Contec 100% Warranty Icu Patient Monitor Ecg Nibp Spo2 Pulse Rate Cms6000,ce Fda

US $340

  • Qinhuangdao, China
  • Jan 30th
Multi-4 Parameter Patient Monitor (ECG,NIBP,SPO2,Pulse  Rate)  Model: CMS6000A Description CMS6000A   Multi-4 Parameter Patient Monitor (ECG,NIBP,SPO2,Pulse Rate) Specification: Classification  The type of protection against electroshock:Class I  equipment, and internally powered equipment EMC:Class A The  degree of protection against electroshock: Type CF applied part The  degree of protection against ingress of water: IPX0 Dimension and  weight Dimension : 230 x 133 x 220(mm) Net weight :  2.6kg Display Color TFT LCD 8 inch display Resolution: 800 x 600  Working performance  Waveform  ECGI, ECGII, PLETH, RESP, ETCO2, 2 IBP Time for trend review   480-hour User interface Multilevel menu for selecting, and can  connect with central monitoring station Features ? 8.4? color TFT display ? Suitable for adult, pediatric and neonatal patient   ? Basic parameters (ECG, SpO2, NIBP) in a durable case for bedside monitoring and transport     ? Audible and visual alarms with adjustable alarm ranges   ? Networkable with CONTEC  central monitoring system   ? Powerful data management and storage capacity ECG ? Lead type:5-lead   ? Input: RA; LA; RL; LL; V   ? Sweep speed: 12.5mm/s, 25mm/s, 50mm/s   ? Accuracy: ±1bpm or ±1%, whichever is greater   ? Protection: Withstand 4000VAC/50Hz voltage in  isolation against electrosurgical and defibrillation   ? S-T detection: YES, Arrhythmia analysis: YES   ? Alarm: YES, audible and visual alarm, alarm events recallable NIBP Measuring method Oscillometry Measuring range a)Systolic: 40mmHg~270mmHg(adult)          40mmHg~200mmHg(pediatric)          40mmHg~135mmHg(neonatal) b)Diastolic: 10mmHg~215mmHg(adult)           10mmHg~150mmHg(pediatric)           10mmHg~100mmHg(neonatal) Cuff inflation  <30s(10~270  mmHg, standard adult cuff) Measuring Period  Average<40s Measuring Interval in AUTO Mode  1, 2, 3, 4, 5,  10, 15, 30, 60, 90,120, 240, 480 min. Accuracy  ±10% or ±8mmHg, which  is greater ? Method: Oscillometry   ? Operation modes: Manual/Automatic/STAT     ? Measurement unit: mmHg/KPa selectable   ? Measurement types: Systolic, Diastolic, Mean     ? Over-pressure protection: YES  SPO2 Oxygen  Saturation(SpO2) The percentage of HbO2 in the total Hb in the  blood Measuring range 0~100% 0%~69% unspecified Accuracy ±2bpm or ±2%, whichever is  greater Resolution 1% Upper and lower limit for  alarm 0%~100%, error: ±2% Pulse rate(PR) 0~250bpm Upper  and lower limit for PR alarm  0bpm~250bpm, error: ±2bpm ? Measurement range: 0-100%   ? Accuracy: ±2digit (70~100%);     ? 0~69% unspecified Power supply  DC 9V 220V, 50Hz Pmax: 150VA RESPIRATION (optional) Measuring Method Impedance Measuring Range Adult  0~120rpm Pediatric and Neonatal   0~150rpm Measuring Accuracy  ±2 rpm Apnea Alarm  10 ~ 40 S Scan Speed  6.25mm/s, 12.5mm/s, 25 mm/s TEMP(optional) Channel dual-channel Measuring Range 0~50(°C) Accuracy ±0.1°C Resolution 0.1°C Temperature (optional) Working: 5~40(°C) Storage and transportation: -40~+55(?C) Humidity Working: 30%~75% Storage and transportation:
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand Contec

Directions

Similar products from Health Condition Monitors

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies