Fluke 199b Scopemeter 2.5gs/s Dual-input 200mhz Handheld Oscilloscope 199/003

US $1,695.00

  • Toledo, Ohio, United States
  • Mar 7th
                                                              Content on this page requires a newer version of Adobe Flash Player.                      The Following Items Are Included: Fluke 199B 200MHz ScopeMeter Oscilloscope (BC# 20097)  1000V Hard Point Test Leads (1-Red, 1-Black) (2) 10:1 250MHz Voltage Probe Sets AC Adapter/Charger User Manual On CD-ROM Carrying Case (G)     BE SURE TO CHECK OUR EBAY STORE FOR OTHER ITEMS! This Item Has A Current Calibration!   Fluke 199B/003 ScopeMeter, 2.5GS/s Dual-Input 200MHz Oscilloscope   Includes Carrying Case & Accessories As Listed Above!     Working Condition: Excellent Condition: Refurbished Calibrated: Yes Warranty: 90 Day Exchange Warranty     ScopeMeter® 190 Series : All this power in your hand!  The ScopeMeter 190 Series has specifications you typically only find on high-end bench oscilloscopes. They offer up to 200 MHz bandwidth for capturing high frequency signals, as found in today’s state-of-the-art electronics, 2.5 GS/s real-time sampling and advanced memory and triggering functions. They’re rugged, compact and battery powered.   General Features: Dual-input - 200, 100 or 60 MHz bandwidth Up to 2.5 GS/s real-time sampling per input Choice between a high resolution Color display (190C Series) or Black & White display (190B Series) High waveform resolution of 3,000 datapoints per channel (NEW) Connect-and-View™ automatic triggering and a full range of manual trigger modes Frequency Spectrum Analysis using FFT (190C) (NEW) Digital Persistence for analyzing complex dynamic waveforms like on an analog scope Fast display update rate for seeing dynamic behavior instantaneously Automatic capture and replay of 100 screens 27,500 points per input record length using ScopeRecord™ mode TrendPlot™ paperless chart recorder for trend analysis up to 22 days Up to 1000 V independently floating isolated inputs Waveform reference for visual comparisons and automatic pass/fail testing of waveforms Vpwm function for motor drive and frequency inverter applications. 1000 V CAT II and 600 V CAT III safety certified Four hours rechargeable Ni-MH battery pack See what’s really happening High sampling rate gives you the required resolution for detailed signal analysis With a maximum real-time sampling rate of 2.5 GS/s per input, you can see what really happens, with 400 ps resolution. Both inputs have their own digitizer, so you can simultaneously acquire two waveforms and analyze them with the highest resolution and detail. If an anomaly flashes by on the screen, just press the Replay button to see it again. And thanks to the wider screen, you will always see a 12 divisions time-window – giving a far better overview of what’s happening both before and after the trigger event! Deeper waveform acquisition memory (NEW) Thanks to the deeper memory, very small parts of the waveform can be studied in full detail using ‘zoom’. The waveform memory of all oscilloscopes in both the 190B and 190C Series has been enlarged to allow as many as 3000 samples per channel to be acquired. This is 1800 samples more than before, giving much greater waveform resolution. You can use the ZOOM function to find tiny details in a long waveform, for example, the color burst in a video signal or a single impulse in a complex data-stream. All models also allow the high-resolution waveforms to be transferred to a PC for later detailed analysis using FlukeView ScopeMeter software. Easier identification of traces, everywhere Color traces and the high contrast display make signal identification easy The full-color display makes identification of individual waveforms easier, particularly when displaying large amplitude or multiple overlapping waveforms on screen. On-screen color labels, measurements and warnings are clearly linked to specific waveforms. The bright, high contrast display allows for clear reading under varying light conditions. And still a 4 hour battery operation time is assured! See dynamic signal behavior instantaneously Digital persistence mode gives analog scope like display of complex and modulated signals The Digital Persistence uses multiple intensity levels and user selectable decay time -it’s as if you’re looking at the display of an analog, real time oscilloscope! The fast display update rate that’s a standard on all models reveals signal changes instantaneously, useful for instance when making adjustments to a system under test. Advanced trigger modes Pulse width triggering allows you to find anomalies like missing pulses A wide choice of automatic and manual trigger modes gives you the flexibility to capture just about any signal you’ll encounter. Connect-and-View™ triggering is ideal for fast and easy checking of multiple test-points. The manual modes include time delay, video and pulse-width triggering. A fully isolated external trigger input is included for troubleshooting time relationships between two input signals synchronized to a third signal. (NEW) Dual-slope triggering used to capture the eyepattern on a digital datastream. Two new modes – ‘n-cycle triggering’ and ‘dual-slope triggering’ – have been added to the Fluke 190C Series to help you isolate the phenomena of interest. N-cycle triggering ensures you get a stable ‘live’ image of a signal, for example, in frequency dividers and clocked (synchronous) digital systems, or to synchronize on bursts of pulses. Dual-slope triggering enables the oscilloscopes to trigger on both rising and falling edges alike. This means that any edge in the signal will act as trigger event and initiate a new waveform acquisition, a most useful capability when making eye-patterns from digital data-streams, or in conjunction with single-shot phenomena. Automatic capture and replay of 100 screens Scope users know how frustrating it is to see a one-time anomaly flash by, never to be seen again. Not with the ScopeMeter 190 Series! Now you can look back in time with a touch of the replay button. In normal use, the instrument continuously memorizes the last 100 screens. Each time a new screen is acquired, the oldest is discarded. At any moment you can “freeze” the last 100 screens and scroll through picture-by-picture or replay as a ‘live’ animation. Cursors can be used for further analysis. Or you can use the advanced trigger capabilities to capture up to 100 specific events. Two sets of 100 captured screens with individual time stamps can be stored for later recall or download to a PC. Deep memory for high-resolution ScopeRecord™ Use the 27,500 points memory of the ScopeRecord mode and zoom in for maximum detail The ScopeRecord memory stores 27,500 points per input or more, for high resolution recording of events up to 48 hours, and captures fast intermit-tents and glitches as short as 50 ns. This continuous roll mode stores, for example, events like motion profiles, UPS-, power supply- and motor start-ups. All models also have a ‘Stop-on-Trigger’ in the ScopeRecord mode. This allows the ScopeMeter to store waveform data until the instrument is triggered or until a repetitive trigger signal is interrupted. This way, the instrument will, for example, automatically recognize a power failure and store the waveform data preceding it. And with 100 x zoom, you can look at the smallest details, like individual power cycles. Two of these 27,500 point recordings can be stored for later analysis. Measure from mV to kV – fully isolated and safely! Use Vpwm and measure effective voltage on motor drive and frequency inverter outputs The ScopeMeter 190 Series have three independently floating isolated inputs. While conventional oscilloscopes can only make measurements referenced to the line power ground, measurements on each of the Fluke ScopeMeter 190 Series inputs can be referenced to a different "low" level. This enables measurements in mixed circuits having different ground references, and also eliminates the risk of accidental ground short circuits. All inputs are safety certified for measurements in 1000 V CAT II and 600 V CAT III environments. And the standard probes cover a wide application range from mV to kV, making the ScopeMeter 190 Series ideal for micro-electronics to electrical power applications. Analysis power A wide variety of measurements can be made on either Channel A or B For analysis of waveforms, ScopeRecord and TrendPlot recordings, the ScopeMeter 190 Series feature 30 automatic measurements, plus cursors, zoom and a real-time clock. The analysis can be made directly or later when back in the office. Up to 2 recordings and 10 scope screens can be stored for analysis, print-out or download to a PC. Frequency Spectrum Analysis (NEW) Frequency Spectrum shows an overview of frequencies contained in a signal. All 190C Color ScopeMeters now include Frequency Spectrum Analysis functionality based on Fast Fourier Transformation (FFT) analysis as a standard feature. This makes it possible for you to identify the individual frequency components contained in a signal. The spectrum analysis function is also handy to reveal the effects of vibration, signal interference or crosstalk. An automatic window function assures optimal windowing, although you may manually select your preferred time window. Waveform Pass / Fail Testing Pass/Fail testing of actual signal against a reference template ‘Waveform reference’ allows an acquired trace to be stored and designated ‘reference trace’ for visual comparisons, or it can be used as the reference for automatic ‘Pass / Fail’ testing (190C). Up to 100 individually matching (‘Pass’) or non-matching (‘Fail’) waveforms can be stored in the replay memory, allowing you to monitor your system’s behavior over a long period of time, without the need for you to attend! Cursor-limited automatic measurement (NEW) The rms-value of the noise is measured on the part of the waveform enclosed by the cursors. Automatic power and Vrms-measurements can now be performed on a specific, user identified portion of the waveform using the cursors of the Fluke 190C to define the time-window of interest. In this way, the Color ScopeMeter can measure the power within a specified time span, or the rms-value of a voltage during a dedicated period of time. ... and there is more Variable gain on channel A helps you compare signals on the two inputs. All inputs are safety certified for measurements in 1000 V CAT II and 600 V The Vpwm measurement is for measuring the effective RMS output voltage of variable speed motor drives and frequency inverters. The high-sensitivity setting of 2 mV/div allows for measurements on low-level signals, that are hard to make with the average oscilloscope. Medical applications: For use on Medical Imaging Equipment and on High-Resolution Video systems, an optional instrument configuration is available for the Fluke 190 Series that supports measurement of Use TrendPlot™ to help find intermittents, fast Cursors and zoom help you analyze the captured TrendPlot The toughest faults to find are those that happen only once in a while: intermittents. They can be caused by bad connections, dust, dirt, corrosion or simply broken wiring or connectors. You may not be around to see it - your Fluke ScopeMeter will. In this "paperless recorder" mode, you can plot the minimum and maximum peak values and average over time - up to 22 days. The two inputs can plot any combination of voltage, current, temperature, frequency and phase - with time and date stamp -to help lead you to the cause of those faults quickly. FlukeView® Software for documenting, archiving and analysis FlukeView® for Windows® helps you get more out of your ScopeMeter by: Documenting - transfer waveforms, screens and measurement data from the ScopeMeter to a PC. Print or import the data into your report Add user text to individual ScopeMeter settings - providing guidance to the operator when recalling a set-up. Archiving - create a library of waveforms with your comments for easy reference and comparison. Store complete Replay cycles for analysis of waveform changes. Store complete memory content of the Scop Waveform Compare - store reference waveforms on the PC, or send a reference back to the ScopeMeter for waveform comparison and "Pass/Fail" testing. Analysis - use cursors, perform spectrum analysis or export data to other analysis programs. ScopeMeter test tools are connected to a PC via an optically-isolated RS-232 interface cable. Specifications Bandwidth: 200 MHz Real-time sample rate: 2.5 GS/s Inputs and digitizers: 2 plus external / DMM input   Independently floating isolated inputs: Up to 1000 V between inputs, references and ground  Timebase range: 5 ns - 2 min/div; 10 ns - 2 min/div (192B)  Input sensitivity: 5 mV-100 V/div  Glitch capture: 50 ns (5 µs/div - 1 min/div)  Scope measurements: Cursor: 7; Automatic: 30  Maximum record length: ScopeRecord mode: 27,500 pts per input; Scope mode: 3,000 pts per input  Memory: Screens: 10; Setups: 10  Display: 144 mm full monochrome LCD with fast update rate   Please check our Huge Inventory with savings of up to 80% off of retail on Cat5/5e/6 LAN Cable Certifiers and Fiber Optic OTDR's, Fusion Splicers, CATV Meters, Fiber Optic Kits, Sources, Meters, Tools, Network Analyzers and much more. Here is a Link to our Ebay Test Equipment Store. All of our Test Equipment is backed with a Full Warranty and unbeatable customer support & service. Please don't hesitate to contact us for a Quote on Something you don't see in our inventory, sometimes we have items that may have not been listed or processed yet.   Test Equipment Store Offers a wide range of Refurbished Telecom/ Datacom Tools and Test Measurement Equipment. Which includes Fiber Optic Test and Splicing tools, Fusion Splicers, OTDRs, Copper and Fiber Cable Certifiers, CATV Test Equipment, Cable and Antenna Analyzers, Network Analyzers and much more!   We carry a large inventory of quality refurbished and used test equipment from all the major manufacturers. If you are looking for multiple quantities or if we don't have a listing for a particular item that you are looking for. Please contact us as it may be fresh inventory waiting to be listed or we'll be glad to find it for you at the best price possible and put up an eBay listing for you!   Contact: Test Equipment Store eBay Sales Phone: 1-419-517-6681 Toll Free : 1-800-548-2381     We Ship World Wide!   We will attempt to ship your item(s) within 24 hours after payment has been received. To get a real-time shipping quote to your destination, enter your country and zip / postal code information into the shipping calculator and click "Get Rate". Many countries impose their own customs, duties, tariffs, taxes, etc. on items being shipped from a foreign country. We do not cover those cost's and we recommend that you contact your countries customs agency for that information. We Offer Multiple Quantity Price & Shipping Discounts, Email Us If You Are Interested In Larger Quantities.   UPS Ground   United States   USD 0.00 USPS Express Mail International (EMS)   Worldwide   USD 0.00   We accept credit card payment transactions via the online checkout system! The checkout process is designed so that it communicates with the merchant to confirm that payment has been made and cleared. Other methods of payment are outlined through the online checkout process. Winning bidders must contact us within 3 days after auction close if special payment arrangements are needed. Your payment is expected within 5 days after the auction close. Unpaid auctions will be forfeited after 5 days of the auction close and the Item(s) will be relisted for sale. Items will be shipped within 24 hours (1 Business Day) upon receipt of payment from the winning bidder. (Certain orders may take longer for processing due to comprehensive final service inspections) A Shipment Tracking number(s) will be provided to inform Buyers of their expected ETA (Estimated Time of Arrival). Tracking number(s) will be provided the same day as order shipment. Thank you ALL MAJOR CREDIT CARDS & PayPal ACCEPTED               Put your listings on autopilot with Kyozou eBay Listing Management Software
Condition:
Seller refurbished: An item that has been restored to working order by the eBay seller or a third party not approved by the manufacturer. This means the item has been inspected, cleaned, and repaired to full working order and is in excellent condition. This item may or may not be in original packaging. See the seller’s listing for full details. ...
Brand Fluke
Model 199B

Directions

Similar products from Cable Tester Kits

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies