Dental Implant Pointer (implant Detector)

US $490.00

  • Dangjin-si, Chungcheongnam-do, Korea, South
  • Jun 9th
                                 The Implant Pointer is A Friendly Dentistry Instrument Precise spotting & detecting implants buried under soft tissues   Operating the Unit: 1. Turn the Unit on by inserting the Sensor (with the Protective Cover on it) so that the notice “TOP SIDE” faces in the same direction as the logo “CTI” on the Battery Cover. 2. The bottom side of the Sensor should be gently clasped to the gum in the area intended for the implant. 3. The Sensor should be slowly moved along the gum, keeping it in constant contact with the gum. 4. When the LED turns from Blue to Green, the sensor is close enough to the Implant. 5. Keeping the Sensor exactly above the found Implant, insert the tip of the Marker into the hole in the center of the Sensor and mark the Implant position by pushing the Marker into the gum, simultaneously twisting it several times for better marking.  6. Reset the last found implant parameters by bringing the Sensor close to any metal object such as the Marker Handle and keep it attached to the Handle until the indicator switches from Blue to Yellow, then take it away. The LED will switch back to Blue, indicating that the Unit is ready to be used again.   After Using the Unit 1. Turn the Unit off by extracting the Sensor. 2. Remove the Protective Cover. 3. Twist off the Marker from the Marker Handle.  4. Dispose of the used Sensor, Protective Cover and Sensor.    Sterilization 1. The Marker Handle should be autoclaved at 135C (249.8F), for a minimum of 4 minutes with a sterilization pouch. Minimum Drying Time after sterilization: - 10 minutes.  2. Sterilize the surface of the Unit by wiping it with a piece of gauze dampened with Ethanol for Disinfection (Ethanol 70~80%). Wring the gauze out to make sure it is not too wet.   Storage in the clinic Keep the Unit, the sterilized Marker Handle and the Disposable Sets in the closed Kit Box.   Working Life The Working Life of this equipment is at least 6 years from the date of shipment, provided it is regularly and properly inspected and maintained.   Technical Specifications: Power Source - 1.5 V (One AA Alkaline Battery) Rated Current max - 0.04 A Power Consumption max - 0.06 VA Dimensions - 170 mm :: 24 mm Weight - 50 g   https://www.youtube.com/channel/UCZvbBUVPSTf4j1EnnPh7swA Best indication for Implant Pointer : Asymmetry implant position For overdenture   Shipping Information Worldwide Shipping: International Delivery time 3-5 working days.(Shipping by EMS)
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand CTI-AMP
Model dIP004

Directions

Similar products from Other Oral Health Equipment

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies