New Icu Patient Monitor Ecg+nibp+spo2+pr+resp+temp Cms9200

US $1,250.00

  • Bohemia, New York, United States
  • Feb 24th
  NEW ICU Patient Monitor ECG+NIBP+Spo2+PR+Resp+Temp CMS9200                                       Contact person:STEVE         Email: MEDSERVICESINC@GMAIL.COM                                     The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 136606,                                          and certified by FDA of United States and CE,TUV of Europe. The  Fingertip Pulse Oximeter that is FDA 510K Approved WE HAVE THEM IS STOCK TO SHIP OUT TODAY,THANKS CMS9200 Patient Monitor Introduction:  CMS9200 features in high cost-performance, high safety and low power consumption. To ensure monitoring quality and reduce operation risk, it adopts full-isolation(floating), ECG defibrillation-proof protection, ECG anti-high frequency surgical unit and NIBP dual-overpressure protection. Features: ?Display mode: 15'' color TFT LCD with high-resolution. ?Be applicable for adult, pediatric and neonatal for all-round monitoring. ?Operation interface with Chinese and English. ?Waveform and data can be set optionally. ?Storage of 72-hour trend data, and review of 40-second holographic waveform. ?Full-lead ECG display. ?7-lead ECG displays in a screen, and ECG waveforms series display. ?Anti-high frequency surgical unit, defibrillation-proof(requirement for special leads). ?Adopt digital SpO2 technology, which has strong anti-interference and anti-weak filling capability. ?Function of NIBP review, storage for up to 400 NIBP data. ?Network: connecting with central station, other Bed observation and software updating. ?Network connection mode: wireless and wired. ?Built-in rechargeable battery for uninterrupted monitoring. ?Standard parameters of ECG, RESP, NIBP, SpO2, TEMP and PR. ?Built-in printer(optional). ?Standard parameters of ECG, RESP, NIBP, SpO2, and TEMP. ?IBP, CO2 and thermal printer are optional. Performance: ?ECG Lead Mode        3-lead and 5-lead are optional Lead Selection  I, II, III, avR, avL, avF, V Wave      5-lead: 2 channels                3-lead: 1channel Gain      x0.25, x0.5, x1, x2 HR Measuring and Alarm Range Range     15 ~ 300 bpm  Accuracy     ±1% or ±1bpm, which is greater Alarm Accuracy ±2bpm Resolution 1 bpm ?ST Segment Monitoring Measuring and Alarm Range -0.6 mV~ + 0.8 mV ?ARR ARR Detecting Type    ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Alarm Available Review Available Scan Speed for ECG Waveform   12.5mm/s, 25mm/s, 50mm/s ?Respiration (RESP) Method R-F(RA-LL) Impedance  Measuring and Alarm Range for Resp. Rate: Adult 0~120rpm Pediatric and Neonatal 0~150rpm Resolution   1 rpm Measuring Accuracy   2 rpm Apnea Alarm    10 ~ 40 S ?SpO2 Measuring and Alarm Range  0 ~ 100 % Resolution   1 % Accuracy:                  70% ~ 100% ±2%                  0% ~ 69% unspecified ?PR Measuring and Alarm Range  0~250bpm Resolution   1bpm Measuring Accuracy   ±2bpm or ±2%, which is greater Alarm Accuracy   ±2bpm ?NIBP Method    Oscillometry Mode    Manual, Auto, continuous  Measuring Interval in AUTO Mode 1 /2 /3 /4 /5/ 10/ 15/ 30 /60 /90 Min Measuring Period in Continuous Mode 5 Min Measuring and Alarm Range     10~270mmHg Resolution   1 mmHg Accuracy    ±10% or ±8mmHg, which is greater Over-pressure Protection:                      Adult Mode                     315±10 mmHg          Pediatric Mode   265±10 mmHg          Neonatal Mode   155±10 mmHg ?TEMP Channel    dual-channel Measuring and Alarm Range  0 ~ 50C Resolution   0.1C Accuracy    ±0.1C Optional  ?EtCO2 Method    Sidestream or Mainstream Measuring Range for CO2   0~150mmHg Resolution for CO2:                                                                     0.1 mm Hg  0 to 69 mm Hg                                0.25 mm Hg  70 to 150 mm Hg Accuracy for CO2: 0 – 40 mm Hg  ±2 mm Hg   41 – 70 mm Hg  ±5%   71 – 100 mm Hg  ±8%   101 – 150 mm Hg  ±10%   Respiration Rate>80BPM ±12% AwRR Range  2~150 rpm AwRR Accuracy  ±1BPM Apnea Alarm  Available ?IBP Channel   dual-channel Label   ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measuring and Alarm Range -50~350 mm Hg Resolution  1 mm Hg Accuracy   ±2% or 1mm Hg, which is greater ?Recorder   Print Mode thermal array  Recording Width 48mm  Paper Speed 25mm/s, 50mm/s  Quantity of Printing Waveform dual-channel ?Physical Characteristic: Dimension 365 x 150 x 340 (mm) Net Weight 4.0Kg Accessories: ?Adult SpO2 probe(5-pin) ?Adult NIBP cuff ?Extending tube for NIBP ?ECG lead ?ECG electrode ?Temperature probe ?IBP sensor(optional) ?IBP integration module(optional) ?IBP cable(optional) ?CO2 module(optional) ?CO2 collection pipe(optional) ?Power cord ?User Manual 
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Model cms9200
Brand Contec

Directions

Similar products from Other Medical Equipment

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies