Dale 601e 601 Electrical Digital Safety Analyzer

US $990

  • Casselberry, Florida, United States
  • Oct 27th
This item is used in good working condition, With large user manual carrying case and all cables. Overview The DALE601 measures Line Voltage, Instrument Current, Ground Resistance, Earth and Chassis Leakage Current, Patient Lead-to-Ground, Lead-to-Lead and Lead Isolation (M.A.P.) Current, External Gradient, Probe and Transducer Isolation Current and Point-to-Point Resistance. DALE601 also tests all 120-volt standard wall outlets for proper wiring. The green and amber light indicate five normal or fault conditions. Unique to the DALE601is its capability to make a broad range of external measurements. A clearly labeled single master function switch guides the user through a complete measurement procedure. Heavy-duty switches change polarity, open and close the neutral and select Chassis or Earth Leakage Current measurements. A four-wire Kelvin bridge eliminates reading errors in resistance due to cable length and contact resistance. True RMS measurements are provided for all current readings. The AAMI test load is utilized. The DALE601 has five (5) universal EKG lead connectors that allow for any type of lead connection.There is also a single slide switch that gives the user a choice of AAMI or IEC test load. Features Small, lightweight, self-contained portable instrument Master range meter delivers accurate measurement for each test Accurate test measurements with 4-wire Kelvin bridge Test method complies with AAMI load per ANSI/AAMI ES1-1993 or IEC601-1 Leakage Current can be measured in Open/Closed Neutral, Normal/Reversed Polarity and Open/Closed Ground All Leakage Current measurements are displayed directly in µAmps. Broad range of external measurements Five (5) Universal EKG Lead Connectors The DALE601 is designed for 120 V operation Specifications Mains Voltage 117 Volts, 50/60 Hz Instrument Current Range: 0 - 19.99 Amps Resolution: 10 mA Accuracy: 5 % R Ground (Earth) Resistance Range: 0 - 1.99 Accuracy: 1% R ± 1 LSD 2 - 19.99 Accuracy: 2 % R ± 1 LSD Resolution: 10 mOhms Leakage Current Range: 0 - 1, 999 µA Accuracy: DC & 25 Hz - 1kHz: ±1% of reading, ± 3LSD 1.0KHz - 100 KHz: ±2.5% of reading, ± 3LSD 100 KHz - 1 MHz: ±5% of reading, ± 3LSD Type Measurement: True RMS Test Load: AAMI or IEC601-1 (selectable) Current Consumption Range: 0-14.99A(Dale 601-1515) 0-19.99A(Dale 601-1520/2020) 0-9.99A(Dale 601E) Current Capacity Dale 601-1515 15Amps Dale 601E 10Amps Dale 601-1520/2020 20Amps, 20% duty cycle (2 minutes on, 8 minutes off) Controls 1. Function Switch - 9 position rotary 2. Lead Switch - 6 position rotary 3. Neutral Switch - 2 position rocker (Open/Closed) 4. Polarity Switch - 3 position rocker (Normal/Off/Reversed) 5. Leakage Switch - 2 position rocker (Chassis/Earth) DUT Power 117 VAC, 16 Amps@ 120 V, 10 Amps @ 230 V Physical Size 4.0 x 7.8 x 1.6 inches (102 x 196 x 41 mm)

Directions

Similar products from Digital Signal Level Meters, Video Analyzers and Other Television Test Equipment

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies