Fluke 1625 Advanced Earth Ground Tester Geo Kit 1625kit

US $2,495.00

  • Toledo, Ohio, United States
  • Jan 29th
                                                              Content on this page requires a newer version of Adobe Flash Player.                      The Following Items Are Included: Fluke 1625 Advanced Earth / Ground Tester Geo (BC# 15776)  Fluke El-162X Sensing Current Transformer Fluke El-162AC Inducing Current Transformer 25 Meter Cable Reel 50 Meter Cable Reel 2-3 Wire Adapter P/N: C688353A 1623/25 Probe Cable Flexible Test Leads (1-Red, 1-Black) (2) Alligator Clips (3) Earth Ground Stakes Hard Copy User Manual Hard Carrying Case (G)     BE SURE TO CHECK OUR EBAY STORE FOR OTHER ITEMS! This Item Has A Current Calibration!   Fluke 1625 Advanced Earth / Ground Tester Geo Kit   Automatic Frequency Control (AFC) – identifies existing interference and chooses a measurement frequency to minimize its effect, providing a more accurate earth ground value.   Includes Hard Carrying Case & Accessories As Listed Above!     Working Condition: Excellent Condition: Refurbished Calibrated: Yes Warranty: 90 Day Exchange Warranty     The Fluke 1625 is distinctive earth ground testers that can perform all four types of earth ground measurement. Specifically, the Fluke 1625 tester is able to measure earth ground loop resistances using only clamps – called Stakeless testing. This method doesn’t require the use of earth ground stakes or the disconnection of ground rods. Testing Methods 3- and 4-Pole Fall of Potential – standard earth ground testing using two ground stakes Selective testing – without disconnecting ground rods, a technician can measure ground resistance using a combination of stakes and a clamp. Stakeless testing – innovative solution using only clamps, instead of ground stakes, to measure earth ground loop resistance. The Fluke 1625 offers these advanced features Automatic Frequency Control (AFC) – identifies existing interference and chooses a measurement frequency to minimize its effect, providing a more accurate earth ground value. R* measurement – calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to-earth ground would see. Adjustable limits – for quick test result verification. Features: 3- and 4-pole earth ground measurement 4-Pole soil resistivity testing 2-pole resistance measurement AC 2- and 4-pole resistance measurement DC Selective testing, no disconnection of ground conductor (1 clamp) Stakeless testing, quick ground loop testing (2 clamps) Earth impedance measurement at 55 Hz Automatic frequency control (AFC) (94, 105, 111, 128 Hz) Measuring voltage switchable 20/48V Programmable limits, settings Continuity with buzzer     Specifications: RA 3-pole ground resistance measurement (IEC 1557-5) Measuring Voltage  Vm = 20/48 V ac Short circuit current  250 mA ac Measure frequency  94, 105, 111, 128Hz Resolution  0.001 ? to 100 ? Measuring range  0.001 ? to 299.9 k? Intrinsic error  ± (2 % of reading + 2 d) Operating error  ± (5 % of reading + 5 d) RA 4-pole ground resistance measurement (IEC 1557-5) Measuring Voltage  Vm = 20/48 V ac Short circuit current  250 mA ac Measure frequency  94, 105, 111, 128Hz Resolution  0.001 ? to 100 ? Measuring range  0.001 ? to 299.9 k? Intrinsic error  ± (2 % of reading + 2 d) Operating error  ± (5 % of reading + 5 d) RA 3-pole ground resistance measurement with current clamp Measuring Voltage  Vm = 20/48 V ac Short circuit current  250 mA ac Measure frequency  94, 105, 111, 128Hz Resolution  0.001 ? to 10 ? Measuring range  0.001 ? to 29.99 k? Intrinsic error  ± (7 % of reading + 2 d) Operating error  ± (10 % of reading + 5 d) RA 4-pole selective ground resistance measurement with current clamp Measuring Voltage  Vm = 20/48 V ac Short circuit current  250 mA ac Measure frequency  94, 105, 111, 128Hz Resolution  0.001 ? to 10 ? Measuring range  0.001 ? to 29.99 k? Intrinsic error  ± (7 % of reading + 2 d) Operating error  ± (10 % of reading + 5 d) Stakeless ground loop measurement Measuring Voltage  Vm = 20/48 V ac Measure frequency  94, 105, 111, 128Hz Noise current (Iext)  Max. Iext = 3 A Resolution  0.001 ? to 10 ? Measuring range  0.001 ? to 29.99 k? Intrinsic error  ± (7 % of reading + 2 d) Operating error  ± (10 % of reading + 5 d) Environmental Specifications Working temperature  -10 °C to +50 °C Operating Temperature  0 °C to +35 °C Nominal temperature  +18 °C to +28 °C Storage Temperature  -30 °C to +60 °C Climatic class  C1 (IEC 654-1), -5 °C to + 45 °C, 5 % to 95 % RH Protection type  IP56 for case, IP40 for battery door according to EN 60529 Safety Specifications Safety Rating  CAT II, 300 V Mechanical & General Specifications Display  2999 Digit LCD – 7 segment liquid crystal display with special symbols and backlight Size  133 mm x 187 mm x 250 mm Weight Fluke 1623 + 1625  1.1 kg (including batteries) Warranty  90 Days Battery Life  Typical 3000 measurements (RE+RH
Condition:
Seller refurbished: An item that has been restored to working order by the eBay seller or a third party not approved by the manufacturer. This means the item has been inspected, cleaned, and repaired to full working order and is in excellent condition. This item may or may not be in original packaging. See the seller’s listing for full details. ...
Brand Fluke
Model 1625

Directions

Similar products from Other Measuring Devices

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies