Professional Q Switch Yag Laser Tattoo Pigment Eyebrow Removal Machine 1000mj

US $3700

  • ShenZhen,Guangdong, China
  • Jan 30th
About Us | Contact Us | Payment Info | Shipping Info | Return Policy STORE HOME NEW ARRIVALS FEATURED PRODUCTS HOT SHOPPING ON SALE leading China beauty & health equipment supplier Breast Enhancer | Weight Loss | Skin Rejuvenation | Hair Removal | Massage | Detox | Acne Remover | Lightening | Health care | Testing HOME > PRO Q SWITCH YAG LASER MACHINE TATTOO EYEBROW REMOVAL Tattoo/Eyebrow/Lipline/Freckle/Birthmark Removal PRO Q SWITCH YAG LASER MACHINE TATTOO EYEBROW REMOVAL UPDATED Professional Q Switch YAG Laser Machine Model:          HR-LS450 Shipping:     Shipping to Worldwide. In Stock:     Usually leaves our warehouse same business day.                                  Click Image To Enlarge International Buyers Please Note: a. Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility. b. Please check with your country's customs office to determine what these additional costs will be prior to bidding/buying. Introduction: ND: YAG Laser Cosmetic System introduces gem-adjusting Q switch, which uses high energy by instant emission of laser beam to crush and remove the pigment effectively in the pathologically changed tissues. That is an explosion led by laser beam: the laser beam at the fixed wavelength enabled by the accumulated high energy can reach the pathologically changed tissues through epidermis in a very short time (only 6 ns) to instantly crush the respective color base, then the corresponding pigment group gets swollen and outburst at last due to high energy, and part of the pigment group springs out of the human body (at shallow epidermis), and the rest (at basis tissues) pigment group will become very small particle before swallowed by the human cell which will be finally discharged out of the human body through lymphatic system circulation. The pigment of the pathological tissues will fade in color till it vanishes. And the surrounding normal tissues will not be ruined since they will not absorb the laser at that fixed wavelength . Application: The system gem-adjusting Q switch can effectively cure the mixed pigments by pigment precipitation of extraneous source with pathological pigment change of endogenous source, inclusive of erroneous dark eyebrow-embroidery, lip-embroidery, lip-soak, eye line-embroidery, lip-line, tattoo (inclusive of tattoo by extraneous wounds), pigment precipitation by sensitive source, freckle on female's face (male's), coffee spot, old age spot, black mole, and birthmark in black, blue, purple, brown, red and etc. Treatment course for different illness case as follows: Treatments Treatment course required ( cure times) Treatment course interval Remark (requirements in surgery) eyebrow-embroidery(eyeliner grain) 1 –2 times 30-60 days Eyebrow blow, eyeball protection Eyebrow-embroidery ( eyeliner embroidery) 1-3 times 45-60 days Eyebrow blow, eyeball protection Lip line (red dyed lip) 1-3 times 15-45 days Use 532nm filter Tattoo(caused by extraneous wounds) 1-4 times 30-60 days Blood infiltration will be fine on wounds Freckle, age spot 1-4 times 15-30 days Blood infiltration will be fine on wounds Birthmark, nevus/mole 3-7 times 45-90 days Must have Blood infiltration . (1)Treatment for tattoo in eyebrow Customer could not open eyes during treatment, operator should adjust energy according to depth of tattoo color, hold the handle and move it to treatment area slowly to make customer feel acceptable in mentally. Right now, the speed of flash could be set 3HZ, keep head of the handle a two-finger distance to treatment area, start treatment from head of eyebrow to end of eyebrow. It is needed to treat again in 5-10 minutes if the color of tattoo re-appear. (2)Remove eye line The speed of flashes could be set 4-5HZ,adjust the energy of light to minimum energy, keep a one-finger distance between head of handle and treatment area. Operator should strictly protect customers’ eyes with panel for eyelid or medical pledget (panel for eyelid)of 1cm depth. Treatment should be started from down eye line, customer should deeply close eyes and keep eyeball up-sight inside. Operator should press the pledget (panel for eyelid) with forefinger and push up eyelid, peel down eyelid with middle finger to bare the eye line, treat it with flashes of 4-5Hz. Then, treat up eye line. Also customer should close eyes and keep eyeball down-sight inside. Operator should press the pledget (panel for eyelid) with middle finger and push eyelid down, push eyelid up with forefinger to bare the eye line, treat it with flashes of 4-5Hz. (3)Remove lip line The speed of flashes could be set 5Hz,keep a 3/4 finger distance between head of handle and treatment area. It is better to remove black, coffee, deep, red and brown lip line with 1064nm head at first time and then, treat again with 532 nm head. Notice: All tattoos in lip should be treated in 6 months after making. OR removal treatment will fail. It should have 45-60 days interval to continue next treatment until remove all. (4)Remove tattoo The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for treatment until treatment area seeps a little blood. It should have 45-90 days interval to continue next treatment until remove all. (5)Remove spot and nevus The speed of flashes could be set 3Hz/5Hz.Keep 3-4 fingers distance between head of handle and treatment area. It is better to use high energy for treatment until treatment area seeps a little blood. It is advised to use 1064 nm head for normal spot and nevus treatment, but for deep color spot and nevus, it is better to use 532nm head for treatment. It should have a 15-30days interval to continue next treatment until remove all. (6)Remove birthmark The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for treatment until treatment area seeps a little blood. It is advised to use 1064nm head for birthmark treatment, but for red and deep color birthmark, it is better to use 532nm head for treatment. It should have 45-90 days interval to continue Technical Parameters: Cooling condition: wind system+closed circulating+cooling system Laser type: Q-switch Nd: YAG Laser output wave length: 1064nm/532nm The pulse energy: 0~1000mJ Pulse width: 6ns Recurrence rate: 1, 2, 3, 4, 5Hz Power source: 110v~220v Packing included: 1 x Main Unit 1x Handpiece 1 x 532nm tip (mainly used for red, coffee and brown pigment treatment) 1 x 1064nm tip (mainly used for blue, black and cyan pigment treatment) 1 x Water funnel 1 x Package box 1 x Foot touch 1 x Protective goggle 1 x Power line (we stock 110V-240V power version and US.UK.UA.EU plugs for the country all of the world) Features: 1.Innovative in laser technology,strict in technical detection,precise in manufacture,stable and effective in performance. 2.Special designed cooling system ensures constantly working. 3.Micro Computer counts the shoots. 4.Portable and aseismatic,convenient for transportation. 5.user friendly interface with LCD display 6.No injury to normal tissue. 7.Remove pigmentation without side effects or scar. 8.Short Treatment period with outstanding effect.
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Model HR-LS450
Country of Manufacture China

Directions

Similar products from Other Medical Devices & Machines

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies