      New Omron SHL-W155 Enclosed Limit Switch       Click to View Image Album Omron Enclosed Limit Switch SHL-W155 Hinge Lever , For Standard Load New no box Specs: Shape / Structure Enclosed Limit switches service life General type Operating mechanism Snap action Actuator Hinge lever Frequency 50/60 Hz Switching mechanism Self-reset mechanism Contact configuration Single-Pole, Double-Throw type Contact form SPDT Load General load Ratings (AC): Non-Inductive load Rated voltage: 125 VAC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 1.5 A (NC) 1.5 A (NO) Rated voltage: 250 VAC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 1.5 A (NC) 1.5 A (NO) Rated voltage: 480 VAC, Resistive load: 2 A (NC) 2 A (NO) Ratings (AC): Inductive load Rated voltage: 125 VAC, Inductive load: 3 A (NC) 3 A (NO), Motor load: 2.5 A (NC) 2.5 A (NO) Rated voltage: 250 VAC, Inductive load: 2 A (NC) 2 A (NO), Motor load: 1.5 A (NC) 1.5 A (NO) Ratings (DC): Non-Inductive load Rated voltage: 8 VDC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 2 A (NC) 2 A (NO) Rated voltage: 14 VDC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 2 A (NC) 2 A (NO) Rated voltage: 30 VDC, Resistive load: 5 A (NC) 5 A (NO), Lamp load: 1.5 A (NC) 1.5 A (NO) Rated voltage: 125 VDC, Resistive load: 0.4 A (NC) 0.4 A (NO), Lamp load: 0.4 A (NC) 0.4 A (NO) Rated voltage: 250 VDC, Resistive load: 0.2 A (NC) 0.2 A (NO), Lamp load: 0.2 A (NC) 0.2 A (NO) Ratings (DC): Inductive load Rated voltage: 8 VDC, Inductive load: 5 A (NC) 5 A (NO), Motor load: 2 A (NC) 2 A (NO) Rated voltage: 14 VDC, Inductive load: 5 A (NC) 5 A (NO), Motor load: 2 A (NC) 2 A (NO) Rated voltage: 30 VDC, Inductive load: 1.5 A (NC) 1.5 A (NO), Motor load: 1.5 A (NC) 1.5 A (NO) Rated voltage: 125 VDC, Inductive load: 0.05 A (NC) 0.05 A (NO), Motor load: 0.05 A (NC) 0.05 A (NO) Rated voltage: 250 VDC, Inductive load: 0.03 A (NC) 0.03 A (NO), Motor load: 0.03 A (NC) 0.03 A (NO) Explanation The above values indicate the steady-state current. Lamp load has an inrush current of 10 times the steady-state current. Inductive load has a power factor of 0.4 Min. (AC) and a time constant of 7 ms Max. (DC). Motor load has an inrush current of 6 times the steady-state current. Inrush current NC: 15 A NO: 15 A Protective circuit Classification of protection against electric shock: Class II (Double insulation) Short-circuit protective device: 10 A fuse type gI or gG (IEC269) Ambient temperature Operating: -10 to 80 CEL (with no icing or condensation) Ambient humidity Operating: 35 to 95%RH (with no icing or condensation) Characteristics Permissible operating speed 0.1 mm/s to 0.5 m/s Permissible operating frequency (Mechanically) 120 operations / 1 minute Max. Permissible operating frequency (Electrically) 30 operations / 1 minute Max. Contact resistance 15 mOhm Max. (Initial value) (Measuring method is contact resistance meter.) Insulation resistance Between each terminal of the same polarities: 100 MOhm Min. Between live-metallic part and ground: 100 MOhm Min. Between each terminal and non-live-metallic part: 100 MOhm Min. (at 500 VDC Megger) Dielectric strength Between each terminal of the same polarities: 1,000 VAC Between live-metallic part and ground: 2,000 VAC Between each terminal and non-live-metallic part: 2,000 VAC (50/60 Hz for 1 min) Durability (Mechanically) 10,000,000 operations Min. (No load) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) Durability (Electrically) 500,000 operations Min. (Resistive load 10 A at 125 VAC) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) Pollution degree 3 (EN60947-5-1) Vibration resistance (Malfunction) Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position. Shock resistance (Destruction) 1,000 m/s2 Shock resistance (Malfunction) Contact opening is 1 ms Max. at the free position and the total travel position at 300 m/s2. Degree of protection IEC60529 (JEM): IP67 NEMA250: Type1 Applicable standard (UL) Standard No.: UL508 File number: E76675 Applicable standard (CSA) Standard No.: C22.2 NO.14 File number: LR45746 Applicable standard (TUV) Standard No.: EN60947-5-1 File number: J50062486 Applicable standard (CCC(CQC)) Standard No.: GB14048.5 File number: 2003010305072162 Applicable standard (EC Directive (Low Voltage Directive) ) 2006/95/EC Mounting specification Side mounting Weight Approx. 66 g Operating characteristics Operating Force (OF) Standard value 2.35 N Max. Release Force (RF) Standard value 0.44 N Min. Pre-Travel (PT) Standard value 13 mm Max. Over-Travel (OT) Standard value 5 mm Min. Movement Differential (MD) Standard value 4 mm Max. Operating Position (OP) Standard value 21.5 +/- 1 mm Free Position (PF) Standard value 34.5 mm Max.   SHIPPING INFO: FLA RATE $7.00 USD Shipping Information on Large Items:You can get Instant Online Freight Quotes at the Freightquote Website It is free, quick,and easy to use. Please enter the Shipping Dimensions and Shipping Weight Listed Above.We are a Business with a Loading Docking Item Will be Shipped From Rockingham, NC 28379 Please contact Tom at 910-995-1336 with any questions, comments, or requests.Please ask questions as EARLY as possible, before the end of the item's auction. Payment Prompt Payment Is Expected !!       I accept the following forms of payment: PayPal Shipping & Handling Please See Auction Description to Determine Shipping Costs !! Thanks Again For Your Purchase !! We will e-mail you tracking information after the item ships. Please leave feedback for us on ebay after receiving your item. We will do the same for you.Sincerely,Tom910-995-1336 $7.00 USPS Priority Mail® Click to View Image Album Click to View Image Album Click to View Image Album Click to View Image Album   FREE scheduling, supersized images and templates. Get Vendio Sales Manager.     FREE scheduling, supersized images and templates. Get Vendio Sales Manager. Over 100,000,000 served. Get FREE counters from Vendio today! Click Here. Double your traffic. Get Vendio Gallery - Now FREE!
Condition:
New other (see details): A new, unused item with absolutely no signs of wear. The item may be missing the original packaging, or in the original packaging but not sealed. The item may be a factory second or a new, unused item with defects. See the seller’s listing for full details and description of any imperfections. ...
Model SHL-W155
Country of Manufacture Japan
MPN SHL-W155
Brand Omron

Directions

Similar products from Roller Lever Arm Swithces & Electrical Limit Switches

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies