Search Radiation Detector Dosimeters Mks-11 Geiger Counter

US $9,999.00

  • UA, Ukraine
  • Jan 29th
                                         An  with a full warranty service. Sold only NEW dosimeter    SPECTRA   (Search dosimeter-radiometer MKS-11) your radiation safety! English Version What is radiation? Radiation is a form of emission that changes the state of nuclei and atoms, transforming them into electrically charged ions and products of nuclear reaction. Different forms of radiation have different penetration ability, therefore they unequally affect our organism.         Alpha radiation is a stream of positively charged particles (nuclei of helium atoms), which move at the speed of about 20 000 km/sec. Alpha radiation is absorbed by a sheet of paper and it hardly penetrates the human's skin. But it is dangerous when particles get into the body through food, air or wounds. The range of alpha particles in the air is 11 cm, and in soft tissues - a few microns.         Beta radiation is a stream of negatively charged particles (electrons) with the speed close to the speed of light. Beta radiation can penetrate the human's skin at the depth of 1-2 centimeters, but everyday clothes are already an enough protection. Beta particles have different energy so their range in the air is not the same varying from a few meters to a centimeter.         Gamma radiation is a short-wave electromagnetic emission. Its properties are rather similar to those of X-rays, but it has far higher speed and energy, spreading with the speed of light. Gamma radiation has great penetration ability but can be weakened by walls of buildings and metal constructions. My other lots - here click Useful advices Purpose of use:     The MKS-11 “Spectra” search dosimeter-radiometer is designed to measure ambient dose equivalent rate of gamma and X-ray radiation (hereinafter called photon-ionizing radiation DER), to determine neutron radiation intensity, as well as to identify gamma radionuclides. The device provides accumulation, saving in the non-volatile memory and identification of amplitude gamma spectra.   The device is used to detect and localize radioactive and nuclear materials relative to their gamma and neutron radiation with the aim to prevent illicit transfer of these materials. It is also used at enterprises and organizations dealing with gamma and neutron radiation sources.     Specifications                                                                                                                                                                                                                                                                                                                  - Gamma radiation sensitivity for 137Cs, not less than (pulse/s)/(µSv/h) 100±15 - Neutron radiation sensitivity for:            - fast neutrons, not less than            - thermal neutrons, not less than pulse*centimeter? / neutron           0.120±0.012           1.2±0.12 - Measurement range of photon-ionizing radiation DER µSv/h 0,05 - 9999 - Indication range of photon-ionizing radiation count rate pulse/s 1 - 9999 - Indication range of neutron radiation count rate pulse/s 0,01 - 9999,00 - Main relative permissible error limit of photon-ionizing radiation DER measurement (137Cs) % ±(15+1/H*(10)), where H*(10) - is a measured value of DER, equivalent to µSv/h - Energy range of detected photon-ionizing radiation MeV 0,033 - 3,000 - Energy dependence of the device readings at photon-ionizing radiation DER measurement in the energy range from 0.05 to 1.25 MeV relative to 0.662 MeV energy (137Cs) % ±25 - Energy range of detected neutron radiation MeV from thermal neutrons to 14.00 - Number of channels of amplitude gamma spectrum channel 1024 - Time of operating mode setting of the device, not more than min 1 - Calibration time relative to gamma background s 2 - 60 - Time of continuous operation when powered from charged storage batteries under normal gamma background (not more than 0.5 ?Sv/h), with switched off display backlight and no alarm, not less than h 30 - Operating temperature range °? - 20 ... + 50 - Dimensions of the detecting device (DD), not more than mm 110x36x83 - Weight of the DD, not more than kg 0,4 - Dimensions of the control and indication device (CID) without strap, not more than mm 70x80x32 - Weight of the CID, not more than kg 0.13 - Weight of the device kit in packing case, not more than kg 1,5                                                                                                                                                       My other lots - here click Highlights: Features:   High sensitivity gamma scintillation (CsJ) detector, Geiger-Muller counter, scintillation (LiJ) detector of neutron radiation.   Mode of indication and automatic testing of batteries residual capacity.   Data communication between the detecting device (DD), the control and indication device (CID) and the PC is done via Bluetooth wireless technology.   Option to save and transfer to personal computer 128 full gamma radiation spectra.   Identification of radionuclides with indication of the category that they belong to (in compliance with IAEA requirements):   medical radionuclides: 18F, 67Ga, 99mTc, 111In, 123I, 131I, 201Tl;   industrial radionuclides: 57Co, 60Co, 133Ba, 137Cs, 192Ir, 152Eu and 241Am;   special nuclear materials: 233U, 235U, Pu [reactor-grade plutonium (more than 6%240Pu)];   naturally occurring radioactive materials: 40K, 226Ra, 232Th and daughters, 238U and daughters. Note: The list of nuclides that can be detected by the device can be enlarged if needed.   Threshold alarm system with three independent threshold levels:               search threshold level (threshold level of pulse count rate from the detector of photon-ionizing radiation);         safety threshold level (threshold level of photon-ionizing radiation DER);         threshold level of pulse count rate from the detector of neutron radiation.         In the Box:   Control and indication device   Detecting device   NiMH storage battery of AA size   NiMH storage batteries of AAA size (2 pcs.)   Battery charger   Leather case   Screwdriver   Operating manual   Packing   My other lots - here click Easy payment method which is very safe and secure. When using PayPal your item is covered by the Paypal Payment Protection programme up to the value of $2000.   FREE SHIPPING* on each ADDITIONAL item you purchase Issued Tracking Number. You're protected against theft, loss of your purchase. Ship EMS - 80 usd - delivery 7-14 working days Ship Fedex - 190 usd - delivery 3-8 working days Should you have any questions - ask We ship worlwide to Confirmed Address only We can mark new items as gift, commercial sample or return goods, or we can decrease cost of items. But in this case, buyer loses insurance. Note we are not responsible for the duties or taxes your country may impose nor can we predict what those fees are The buyer is responsible for any applicable import duty and local taxes. Please verify with your customs before purchase. 30 days money back guaranteed by Western Bid Inc: Warranty All our products have manufacture warranty, manufacturer of products, Claims for guarantee repairs are not accepted at: operation rules violatin mechanical damages All the questions concerned returning and exchanging the product, are solved in accordance with the Consumer protection laws. Warning! The guarantee does not cover batteries. In case of return for warranty service please kindly contact us for the return instructions We are an electronic, phone free organization (with real people to answer emails). Please  use contact seller feature in ebay for any Questions? Comments! or Requests we will do our best to reply the same day or the next BUSINESS day. (M-F 9AM-6PM EST) If you have already purchased, please include your ebay name We reply to all e-mails, if you did not get a reply try to contact us directly thru e-bay and make sure your e-mail spam setting allows our e-mails in.     ©merkurydnepr               
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand Ecotest
Type Dosimeters
Model Spectra
Country of Manufacture Ukraine

Directions

Similar products from Radiation Dose Meters & Detectors

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies