Perkin Elmer Geneamp 9600 Pcr System

US $236.20

  • Orlando, Florida, United States
  • Jan 30th
*Price Reduced! Motivated Seller!* This Perkin Elmer GeneAmp PCR 9600 is in great shape and passes all self tests, except the cooling self test, where it does not come down to low temperature fast enough to pass the test. It comes down to low temperature eventually, just a few seconds too slow to pass the self test. Consequently, it's sold for parts. If you repair it, you'll get a dramatic discount. The GeneAmp® PCR System 9600 is an auto­mated instrument, specifically designed for control­ling the times and temperatures required by the GeneAmp Polymerase Chain Reaction (PCR) process for nucleic acid amplification. The GeneAmp PCR System 9600 consists of a 96-well position aluminum sample block, which is heated by a film heater and cooled by an internal refrigeration unit. User interface is through a full numeric keypad with heating and cooling indicator lights and information viewed an a 2x20 character fluorescent display. An optional printer can be attached through the RS232C interface and hard copy of the programmed protocols and achieved times/temperatures can be obtained.   GENEAMP PCR SYSTEM 9600 FEATURES Samples and temperatures Sample Capacity: Up to 96, 0.2-mL MicroAmp® PCR Reaction Tubes Internal Memory: 150 user files Modifiable Programs. Modifiable HOLD program for maintaining a specific temperature for either an indefinite or fixed time period. Modifiable CYCL program contains the pattern of thermal ramp and hold segments for PCR cycling. Contains up to nine setpoints, each of which comprises a ramp segment and a hold segment for the specific target temperature. The pattern can be repeated up to 99 times. AUTO program allows the user to automatically increment or decrement the setpoint times and temperatures by a fixed amount every cycle. User Diagnostics. Ability to run a number of diagnostic routines to verify heating and cooling rates, overshoot and undershoot temperatures, and check display functions.  Temperature Range: 4.0-99.9°C Temperature Display: Calculated sample tem­peratures displayed and setable to 0.1°C Heating/Cooling Rates: Average heating and cooling rate of 1 °C/second for the sample Static Sample Temperature Uniformity: ± 0.5°C, 30 seconds after clock start, over the range 35-100°C Temperature Accuracy: ± 0.75°C over the range 35-100°C Temperature Calibration: The GeneAmp PCR System 9600 is calibrated to standards traceable to the NIST (National Institute for Standards and Technology, U.S.).   Software Internal Memory. 150 user files Modifiable Programs. Modifiable HOLD program for maintaining a specific temperature for either an indefinite or fixed time period. Modifiable CYCL program contains the pattern of thermal ramp and hold segments for PCR cycling. Contains up to nine setpoints, each of which com-prises a ramp segment and a hold segment for the specific target temperature. The pattern can be repeated up to 99 times. AUTO program allows the user to automatically increment or decrement the setpoint times and temperatures by a fixed amount every cycle. User Diagnostics. Ability to run a number of diagnostic routines to verify heating and cooling rates, overshoot and undershoot temperatures, and check display functions.   PCR Performance Guarantee Using the GeneAmp PCR System 9600 and the GeneAmp® PCR Reagent Kit, an amplification yield of at least 100,000 fold of the Lambda Control DNA target can be achieved with: 0.2 µM each of the Lambda Control Primers 0.1 ng of Lambda Control DNA target 50-µL reaction volume without a mineral oil overlay in a 0.2-mL MicroAmp® Reaction Tube 25 thermal cycles: 94°C for 15 seconds, 68°C for 60 seconds. Dimensions Width: 52 cm (20 in.) Depth: 61 cm (24 in.) Height: 30.5 cm (12 in.) Weight: 40.5 kg (90 lb)   Power Part Number   Voltage            Frequency N801-0001      120 VAC         60 Hz
Condition For parts or not working :
An item that does not function as intended and is not fully operational. This includes items that are defective in ways that render them difficult to use, items that require service or repair, or items missing essential components. See the seller’s listing for full details.
Seller Notes All functions work properly except cooling does not proceed at fast enough pace to pass self-test. Probably means that the cooling coils need to be cleaned. Passes all heating self-tests. Sold As-Is.

Directions

Similar products from Other Heating & Chilling Equipment

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies