Drager Sensor Xs Nh3 Drager 6809145 X-am 7000, Pac Iii, Miniwarn

US $150.00

  • Kiev, Ukraine
  • Feb 20th
DragerSensor® XS NH3 P/N 6809145 For Drager; X-am 7000, Pac III, MiniWarn & Multiwarn II Monitors Gases qualified to measure: Ammonia (NH3) Compatible Instruments: X-am 7000, Pac III, MiniWarn & Multiwarn II Monitors Measuring Range: Maximum: 0 to 200 ppm NH3 Standard: 0 to 200 ppm NH3 Minimum: 0 to 50 ppm NH3 Response Time: 50% response to exposed concentration in less than 20 seconds, or Alarm at TLV when exposed to 5x TLV in less than 10 seconds Accuracy: +/- 3% of Maximum Full Scale Value or better Display Resolution: 1 ppm Environmental Conditions: Temperature: -40 to 122 °F (-40 to 50 °C), continuous operation -40 to 140 °F (-40 to 60 °C), short duration The service life can be reduced by high temperature. Humidity: 10 to 95 %RH, continuous operation 5 to 99 %RH, short duration Pressure: 20.7 to 38.4 inches Hg (700 to 1300 mbar) Note: Rapid changes in environmental conditions may cause temporary fluctuations on the sensor readings Cross-Sensitivities: Positive Effects: H2S, PH3, NO, HCN, SO2, and Methanol Negative Effects: Cl2, NO2 and CO2 Note: Other gases may have an influence on the sensor Calibration Frequency: Required: 6 months Recommended: 3 months Calibration Gas: Required: Ammonia Concentration: 40-100% of selected range Minimum: 10 ppm Compatible Filters: Internal Dust & Mist Filter: P/N 6809021 (provided with sensor) Warranty Period: 1 Year DragerSensor XS There are currently 25 different XS sensors available that can measure over 50 different gases and vapors. XS stands for “eXtra Stability”, meaning these sensors require less frequent calibration than competitive sensors. XS sensors are intelligent sensors that can be interchanged between the Pac III, Pac Ex 2, MiniWarn, Multiwarn II, and Drager X-am 7000 monitors. All sensor-related data, including measuring ranges, calibration, alarm set points, etc., are stored in the sensor memory and transferred to the next instrument. XS sensors include advanced technical features such as internal temperature compensation, outstanding pressure compensation, and user-changeable internal cross-sensitivity filters. These improvements provide more accurate measurements than other brands. The CO, H2S and O2 versions of the XS sensor carry a 3-year warranty and only require calibration on an annual basis.
Condition:
New other (see details): A new, unused item with absolutely no signs of wear. The item may be missing the original packaging, or in the original packaging but not sealed. The item may be a factory second or a new, unused item with defects. See the seller’s listing for full details and description of any imperfections. ...
Brand Drager
Country/Region of Manufacture Germany
Model 6809145

Directions

Similar products from Gas Alert Clips & Gas Monitors

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies