Ce Fda Multi Parameters Icu/ccu Vital Signs Hot Patient Monitor Cms7000,popular

US $779.00

  • qinhuangdao, China
  • Jun 9th
Contec Medical System is an original equipment manufacturer (OEM) specialized in patient monitor, pulse oximeter, ECG, ECG Holter, EEG, EMG/EP, Stethoscop, etc. Worldwide distributors are warm welcomed. Join Us Now! Any question or comment is welcomed! Just feel free to contact me by the following ways: Contact person: Mary liang Email&MSN: contec.med.mary@hotmail.com Office TEL: 0086-335-8015561   CE&FDA New 6 parameter Patient Monitor ECG, Spo2, NIBP, Rulse Rate ,Temp, Resp CMS7000   Instructions This equipment can monitor such parameters as ECG, RESP, SpO2, NIBP, and Dual- channel TEMP. It integrates parameter measuring module, display and recorder in one device to form a compact and portable device. At the same time, its built-in replaceable battery provides convenience for patient moving.   Major Features ? Elegant appearance, clear marks, standard interface, oxyCRG SCREEN, trend graph, big        characters, other BED observation, which are convenient for user. ? Be applicable for adult, pediatric and neonatal. ? Standard parameters of ECG, RESP, NIBP, SpO2 and dual-channel TEMP. IBP, CO2, Built-in      printer, curving handle, moving bracket and hanging bracket are optional. ?  Operation interface with Chinese and English. Finish all operations by keys and knobs.     (Optional languages: French, German, Italian, Dutch, Portuguese, Turkish, Spanish,      Poland.) design with full built-in module, stable and reliable performance. ?  12.1'' color TFT LCD with high-resolution displays patient parameter and waveform, and       alarm, bed NO, clock, state and other information provided by the monitor synchronously.      Monitoring contents, scan speed, volume and output contents can be set optionally. ? Storage of 480-hour trend data, and review of 40-second holographic waveform. ? Storage and review of 72-hour ECG waveform. ? Function of NIBP review, storage for up to 2400 NIBP data. ? Adopt digital SpO2 technology, which has strong anti-interference and anti-weak filling    capability. ? Calculation of drug concentration. ? Network: connecting with central station, other Bed observation and software updating.      Connection mode: wireless and wired. ? Built-in rechargeable battery for uninterrupted monitoring. ? Print ECG, SpO2, RESP, BP and temperature data with one-key. ? Anti-high frequency surgical unit, defibrillation-proof(requirement for special leads). ? Analysis function for heart rate variability(HRV) (optional)   Main performance ECG ? Lead Mode  5-lead are optional ? Lead Selection I, II, III, avR, avL, avF, V ? Wave 5-lead: 2 channels ? 3-lead: 1channel ? Gain x2.5mm/mV, x5.0mm/mV, x10mm/mV, x20mm/mV ? HR Measuring and Alarm Range ? Range 15 ~ 300 bpm ? Accuracy ±1% or ±1bpm, which is greater ? Alarm Accuracy ±2bpm ? Resolution 1 bpm CMRR ? Monitor >= 100 dB ? Surgery >= 100 dB ? Diagnosis >= 60 dB Bandwidth ? Surgery 1 ~ 20 Hz(+0.4dB,-3dB) ?Monitor 0.5 ~ 40 Hz(+0.4dB,-3dB) ? Diagnosis 0.05~75Hz(+0.4dB,-3dB); 76Hz~150Hz(+0.4dB,-4.5dB) ? Calibration Signal 1 mV (Vp-p), ±5%  Accuracy ST Segment Monitoring ? Measuring and Alarm Range -0.6 mV~ + 0.8 mV ARR ? ARR Detecting Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY,  R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC ? Alarm Available ? Review Available ? Scan Speed for ECG Waveform is adjustable: ? 12.5mm/s accuracy ±10% ? 25mm/s accuracy±10% ? 50mm/s accuracy±10% ?Respiration ? Method R-F(RA-LL) Impedance ? Differential Input Impedance >2.5 M? ? Measuring Impedance Range 0.3~5.0? ? Baseline Impedance Range 100?– 2500? ? Bandwidth 0.3 ~ 2.5 Hz ? Resp. Rate ? Measuring and Alarm Range 0~120rpm ? Resolution 1 rpm ? Measuring Accuracy ±2 rpm ?Alarm Accuracy ±3rpm ? Apnea Alarm 10 ~ 40 S NIBP ? Method Oscillometry ? Mode Manual, Auto, continuous ? Measuring Interval in AUTO Mode 1 /2 /3 /4 /5/ 10/ 15/ 30 /60 /90/120/240/480/960 Min ? Measuring Period in Continuous Mode 5 Min ? Measuring and Alarm Range 10~270mmHg ? Alarm Type SYS, DIA, MEAN ? Resolution: ? Pressure 1mmHg ? Cuff Pressure ±3 mmHg ? Accuracy ±10% or ±8mmHg, which is greater ? Over-pressure Protection: ? Adult Mode 315±10 mmHg ? Pediatric Mode 265±10 mmHg ? Neonatal Mode 155±10 mmHg SpO2 ? Measuring Range 0 ~ 100 % ? Alarm Range 0 ~ 100 % ? Resolution 1 % ? Accuracy 70% ~ 100% ±2% 0% ~ 69% unspecified ? Pulse Rate(PR) ? Measuring and Alarm Range 0~250bpm ? Resolution 1bpm ? Measuring Accuracy ±2bpm or ±2%, which is greater ? Alarm Accuracy ±2bpm TEMP ? Channel dual-channel ? Measuring and Alarm Range 0 ~ 50°C ? Resolution 0.1°C ? Accuracy ±0.1°C ? Actualization Interval about 1 Sec. ? Average Time Constant < 10 Sec. ?Alarm responding Time
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand Contec
MPN Does Not Apply
Model CMS7000
Country of Manufacture China

Directions

Similar products from Health Condition Monitors

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies