Fluke 116 323 Hvac Combo Kit *new* Msrp $335

US $274.99

  • Haymarket, Virginia, United States
  • Jun 9th
 Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter       Unit is *NEW* in Box Having the right tool for the job is essential. Having all the right tools when you need them is even better. The Fluke 116/323 HVAC Combo Kit gives you the best in a versatile, rugged multimeter and a fast-acting, general purpose clamp meter.   Fluke 116 HVAC Multimeter Built-in thermometer for HVAC applications Microamps to test flame sensors Low input impedance helps prevent false readings due to ghost voltage Work in poorly lit areas with the Large white LED backlit display True-rms voltage and current for accurate measurements on non-linear loads Measures 10 A directly (20 A overload for 30-seconds) without a current clamp Resistance, continuity, frequency and capacitance Record signal fluctuations using Min/Max/Average and elapsed time stamps Easy to use with one hand Hands free operation with optional magnetic hanger (ToolPak™) CAT III 600 V safety rated Fluke 323 True-rms Clamp Meter. Rugged. Reliable. Precise. 400 A ac current measurement. 600 V ac and dc voltage measurement. True-rms ac voltage and current for accurate measurements on non-linear signals. Resistance measurement up to 40 k? with continuity detection. Slim, ergonomic design. CAT IV 300V/CAT III 600 V safety rating Specifications Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Display 6,000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Operating Temperature -10 °C to + 50 °C Storage Temperature -40 °C to + 60 °C Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery Life 400 hours typical, without backlight Accuracy Specifications DC millivolts Range/Resolution 600.0 mV / 0.1 mV Accuracy ± ([% of reading] + [counts]): 0.5% + 2 DC volts Range/Resolution 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V Accuracy ± ([% of reading] + [counts]): 0.5% + 2 Auto volts Range 600.0 V / 0.1 V Accuracy 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) AC millivolts1 True RMS Range 600.0 mV / 0.1 mV Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) AC volts1 True RMS Range/Resolution 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) Continuity Range 600 ? / 1 ? Accuracy Beeper on < 20 ?, off > 250 ?; detects opens or shorts of 500 ?s or longer. Ohms Range/Resolution 600.0 ? / 0.1 ? 6.000 k? / 0.001 k? 60.00 k? / 0.01 k? 600.0 k? / 0.1 k? 6.000 M? / 0.001 M? Accuracy 0.9 % + 1 Range/Resolution 40.00 M? / 0.01 M? Accuracy 1.5 % + 2 Diode Test Range/Resolution  2.000 V / 0.001 V Accuracy  0.9% + 2 Capacitance Range/Resolution 1000 nF / 1 nF 10.00 ?F / 0.01 ?F 100.0 ?F / 0.1 ?F 9999 ?F / 1 ?F 100 ?F to 1000 ?F Accuracy 1.9% + 2 Range/Resolution > 1000 ?F Accuracy 5% + 20% LoZ capacitance Range 1 nF to 500 ?F Accuracy 10% + 2 typical Temperature2 (Type-K thermocouple) Range/Resolution -40 °C to 400 °C / 0.1 °C Accuracy2 1% + 10 Range/Resolution -40 °F to 752 °F / 0.2 °F Accuracy2 1% + 18 AC ?amps true-rms (45 Hz to 500 Hz) Range/Resolution 600.0 ?A / 0.1 ?A Accuracy 1.0% + 2 DC ?amps Range/Resolution 600.0 ?A / 0.1 ?A Accuracy 1.0% + 2 Hz (V or A input)2 Range/Resolution 99.99 Hz / 0.01 Hz 999.99 Hz / 0.1 Hz 9.999 Hz / 0.001 Hz 50.00 Hz / 0.01 Hz Accuracy 0.1% + 2 Notes: 1 All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V. 2 Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. • Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current. • Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F. Mechanical and General Specifications Size 167 x 84 x 46 mm (6.57" x 3.31" x 1.82") Weight 550 g Warranty 3 years   Fluke 62 MAX+ Infrared Thermometer Specifications Temperature range -30 °C to 650 °C (-22 °F to 1202 °F) Accuracy ±1.0 °C or ±1.0% of reading, whichever is greater -10 °C to 0 °C: ±2.0 -30 °C to -10 °C: ±3.0 Response time (95%) <300 ms (95% of reading) Spectral response 8 to 14 microns Emissivity 0.10 to 1.00 Optical resolution 12:1 (calculated at 90% energy) Display resolution 0.1 °C (0.2 °F) Repeatability of readings ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater Power AA battery Battery life 8 hours with laser and backlight on Physical Specifications Weight 255 g (8.99 oz) Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches Operating temperature 0 °C to 50 °C (32 °F to 122 °F) Storage temperature -20 °C to 60 °C (-4 °F to 140 °F), (without battery) Operating humidity 10 % to 90 % RH non-condensing at 30 °C (86 °F) Operating altitude 2000 meters above mean sea level Storage altitude 12,000 meters above mean sea level IP rating IP 54 per IEC 60529 Drop test 3 meters Vibration and shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms EMC EN 61326-1:2006 EN 61326-2:2006 Standards and agency approval Compliance EN/IEC 61010-1: 2001 Laser safety FDA and EN 60825-1 Class II
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand Fluke
Country/Region of Manufacture United States
Model 116/323
MPN 116-323

Directions

Similar products from Electrical Tool Sets & Kits

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies