Lcr-t5 Capacitance Diode Transistor Tester Resistance+inductance+esr +mos

US $30.80

  • Hongkong, Hong Kong
  • Jan 29th
i000000 LCR-T5 capacitance diode transistor tester resistance+inductance+ESR +MOS Click Photos to Enlarge Click to Enlarge Click to Enlarge Click to Enlarge Click to Enlarge Click to Enlarge Click to Enlarge Click to Enlarge Click to Enlarge Click to Enlarge Click to Enlarge Click to Enlarge       Description LCR-T5 capacitance diode transistor tester resistance+inductance+ESR +MOS  Add boot voltage detection function  * Automatic detection of NPN and PNP transistors, N-channel and P-channel MOSFET, diodes (including dual diode), thyristors, transistors, resistors and capacitors and other components,  * Automatic test out the pin element and displayed on the LCD  * Can be detected to determine the emitter forward bias voltage of the transistor Transistor, MOSFET protection diode and the amplification factor of the base  * Measure the gate threshold voltage and gate capacitance of the MOSFET  LCD monitors use 12864 * (128 * 64 characters)  * High test speed, valid component test: 2 seconds (except in the larger capacitor of large capacitance measurement also takes a long time, the measured time of one minute is normal)  * One button operation, power-on test, get a key.  * Power consumption off mode: less than 20 nA of  * Auto power off function to avoid unnecessary waste, saving battery power, improved battery life. 1. ATmega328 microcontroller.  2.1284 LCD display results.  3. One button operation, automatic power off.  4. Shutdown current is only 20nA, support battery operation.  5. ATmega328 in sleep mode when there is no measurement to reduce power consumption.  6. Automatic detection PNP and NPN bipolar transistor, N, P-channel MOSFET, JFET, diodes, dual diode, thyristor SCR.  7. Automatic detection pin layout.  8. Current amplification factor measurement of the bipolar transistor and the threshold voltage emitter junction.  9. Darlington transistor may be identified by the amplification factor of the high threshold voltage and high current.  10. For bipolar transistor, MOSFET protection diode testing.  11. Measuring the threshold voltage of the MOSFET and the gate capacitance.  12. Supports two resistance measurements and symbols show the highest four numbers and units. Both ends of the resistor symbol is shown connected to the tester probes number (1-3). Therefore, the potential can also be measured. If the potentiometer is adjusted to its end, the tester can not distinguish the two ends of the pin and the middle.  13. Resistance measurement resolution is 0.1 ohm, the highest measured value 50M ohms.  14. Can be detected and measured with a capacitor. Maximum four digits and units. Value can be from 25pf (8MHz clock, 50pF @ 1MHz clock) to 100mF. Resolution up to 1 pF (@ 8MHz clock).  15. For the above values can 2UF capacitor equivalent series resistance (ESR) capacitor value measurements. Resolution of 0.01 ohms and a two-digit numeric display.  16. Two diodes can display symbols in the right direction. Further, the display forward voltage drop.  17. LED detection diode forward voltage drop is much higher than normal. Dual LED detected as double diodes.  18. Zener diode can be detected if the reverse breakdown voltage is less than 4.5V. This is displayed as two diodes, can only be determined by the voltage. Diode symbol is the same around the probe, in this case you can 700mV threshold voltage near real identification diode anode!  19 If more than three diode-type parts detection, failure to establish the number of diodes another message. This will only happen if the diode is connected to all three probes and at least one diode. In this case, you should only connect the two measuring probe and start again, one by one.  20. Measuring a single diode reverse capacitance value. Bipolar transistors also can measure, if you connect the base and collector or emitter.  Twenty one. Only one measurement to find full-bridge connection.  Twenty two. Values less than 25pf capacitor typically undetectable, but a diode in parallel with 25pf capacitor or at least parallel. In this case, you must subtract the part of the parallel capacitance values.  Twenty three. Less than 2100 ohm resistor will measure inductance, if you have at least 16K ATMEGA flash. Range from 0:01 mH than 20H, but the accuracy is not good. Measurement results show only a single component connection.  Twenty four. Testing time is about two seconds, only capacitance and inductance measurements will take a long time.  25. Software can set the number of measurements before the power is automatically turned off.  26. Built-in self-test function with selectable clock frequency of 50Hz signal to check the accuracy and waits for a call (ATmega168 and ATmega328).  27. Optional internal resistance and zero offset calibration of measuring equipment self-test capability of the output port (ATmega168 and ATmega328). Need a 100nF to 20uF capacitor connected to the compensation between analog comparator pins 1 and 3 of the offset voltage. This can reduce the measurement error than 40uF capacitor. With the same internal calibration capacitor voltage internal reference voltage is found to adjust the reference measurement ADC gain.    If the test current exceeds the holding current, SCR and triac can be detected. But some current higher than the semiconductor SCR and triac tester can provide the trigger current. Available test current is only about 6mA! Notice: Before measuring capacitance , the capacitor must be discharged , otherwise very likely damage the meter . include:         1 PC  More information, you can send message to us.Thanks   O(∩_∩)O~~  Sweet Notice   If you have any problems with our items,pls contact with us .We can solve it for you perfectly. Pls trust us.Thanks. Feedback : We would appreciate receiving your 5 stars positive feedback.If there's any dissatisfaction with your parcel ,pls contact with us before you leave the feedback .We can solve it for your perfectly.Thanks for your understanding and help. Shipping time : If you haven't get your parcel within the expected date,Pls contact with us directly .We can ensure solve it for you . Pls trust us .We need your support. Thanks .Yours  Sincerely.   Country Shipping Time Refund or Resend 80% 12% 5% United States United Kingdom Australia /Canada  10-20 working days 25 working days 27 working days >27 working days Singapore  Other Asia country  15-25 working days 28 working days 32 working days >32 working days Germany /France Austria /Netherland  Poland 20-30 working days 33 working days 36 working days >36 working days Spain Russia  25-35 working days 37 working days 40 working days >40 working days Others 25-35 working days 37 working days 40 working days >40 working days     Return Policy :   1. All items are checked and packed in good condition before dispatch. 2. If you find any defect in our items, please contact us within 14 days of receipt item. 3. Return items must not be used. 4. Buyer is responsible for all return shipping charges. We will return all your money except the shipping and handling fees or make exchange for you after we receive your return items. Please do not ship the item back to us without our confirmation. Thanks       Payment and Shipping PAYMENT TERMS: We accept paypal .Credit card payments must be made through PayPal. SHIPPING TERMS: Our work time is during 8:00 am -5:30 pm ,from Monday to Friday (GMT+8 ).We will post your order within 24 hours (Except some special orders ,such as the handmade case). Maybe we are out of office during the weekend, so pls wait for our reply patiently. We will reply all your problems as quickly as we can. Thanks for your understanding.   inkfrog terapeak

Directions

Similar products from Inductance, Capacitance, Resistance and Impendace Meters & Analyzers

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies