Lot Of 3 Omron Contact Limit Switches Z-15gk355 Spdt With 40" Leads Multi-v

US $50.00

  • Topeka, Kansas, United States
  • Jun 9th
LOT OF 3 OMRON CONTACT LIMIT SWITCHES Z-15GK355 SPDT WITH 40" LEADS MULTI-VOLT, PRECISION ACTION BRAND NEW, NEVER USED, NEVER INSTALLED.FREE SHIPPING USING BUY IT NOW!! THANK YOU FOR LOOKING AND GOOD LUCK!! PLEASE TAKE A LOOK AT MY OTHER AUCTIONS!! Ratings Actuator Spring plunger (8.35 dia., Stainless steel plunger, high OP) Sensitivity Standard sensitivity Operation type General type Operating mechanism Snap action Switching mechanism Self-reset type Contact method Single-Pole, Double-Throw type Contact form SPDT Contact gap 0.5 mm Output Solder terminal Load General load Rated current 15 A Ratings (AC) Non-Inductive load Rated voltage: 125 VAC, Resistive load: 15 A (NC) 15 A (NO), Lamp load: 3 A (NC) 1.5 A (NO) Rated voltage: 250 VAC, Resistive load: 15 A (NC) 15 A (NO), Lamp load: 2.5 A (NC) 1.25 A (NO) Rated voltage: 500 VAC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 1.5 A (NC) 0.75 A (NO) Ratings (AC) Inductive load Rated voltage: 125 VAC, Inductive load: 15 A (NC) 15 A (NO), Motor load: 5 A (NC) 2.5 A (NO) Rated voltage: 250 VAC, Inductive load: 15 A (NC) 15 A (NO), Motor load: 3 A (NC) 1.5 A (NO) Rated voltage: 500 VAC, Inductive load: 6 A (NC) 6 A (NO), Motor load: 1.5 A (NC) 0.75 A (NO) Ratings (DC) Non-Inductive load Rated voltage: 8 VDC, Resistive load: 15 A (NC) 15 A (NO), Lamp load: 3 A (NC) 1.5 A (NO) Rated voltage: 14 VDC, Resistive load: 15 A (NC) 15 A (NO), Lamp load: 3 A (NC) 1.5 A (NO) Rated voltage: 30 VDC, Resistive load: 6 A (NC) 6 A (NO), Lamp load: 3 A (NC) 1.5 A (NO) Rated voltage: 125 VDC, Resistive load: 0.5 A (NC) 0.5 A (NO), Lamp load: 0.5 A (NC) 0.5 A (NO) Rated voltage: 250 VDC, Resistive load: 0.25 A (NC) 0.25 A (NO), Lamp load: 0.25 A (NC) 0.25 A (NO) Ratings (DC) Inductive load Rated voltage: 8 VDC, Inductive load: 15 A (NC) 15 A (NO), Motor load: 5 A (NC) 2.5 A (NO) Rated voltage: 14 VDC, Inductive load: 10 A (NC) 10 A (NO), Motor load: 5 A (NC) 2.5 A (NO) Rated voltage: 30 VDC, Inductive load: 5 A (NC) 5 A (NO), Motor load: 5 A (NC) 2.5 A (NO) Rated voltage: 125 VDC, Inductive load: 0.05 A (NC) 0.05 A (NO), Motor load: 0.05 A (NC) 0.05 A (NO) Rated voltage: 250 VDC, Inductive load: 0.03 A (NC) 0.03 A (NO), Motor load: 0.03 A (NC) 0.03 A (NO) Ratings explanation Lamp load has an inrush current of 10 times the steady-state current. Inductive load has a power factor of 0.4 Min. (AC) and a time constant of 7 ms Max. (DC). Motor load has an inrush current of 6 times the steady-state current. Inrush current NC: 30 A NO: 15 A Ambient temperature Operating: -15 to +80 CEL Storage: -15 to 80 CEL (with no icing or condensation) Ambient humidity Operating: 35 to 95% RH Storage: 35 to 95% RH (with no icing or condensation) Characteristics Speed of permissible operation 0.1 mm/s to 1000 mm/s Operating specification (Mechanically) 240 operations / 1 minute Max. Operating specification (Electrically) 20 operations / 1 minute Max. Contact resistance 15 mOhm Max. (Initial value) Measuring method is voltage drop method at 1 A, 6 to 8 VDC. Insulation resistance Between each terminal of the same polarities: 100 MOhm Min. Between live-metallic part and ground: 100 MOhm Min. Between each terminal and non-live-metallic part: 100 MOhm Min. (at 500 VDC Megger) Dielectric strength Between each terminal of the same polarities: 1,000 VAC Between live-metallic part and ground: 2,000 VAC Between each terminal and non-live-metallic part: 2,000 VAC (50/60 Hz for 1 min) Mechanical durability 10,000,000 operations Min. Electrical durability 500,000 operations Min. (rating load) Vibration resistance (Malfunction) Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Malfunction: 1 ms max. at the free position and the total travel position. Shock resistance (Destruction) 1,000 m/s**2 Shock resistance (Malfunction) Malfunction time is 1 ms Max. at the free position and the total travel position at 100 m/s**2. Degree of protection Drip-proof type IEC60529 (JEM): Equivalent to IP62 Applicable standard (UL) Standard No.: UL508 File No.: E41515 Applicable standard (CSA) Standard No.: CSA C22.2 No.55 File No.: LR21642 Applicable standard (TUV) Standard No.: EN61058-1 File No.: R9451585 Applicable standard (CCC (CQC)) Standard No.: GB14048.5 Applicable standard (EC Directive (Low Voltage Directive)) 2006/95/EC Mounting Method Mounting with screw Weight Approx. 36 g Operating characteristics Operating Force (OF) Standard value 5.3 N Max. Release Force (RF) Standard value 1.12 N Min. Pre-Travel (PT) Standard value 2.4 mm Max. Over-Travel (OT) Standard value 3.5 mm Min. Movement Differential (MD) Standard value 0.06 mm Max. Operating Position (OP) Standard value 37.8 +/- 1.2 mm (9/32" X 1")
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand OMRON
MPN Z-15GK355
Model SNAP ACTION
Country/Region of Manufacture Japan

Directions

Similar products from Automation Switches & Control Sensors

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies