New Square D Powerlogic High Density Power Meter Pm750 Hdmpm75048311 Pm700

US $350.00

  • Belcamp, Maryland, United States
  • Jun 9th
Brand new, first quality open box Schneider Electric Square D high density power meter & cabinet.   Square D PowerLogic model Power meter PM750 and case model HDMPM75048311. UNUSED, new, sealed in original factory box.  Came from electrical contractor liquidation.  Box was open for inspection.  Instructions, manuals and accessories inside (see photos). Check out my other listings for tons more liquidation electrical equipment, power supplies, industrial surge protection systems, parts, fire & life safety appliances, and other heavily discounted electrical items!  Best offer for bulk purchases.   Local pickup FREE welcome. Manufacturer info: PowerLogic® PM700 series  The PM700 series meter offers outstanding quality, versatility, and functionality in a cost-effective, ultra-compact unit. The meter is simple to use and offers a large, bright LCD display for superior readability even in extreme lighting conditions and viewing angles. An ideal replacement for analog meters, PM700 series meters can be used for stand-alone metering in custom panels, switchboards, switchgear, gensets, motor control centers, and UPS systems.  Complete with power, demand, energy, power factor, and frequency measurements, PM700 series meters are available in a variety of flexible configurations and have IEC62053-21 Class-1 and IEC62053-22 Class 0.5S (PM750 only) certification for basic sub-billing or cost allocation. The PM700 series meters are available in the following two versions: PM710: basic plus one RS 485 port (Modbus) PM750: basic plus an RS 485, two digital inputs, one digital output, and 15 user configurable alarms ? ?  Applications summary  Cost-effective metering  Easily mounted without tools (just two clips) and with a mounting depth of only 50mm, these cost effective and highly accurate power meters are ideal for OEMs and panel builders. The meters support direct connection up to 480 V AC Ph-Ph and seamlessly integrate with PowerLogic® energy management systems. Their high-accuracy power, energy, and demand measurements can be used for bill verification, monitoring backup power for critical systems, and cost effective energy management solutions.  Remote monitoring and control  Get early warning of impending problems that could lead to equipment malfunctions or downtime. Diagnose and isolate the cause of powerrelated equipment or process problems. The PM750 features 15 userconfigurable alarms for the most prevelant over and under conditions common in most power systems. Combine any of the PM750’s I/Os with these alarms and communicate through its 2-wire RS-485 port for remote monitoring and control capabilities for greater control over the performance and overall health of your systems. Perfect for demand control applications.  Sub-billing and cost allocation  Perfect for monitoring right down to the tool level, the PM700 series meters can help monitor cost centers, identify opportunities for demand control, and check energy consumption patterns.  Features summary  Cost-effective  Simple retrofit  Low initial investment  Ease of use  Fast setup via display or software  Compatible with entry-level PowerView™ software  Bright, easy to read LCD display  High accuracy metering PM710: Real Energy IEC 62053-21 ANSI C12.16. 1.0 Accuracy Class PM750 - Real Energy IEC 62053-22 ANSI C12.20. 0.5 Accuracy Class  Communications  RS-485 port (PM710, PM750) Modbus® protocol for integration with energy management systems  Energy management systems Modbus compatible, ready to use with PowerLogic® PowerView™ and System Manager Software, Tenant Metering Software (TMS) and PowerLogic® ION® Enterprise Software  Pulse outputs 1 output (PM750) for kWh-pulsing, alarm status, or external controlled output  Pulse inputs 2 inputs (PM750) for status, alarms or demand input synchronization  Patented technology An architecture that uniquely addresses monitoring and control applications Adapts to changing needs, avoiding obsolescence Measurements  Metering  Real time true RMS electrical parameters up to the 15th harmonic 32 samples per cycle  Measurement accuracy per internationally recognized standards  Energy and demand measurements  Per phase voltage, current, peak current demand, watts, VARs, kWh, and more  Neutral current, THD, frequency, power factor, and more  Meter unit  Physical configuration  Ideal for low voltage switchboards, shallow cable compartments, standalone machines, and a wide range of commercial and industrial applications  Mount on switchboard doors to maximize free space for electrical devices  No tools required; mount meter with clips  Front panel display  Bright LCD back lit display with easy to read digits: Intuitive display operation and context-based menus  Easy setup for common configuration parameters  Password protection on setup parameters  Password protection for demand reset  Pulse outputs (PM750) kWh with PM750  Pulse input (PM750) Trigger alarms or monitor I/O status applications via two digital inputs  Notifications and alarms (PM750) Control processes, avoid penalties and perform proactive maintenance using alarms  Communications RS-485 port with standard Modbus RTU Baud rates from 9,600 bps to 19,200 bps Flexible power supplies 100 to 415 ±10 % V AC, 5 VA 125 to 250 ±20 % V DC, 3 W ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?  Specifications  Accuracy Current: PM710 - 0.5% from 1A to 6A PM750 - 0.4% from 1A to 6A  Voltage: PM710 - 0.5% (50V to 277V) PM750 - 0.3% (50V to 277V)  Power Factor: 0.5% from 1A to 6A Power: PM710 - 1% PM750 - 0.5% Frequency: ±0.02 % from 45 to 65 Hz Real Energy: PM710 Class 1 as defined by IEC 62053-21 ANSI C12.16. 1.0 Accuracy Class PM750 Class 0.5S as defined by IEC 62053-22 ANSI C12.20. 0.5 Accuracy Class Reactive Energy: Class 2 as defined by IEC 62053-23 Environmental conditions Operating temp: -5° C to 60° C (41° F to 140° F) (meter) -10° C to 50° C (50°F to 122°F) (display) Storage temp (meter and display): -40° C to 85° C (104° F to 185° F) Humidity rating: 5% to 95% RH at 50° C (122° F) (non-condensing) Altitude: 3000m (9843 ft.) maximum Input-voltage characteristics Measured voltage: 10 to 480 V AC (direct Ph-Ph) 10 to 277 V AC (direct Ph-N) up to 1.6 MV AC (with external VT), start of measuring voltage depends on PT ratio Metering over-range: 1.2 Un Impedance: 2 M ? (Ph-Ph) / 1 M ? (Ph-N) Frequency range: 45 to 65 Hz Input-current characteristics CT ratings: Primary: adjustable from 5 A to 32767 A Secondary: 5 A or 1 A Measurement input range: 5 mA to 6 A Permissible overload: 10 A continuous 50 A for 10 seconds per hour 120 A for 1 second per hour Impedance: < 0.1 ? Load: < 0.15 VA Mechanical characteristics Dimensions: 96 x 96 x 69 mm (3.78” x 2.72”) (meter with display) 96 x 96 x 50 mm (3.78” x 2.72”) (behind mounting surface) Weight: 0.37 kg (0.8 lb)
Condition:
New other (see details): A new, unused item with absolutely no signs of wear. The item may be missing the original packaging, or in the original packaging but not sealed. The item may be a factory second or a new, unused item with defects. See the seller’s listing for full details and description of any imperfections. ...
Brand Square D
MPN HDMPM75048311
Model PowerLogic

Directions

Similar products from Plug Energy Meters and Power Meters

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies