighten the knob 3.4.2 If the cut is not 0 lead in one hand and held onto the thimble holder, loosen the screws thimble, adjust the scale of 0,, thimble thimble tighten the screws 3.4.3 If the adjustable head and column separation, then tighten the screws on both sides of the column, in close contact with the head will adjust the column, and then tighten the screws 4 sticky chin trapezoidal plate preparatory work 4.1 Methods 4.1.1 Remove the screw shaft, and then the jaw frame upside down; large outer hexagonal wrench, screw fixed jaw plate and tighten the center in black base Center hole, place a piece of paper (put glue into the center hole, so as not to spill the glue stick to other parts), closed trapezoidal Disk center hole, the black base of the corresponding frame in the mandibular jaw holder (D11) to see if the fit ? 4.2 Notes and prone to problems 4.2.1 Note the size of the paper block the pad. If too large, trapezoidal base and holder not fit closely, resulting in a fixed bad; if too much paper block Small, you will not achieve the separation of the role of the base and holder 4.3 For more prone to problem solving method 4.3.1 If more than a pad of paper, remove the small paper pad for the block again, check again; if less, then add the paper block 5. Bond jaw holder 5.1 Methods 5.1.1 mixing A, B glue: A glue were removed, B glue amount (the ratio of 1: 1) on a glass plate, mixing with mixing stick 5.1.2 with the proper amount of mixing rods A, B glue around the hole in the holder, painted circle, the calibration column suck black base jaw, jaw on The rack jaw holder (D11), maxillary holder cover, then remove the screw shaft, the jaw holder upside down for 30 minutes, until After AB glue solidified, remove the calibration column 5.2 Notes and prone to problems 5.2.1 Note that the amount of glue AB 5.2.2 is too small, poor adhesion, easy to loose during use, affecting the normal bite 5.2.3 too easy to overflow, easy handling, the next calibration, easy separation of the black base and holder 5.2.4 Note that the length of time to place the coagulation 5.2.5 If the clotting time is too short, when removed, will appear black base with the anchor loose, serious, direct off 5.3 Check 5.3.1 jaw stick rack before checking condylar guide, cut pilot scale is correct; check the black base and the holder is firmly bonded, if you need to remove the Re 5.4 For more prone to problem solving method 5.4.1 When mixing AB glue moderation 5.4.2 If the black base with the anchor loose or fall off, you can not continue to use, you need to remove, clean and clean, and then re-stick Connect Installation 6. jaw trapezoidal plate what effect? Install the lower trapezoid plate is one of the key frame accuracy of the whole jaw. Small errors throughout the jaw holder intentions and no matter how careful we are inevitably arise between the two planes of the jaw, these small errors will shadow Ring to swap function when we later use, so we need to install the jaw in the final frame, the front of all the errors in a return Zero, which is the final approach to the use of an adhesive black trapezoid fixed jaw plate holder on the lower jaw. When the bottom of the ladder frame bonding jaw plate, we want to use jaw frame key. We will pre-cut guide pin to adjust the scale to 0 °, making the upper and lower beams in a parallel state, the next beam at the coated adhesive glue (glue Water usage, see details below), will be bonded trapezoidal panels absorb the jaw frame key, key holder, together with the jaw on the jaw under the trapezoidal plate rack Room, and then the upper jaw and the upper frame key adsorption trapezoidal panels together, so that the entire lower jaw rack keys and trapezoidal plate was adsorbed on the ladder board On, so as to give the glue trapezoidal panels and under the crossbar in the absence of gravity between the oppression of the situation solidified, so the glue will not deform Affect accuracy. After one hour the glue needed to reach the freezing point of gravity can be supported. Note: The bonding process jaw holder, directly affects the jaw holder after use, we recommend should have dedicated staff to be responsible for the bonding jaw holder The work. 7. Check and re-jaw frame bonding 7.1 jaw holder in use for some time, there may be loose, or other circumstances, cause the jaw when the two can not stand each other using Change, this time, the need for inaccurate jaw frame adjustment, adjust the way to remove the black trapezoid lower jaw plate, again in accordance with the The adhesive bonding step. 8. Remove the way down the ladder board 8.1 due to lower trapezoidal panels are bonded on the lower beam, so we can use flat screwdriver in the mouth in front of the trapezoidal plate gap Insert pry pry the lower trapezoidal panels, or dissolving the binder with a dissolving agent.CULATOR S LAB SUPPLIES WAX     FDA STATEMENT | Payment | Shipping | Return | Contact us The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do' ot bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item. PayPal is the good ways to pay. It's fast and safe for buyers. If you are bidding on an online auction, please kindly be serious. Orders will be cancelled and an UPI case will be issue if payments are not received for 4 days by ebay system automatically. Items will be dispatched within 1 business days after payment is fully and clearly received. For orders that are placed on weekends, we will ship them the next Monday. We usually process orders within 1 business days. Please make sure your shipping address is correct when you make the payment. Since we are unable to ship your order to different address other than the shipping address listed in paypal. but if you want to change the shipping address,Please inform us in advance. For international shipping, customs duties might be possible for some countries, they are buyers' responsibility. S&H charged dose not include any those fees. We are not reponsibility for the delay of clearance is the buyer's country, but we will help to clear as suppling some files. If the item is in customs or post office for some days, pls contact with local customs actively, otherwise, if the item returns to us, the buyer will pay for the shipping fee for resend or refund except the shipping fee. The trade is cross-border and Airmail is cheapest shipping way, so it takes a long time for delivery.so we need your understanding for the delivery time, USA:E-packets shipping. About 7-12 business days. UK : 14-45 business days. Canada,Australia: about 14-45 business days; Other European countries: 15-45 business days. South America: 25-45 days. evern more days for some countries. However, if you want more fast shipping you can pay the items by EMS, UPS,TNT,Fedex and DHL.Please contact us for freight fee. The package will be marked as gift or sample for personal use with a small value, so you don't need to worry about the custom or tax issues. Our return and refund policy can ensure your satisfication if any problem encountered. 14 Days Return Buyers can return their item back to us for exchange during 7 to 14 days after receiving the item. If not quality problem was found, buyer will be responsible for the shipping cost of round trip. 1 Year Warranty Items bought from us enjoy warranty of 1 year for the main device. For acessories, the period is 3 month. During warranty, we can supply repair service free but buyer will pay for the shipping cost. Please Be Advised: Artificial damage will not be covered by warranty. All accessories should be all collected when returning back to us, otherwise the price difference will be charged to buyer. If you encountered any problem in using the item, please kindly contact us at the first time. We believe that every problem could be solve by communicating with us. Leaving a negative feedback will be a great shock on our enthusiasm in serving you better. Communication is the best way to achieve WIN-WIN. If you have any question,please contact me with ebay message. I
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand BS
Country/Region of Manufacture China
Model S-M

Directions

Similar products from Facebows & Articulators

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies