Honeywell Aq2524m2 Universal Injection/mixing Boiler Reset Control Panel Nos

US $2100

  • Philadelphia, Pennsylvania, United States
  • May 25th
OFFERED: NEW OLD STOCK - NEVER USED OR INSTALED - ORIGINAL BOX AQ2524M2  -------  HONEYWELL Boiler and Mixing Control with DHW priority for 4 zones of pumps or valves AQ 2000 SERIES ADVANCED HYDRONIC     CONTROLS he AQ251 family of AQUATROL Boiler Reset Controls provides simplified, energy-efficient outdoor temperature compensated control of single temperature, residential hydronic heating systems. The AQ251 easily converts a single zone heating system into a room-by-room comfort control system, or upgrades a basic, relay-logic zoning system to intelligent Zone of Greatest Demand control with outdoor reset for in-creased energy efficiency with reduced boiler cycling. AQ251 boiler controls can ensure ample supply of hot water for both space heating and priority generation of domestic hot water for bathing, dishes and laundry. Features Use with AQ1000 2-wire polarity-insensitive communicating thermostats (AQ2514B2 and AQ2514B4) or dry contact thermostat (AQ2511B0) 0-10 Vdc modulating output for driving a modulating/condensing boiler. Displays outdoor temperature on all AQ1000 thermostats when used with an AQ12C10 outdoor sensor (included). Intuitive programming interface and armchair programming (can be programmed at your desk and taken to the job site "ready-to-install") Customizable control settings and schedules allow for greater level of control and comfort. Central programming of zone set points and setback. 1- or 2-stage zoning. Zoning Control for up to four zones as shipped; can be expanded to a total of 16 zones with AQ255 or AQ257 expansion zoning panels, and up to 64 zones by using AQ254 Add-a-Temperature expansion panels. Outdoor temperature compensation (reset), or Load reset based on indoor temperature feedback. Zone synchronization through Zone of Greatest Demand control. Domestic hot water priority and priority override protection. Line or low-voltage output for zoning equipment (pumps or valves). Boiler short cycling protection. Boiler post purge. Freeze protection. Pump/valve exercise. Boiler shock prevention from cold water returning to boiler. Automated test and purge feature for quick start-up and simplified troubleshooting. Integral 38 VA transformer with self resetting electronic fuse. 2 hour power supply (super-capacitor) to retain day and time settings during power outage. Non-volatile EPROM memory retains program settings during power outage. Specifications Description: Controls one boiler and one mixing (either variable speed injection or floating valve mixing) loop in a hydronic zoning system. Thermostat Compatibility: AQ1000 Series 2-wire communicating thermostats and most digital thermostats Setback Program: 7 day, up to 2 setback periods/day. User Interface (Setting, Programming): LCD Display and a 7 button Key Pad Number of Communicating Zones Controlled: 4 Boiler (Supply) Max. Control Temperature (F): OFF, 120F to 225 F Boiler Min. Control Temperature (F): OFF, 59F to 180F Outdoor Low Design Control Temperature (F): -60F to 32F Return Min. Control Temperature (F): 80 F to 180 F Boiler Differential: 2F to 41F (1C to 23C), or Auto (minimum 2 minutes on time) Boiler Heat Post Purge: Off, 10 seconds to 30 minutes (factory default is 30 seconds) Pump/Valve exercise: 30 seconds per 2 weeks of space heating inactivity Power Supply: 120V/60Hz R-C Output (on transformer): 38 VA, 24 Vac Class II R-C Input (on Control and Zoning Modules): 24 Vac Class II Supply/Return Sensor: Lead Length: 10 ft. (3050 mm). 10 kilohm NTC thermistor at 25 C (77 F) +/- 0.5F (+/-0.3C) up to 500 ft (150 M) using 18 AWG or larger wire, beta=3892. Heat Demand (Thermostat R-W) Input: External dry contacts connection only DHW Demand Input: External dry contacts connection only Boiler (T-T) Output Rating: 24 Vac, 0.5A, 12VA B-B Communication Bus Terminals: Low voltage, Class II, 2-wire polarity-insensitive, digital communicating link to other Control or Zoning modules. Zone Module Thermostat input: Low voltage, Class II, 2-wire polarity-insensitive, digital communicating with power link to AQ1000 series thermostat. Boiler Pump Output Rating: 120 Vac/250 Vac 5A, 1/3HP DHW Pump/Valve Output Rating 120 Vac/250 Vac 5A, 1/3HP Control and Zoning Panel Temperature Rating (F): 32 F to 130 F Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Dimensions (in.): 16 1/2 in wide x 8 in. high x 3 3/8 in deep Type of Zoning Devices Controlled: Zone pumps or 2-wire valves (line voltage) Boiler Design Temperature (F): 80F to 210F WWSD (Warm Weather Shut Down) Temperature (F): Off, 35 F to 100 F Number of Non-communicating Zone(s) Controlled:1 Electrical Connections (Line Voltage): Wire-clamp screw terminals, Maximum 2 x 14 AWG each on line voltage terminals Outdoor Sensor: Lead Length: 10 ft. (3050 mm). 10 kilohm NTC thermistor at 25 C (77 F) +/- 0.5F (+/-0.3C) up to 500 ft (150 M) using 18 AWG or larger wire, beta=3892 Shipping Cost | Easy Returns Powered by eBay Turbo Lister The free listing tool. List your items fast and easy and manage your active items.

Directions

Similar products from Other Heating, Ventilating & Air Conditioning Items

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies