Impact Uni-vent 750m Portable Ventilator (usaf/afmc Procurement Purchase)

US $394.00

  • Norman, Oklahoma, United States
  • Jan 30th
Fully Functional. Item Priced for Quick Sell - Great Portable Ventilator to have on hand. RECENT SURVEYS INCLUDING THE CITY OF NEW YORK STATE THAT MOST ALL EMERGENCY FACILITIES, MEDICAL CENTERS, HOSPITALS, ETC. ARE UNDER STOCKED AND WILL BE IN NEED OF MANY MORE PORTABLE VENTILATORS IF AND WHEN A FLU EPIDEMIC OCCURS. IT WAS ALSO STATED THAT THE LACK OR PORTABLE VENTILATORS IS CAUSE FOR CONCERN IN THE LIKELY HOOD OF THE NEXT NATURAL CATASTROPHE, WHEREAS, ANY MUNICIPALITY OR STATE DECLARES IT A STATE OF EMERGENCY. This Item was previously owned under a US Government Contract with Impact Instrumentation and Procurement. These Items have gone thru extensive testing by personnel of the Systems Research Branch, Crew Technology Division, Armstrong Laboratory, AFMC, while in use. Based on the Operational Manual & Service Guidelines provided Standard on all U.S. Department of Defense Procurements for the Uni-Vent 750 Portable Ventilator(s) which meets ISO-9001, and therefore is being SOLD AS-IS in GOOD WORKING CONDITION. Test methods and performance criteria were derived from various military standards, nationally recognized performance guidelines, and the Uni-Vent 750M portable ventilator operation and service manual.  Procedures covering safety and human factor issues have been developed by Aeromedical Research personnel. A test setup and a performance check were developed to verify proper functioning of the equipment under various conditions. See Photo for Condition of Item. It is as described and will be shipped in the exact same condition as in the photo's. The Winning Bidder will also receive Both Original Manuals on the Uni-Vent 750 Portable Ventilator (Normally Only available at additional cost to qualified commercial clients). Neither the Seller, nor any subsidiary, or agency thereof, nor any of their employees, nor any of their contractors, subcontractors, or their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its ready for patient use, for all inspections and patient readiness can be only certified by the end user and/or by its own qualified personnel. DETAILED INFORMATION ABOUT THE IMPACT 750M PORTABLE VENTILATOR: The Impact 750M (S/N 9105002), is a portable, electronically controlled, time-cycled, pressure-limited ventilator. It is controlled by an on-board microprocessor that continuously monitors the patient's airway pressure, all control settings, alarm parameters and power signals. The Impact 750M is operable from internal, rechargeable batteries: 11-30 volts AC or DC, positive or negative ground, 50 to 400 Hz. Its battery pack may be recharged within the range of either of the aforementioned AC or DC voltages. A 115/230 VAC, 50-400 Hz Multivoltage AC power supply and 12 VDC power cable are provided. The Impact 750M can deliver gas from a compressed gas cylinder, oxygen blender, electric compressor, PTLOX ( Portable Therapeutic Liquid Oxygen) or on-board aircraft generated oxygen source. Acceptable input gas pressures to the control module may range up to 100 psi, however, FLOW ADJUST control labeling is based on a 50 psi input. (See WARNINGS REGARDING USE in instruction manual.) The Impact 750M does not consume gas for operating power. It can provide ventilatory support in CONTROL, ASSIST-CONTROL and SYNCHRONIZED INTERMITTENT MANDATORY VENTILATION (SIMV) modes. Each mode is operable with or without sigh or PEEP (Positive End Expiratory Pressure). Multiple alarm systems are included. SPECIAL NOTES (NOT INCLUDED IN THE OPERATIONAL / SERVICE MANUAL) - Check the diaphragm valve located in the patient valve for proper placement prior to connecting patient to ventilator. Turn on the unit and cover the patient port to cause some resistance and look at the airway  pressure digital bar graph for positive pressure being delivered to the patient. - Heat sterilization may cause hazing of the patient valve. Carefully inspect prior to patient use to ensure all attachment ports will withstand use. - If a rapid decompression occurs, the FAL alarm could occur. Manual respiration must be assumed and the ventilator reset according to manufacturer's instructions. - For take-off and landings use for AeroMedical, it should be noted to use on battery power only. ***The following FDA Disclaimer is required for all eBay listing in Healthcare category and is Included for REFERENCE*** Sellers’s Contact Information: Iteleti ReMed | A Global Partner of HVOKC Cleaning Technologies, LLC | iteleti.com The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. Do not purchase this item unless you are an authorized purchaser. This item has been cleaned and handled in accordance with the manufacturer's instructions.  If the item is subject to FDA regulation, by purchasing, we will verify your status as an authorized purchaser of this item. If you have any questions refer to the FDA website which can be found at www.fda.gov   This Item is guaranteed to be as we represent herein. We do not offer or imply any guarantees or warranties on any equipment sold. It is the responsibility of the buyer to ensure that all equipment is functioning properly or refurbished before placing into patient use. Please note that we keep records on all serial numbers, as well as inspect and take photo's of each item before it's shipped. Also note that we do not refund packaging, nor the shipping and handling charges. Buyer must notify Seller of any discrepancies by email immediately upon receipt of the item to make arrangements. Upon APPROVAL FIRST, then upon receipt of returned item, Seller will inspect item to ensure it is in the same condition as originally shipped to buyer. If there are any missing parts or damages to the item, a refund will not be given. This Refund Policy guarantee applies to U.S. shipping addresses within the lower 48 states only. BY PROCEEDING WITH PURCHASE YOU ARE AGREEING TO THE TERMS OF OUR AUCTION AND ARE AWARE THERE IS NO RETURN POLICY. Should you have any questions or concerns please feel free to contact our Registered Office and ask any questions that you may have. You can reach our Registered Agent Toll-FREE at 866-918-4687. Thank You!
Condition:
Used: An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections. ...
Model Uni-Vent 750 Portable Ventilator
Country/Region of Manufacture United States
Brand Impact Instrumentation, Inc.
MPN 6530013270686

Directions

Similar products from Nebulizers & Ventilators

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies