Despatch Pnd2-29-21e Inert Atmosphere Oven/chamber

US $9,499.99

  • Phoenix, AZ, United States
  • Jan 30th
Despatch PND2-29-21E Inert Atmosphere Oven/Chamber Comes with a copy of the manual and what you see in the pictures. If you don't see it, you probably wont get it. Specifications are from Despatch and may vary slightly due to upgrades, options or revisions this unit may or may not have. This oven was removed from service working and designed for Intel. We will demo this oven upon request. Guaranteed to run. Design Information and Specification Tag Says: Serial Number: 158998 Designed For: Intel Use of Equipment: Industrial Heating Amount of Product: Varies Heating Time: Varies Max. Operating Temeprature: 343°C (650°F) F.A. Duct: None Exh. Duct: Pressure Relief F.A. Damper Blade Cut To: None Exh. Damper Blade Cut To: None Minimum Purge Time Required: 0 minutes Type of Solvent (Flammable Liquid or Gas): None Maximum Amount Allowed: None Design Specifications Tag Says: Serial Number: 158998-L Model: PND2-29-21E Normal Operating Temperature: N/A Max. Operating Temperature: 650°F (343°C) Heater Type: Electric Heater Capacity: 36 KW - Split 1/3-2/3 Banks Heater Amps: 14.4 A/28.8 A Largest Motor Amps: 7.5 A Total Motor Amps: 7.5 A Control Voltage: 24/120 V, 1 PH, 60 Hz Line Voltage: 480V, 3 PH, 60 Hz Gas Supply Pressure: N/A PN Series Inert Atmosphere Ovens: The PN Series Inert Atmosphere Ovens are designed to accomodate a wide variety of processes where an inert atmosphere is required to prevent product oxidation. Typical applications include curing, bonding and heat treating. Despatch provides the design integrity, manufacturing experience and emphasis on quality necessary for dependable operation and excellent process control. Standard Features: Sold state heater control provides precise temperature control for consistently high process results. Stainless steel interiors for highly corrosive conditions or where interior cleanliness is critical. Chamber pressure gauge. Swing out front panel allows control access for ease of maintenance. FM approved hi-limit overtemperature protection to minimize risk of equipment or product damage. Oven interior continuously welded to prevent atmosphere leakage. Special doors, with tight fitting gaskets allow contraction and expansion at higher temperatures and prevent atmosphere leakage. Adjustable purge and maintain flowmeters, valves and timers for automatic inert gas control. Heat exchanger provides rapid cool-down or the ability to operate at low temperatures within a sealed chamber. (Air-to-water for 650°F model) Standard set-up for two shelves adjustable on 3" centers. U.L. listed control panel. Many local authorities will readily approve equipment that has a U.L. panel. Special Features with this Unit (from the manual): PROTOCL programmable temperature controller/hi-limit controller, MRC 7000 programmable circular chart recorder/hi-limi controller, numerous safety features. Unique Despatch design to combine higher fan volume of forced recirculated air with a system of perforated stainless steel walls for the ultimate in temperature uniformity. Back welded double wall construction and fiberglass insulation to reduce heat loss. Silicone rubber gaskets further minimize heat leakage. Rapid response heater Scracth-resistant baked enamle exterior and stainless steel interior for easy cleaning. Adjustable flowmeters for oxygen free performance, Water cooling to cool loads quickly or to operate at low temperatures within the sealed chamber, Main line disconnect switch with lockout and tagout features. The lockout and tagout should be used any time maintenance is performed out of sight of the main line disconnect switch. The switch is located on the control panel. Options: Programming controls for controlling rate of temperature rise and processing timing functions. Records - 10 inch diameter round chart. Alarms, audible and visual to signal end of process or other events. Door lock to prevent opening door during cycle to assure process is not interrupted. Unit has more options as well!!!! Oven Specifications: Maximum Temperature: 650°F (343°C) Work Chamber Dimensions:   Width: 37" (940 mm)   Depth: 23" (58 mm)   Height: 37" (940 mm)   Capacity Feet: 21.0 feet3 (595 liters) Maximum Number of Shelf Positions: 3 Overall Dimensions:   Width: 82" (2083 mm)   Depth: 53" (1346 mm)   Height: 72" (1829 mm) Distance From Floor to Work Opening: 30" (762 mm) Heater Capacity: 36KW Recirculating Fan System:   Motor HP: 5   CFM: 2700 Time to Temperature (approximte minutes with no load):   25°C - 100°C: 5   25°C - 200°C: 15   25°C - 300°C: 30 Recovery Time Door Open 1 Min. (approximate minutes with no load):   100°C: <1   200°C: 2   343°C: 7 Minimum Operating Temperature1 (Approximate w/20°C ambient):   with water cooling: 5°C   without water cooling: 100°C Control Stability: +/- 0.3°C Repeatability: +/- 0.5°C Cooldown Time (approximate minutes with no load):   30°C - 60°C3: 752 Maximum Shelf Load: 180 lbs. (standard is 130) Maximum Load Capacity: 540 lbs. (standard is 350) Shipping Weight (Approximate): 2000 lbs. (907 kg.) Body: 18 gauge interior and exterior Finish: Exterior - Light gray baked enamel. Interior - optional stainless steel and aluminized steel Insulation: 5" Utility Requirements:   208 Volts, 118.1 Amps, 60 Hz, 3 Phase, 36 Heater KW   415 Volts, 60.4 Amps, 50 Hz, 3 Phase, 36 Heater KW   480 Volts, 52.1 Amps, 60 Hz, 3 Phase, 36 Heater KW (unit is wired for this) Utility Requirements for Controls: 24/120 Volts, 1 Phase, 60 Herz 1 Minimum operating temperature will vary with respect to inert gas flow and temperature 2 60°F water temperature at 210 GPH 3 Figures are based on actual tests with 45 loaded 3.1 inch wide magazines Despatch/Partlow MRC7000 Control/Chart Recorder Description: The instrument is a microprocessor based circular chart recorder capable of measuring, displaying and recording from a variety of inputs. Applications include temperature, pressure, flow and others. The instrument can be specified as either a singal or dual pen unit. Recording, alarm or limit settings and other parameters are easily entered via the keypad. All user data can be protected from unauthorized changes by the Enable Mode security system, and is protected against memory loss, as a result of AC power outage, by battery back-up. The process variable input for each terminal is user configurable to directly connect to either thermocouple, RTD, mVDC, VDC, or mADC inputs. Changes in input type can easily be made by the user. Thermocouple and RTD linearization, as well as thermocouple cold junction compensation, is performed automatically. The instrument process variable inputs are isolated. An isolated 24 VDC regulated transmitter power supply can be provided in the instrument for use with up to two 4 to 20 mADC sensor transducers. Link to more images - High quality pictures, may take awhile to load.: Up Close Pictures of the Control Panel Up close Pictures of Various Other Devices on the Machine (Configuration/Setup) Up Close Pictures of the Specifications/Design/Serial Tag and Door Latch with the Panel Removed $250.00 Packaging, palletizing, and loading. Shipping to be determined by destination. If you have any questions please email us at: ebay@mhzelectronics.com or call Michael at 1-866-MHZ-ELEC (1-866-649-3532) Toll Free. Also, please click here to view or other auctions! 12/10/04 Powered by eBay Turbo Lister The free listing tool. List your items fast and easy and manage your active items. On Oct-31-13 at 21:12:43 PDT, seller added the following information: Click Here. Double your traffic. Get Vendio Gallery - Now FREE!

Directions

Similar products from Burn-in Power Supplies & Other Equipment

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies