Notifier By Honeywell Udact Universal Digital Alarm Communicator Transmitter

US $450

  • Ste-Julienne, QC, Canada
  • Jun 6th
NOTIFIER by Honeywell UDACT Universal Digital Alarm Communicator Transmitter VERY GOOD CONDITION Item that has been used previously Clean and intact but may have some signs of cosmetic wear I cannot test item but it comes with a full refund no Defective on arrival (DOA) warranty DESCRIPTION : The NOTIFIER Universal Digital Alarm Communicator Transmitter (UDACT) is designed for use on the Notifier NFS-320, NFS2- 640, NFS2-3030, NFS-640 and NFS-3030 Fire Alarm Control Panels and on the NCA-2 and NCA Network Control Annunciator. When used in conjunction with the NCA-2 network control annunciators the NOTIFIER UDACT can report the status of all control panels on NOTI•FIRE•NET. The UDACT transmits system status to UL listed Central Station Receivers via the public switched telephone network. The NOTIFIER UDACT is compact in size and may be mounted externally in a separate cabinet. The UDACT is capable of transmitting the status of software zones (Alarm and Trouble), System Trouble, Panel Off-Normal, Supervisory, Bell Trouble, Low Battery, and AC Fail. The UDACT is capable of transmitting all of the zone and point status associated with each panel. When the NOTIFIER UDACT is used with the NFS-3030, NFS2-3030, and NCA-2, it is capable of reporting up to 2,040 points. Reporting may be in the form of points or zones. The first 568 points transmitted may be programmed for a variety of types, including fire, waterflow, supervisory, etc. Remaining points transmitted are for fire alarm only. FEATURES : Maximum of 14 point trouble messages transmitted per hour. Dual phone lines. Dual telephone line voltage detect. Surface Mount Technology. Compact in size: 6.75" x 4.25" (17.145 x 10.795 cm). Built-in programmer. Built-in 4-character red 7-segment LED display. Manual Test Report function. Manual Transmission Clear function. Mounts in a separate enclosure (ABS-8RB or UBS-1). Communicates vital system status including: Independent zone fire alarm. Independent zone non-fire alarm. Independent zone trouble. Independent zone supervisory. AC (mains) Power Loss (programmable). Low Battery and Earth Fault. System Off-Normal. 12 or 24 hour test signal. Abnormal Test Signal per new UL requirements. EIA-485 Communication Bus Failure. Annunciation of UDACT Troubles including: loss of phonelines, communication failure with either Central Station, total communications failure. Troubleshoot Mode converts keypad to DTMF touchpad. Open Collector relay driver for Total Communications Failure or UDACT trouble. Real-time clock. Extensive transient protection. Simple EIA-485 interface to host panel. AGENCY LISTINGS AND APPROVALS : UL Listed: S635 ULC Listed: CS100 Vol. VII MEA: 328-94-E; 317-01-E3 CSFM: 7300-0028:174; 7165-0028:214; 7165-0028:224; 7170-0228:216; 7170-0028:223; 7165-0028:243, 7170- 0028:244 INDUSTRY CANADA: 2132 6030 A FCC: 1W6-USA-20723-AL-E FM Approved INCLUDES : 2 Connectors (See photos) **International Customers** Buyers are responsible for any customs duties, taxes, tariffs or brokerage fees associated with shipping to their respective countries. PLEASE, WATCH CAREFULLY PUBLISHED PHOTOS FOR PRODUCT DESCRIPTION, YOU GET EXACT ITEM THAT YOU SEE. I only ship to PayPal verified address Returns are accepted within 14 days of an order delivery. All returns must have a Return Authorization(RA)

Directions

Similar products from Fire Alarming Systems

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies