Siglent 10mhz Sdg810 Signal Function Arbitrary Waveform Generator 125msa/s

US $6200

  • Canton, China
  • Jan 29th
Overview SDG800 Series Function/Arbitrary Waveform Generator is equipped with maximum output frequency of 5 MHZ, 10 MHZ, 30 MHZ, and 125 MSa/s sampling rate. With the new innovated EasyPulse technology, SDG800 can generate pulse of low jitter, quick rising/falling edge regardless of frequency effect, while the duty cycle, edge and pulse width could be widely and accurately adjusted. SDG800 is much superior in performance to similar DDS signal generator. DHL/UPS  Advanced DDS technology,125MSa/s sampling rate, 14bit vertical resolution Single channel output, 5 kinds of standard waveforms, built-in 46 kinds of arbitrary waveforms (including DC) Complete modulation functions: AM, DSB-AM,FM, PM, FSK, ASK, PWM, linear/logarithmic sweep  and burst Innovative EasyPulse technology, can output pulse of low jitter, quick rising/falling edge Standard interfaces: USB Device, USB Host, support U-Disk storage and software update Provide 10 nonvolatile storage spaces for user’s arbitrary waveforms Be capable of seamlessly connected to SIGLENT Digital Storage Oscilloscope Configurable with powerful arbitrary waveform editing software EasyWave Model SDG805 SDG810 SDG830 Maximum output frequency 5MHz 10MHz 30MHz Output channels 1 Sampling rate 125 MSa/s Wave length 16 kpts Frequency resolution 1 ?Hz Vertical resolution 14 bits Waveform Sine?Square?Ramp?Pulse?Gaussian white noise?Arbitrary waveform,46 types of built-in arbitrary waveforms Sine wave 1?Hz ~ 5MHz 1?Hz ~ 10MHz 1?Hz ~30MHz Square wave 1?Hz ~ 5MHz 1?Hz ~ 10MHz 1?Hz ~10MHz Pulse 500?Hz ~ 5MHz 500?Hz ~ 5MHz 500?Hz ~5MHz Ramp/Triangular 1?Hz ~ 300KHz 1?Hz ~ 300KHz 1?Hz ~ 300KHz Gaussian white noise >5MHz bandwidth(-3dB) >10MHz bandwidth(-3dB) >30MHz bandwidth(-3dB) Arbitrary waveform 1?Hz ~ 5MHz 1?Hz ~ 5MHz 1?Hz ~ 5MHz Modulation function AM?FM?PM?DSB-AM?FSK?ASK?PWM?Sweep?Burst Standard configuration USB Host & USB Device Amplitude (High resistence) 4mVpp~20Vpp(HighZ), 2mVpp~10Vpp(50ohm) Detailed performance parameters and technical guidance please refer to<SDG800 Series DataSheet> Standard Accessories A power cord that fits the standard of destination country A USB cable A QuickStart Guide A Warranty Card An EasyWave arbitrary waveform editing software A BNC to double alligator clip wire Optional Accessories BNC cable USB-GPIB Adapter ——————————————————————————————————————————————————————  Figure 1  Comparison of edge under 1KHz pulse signal As shown in figure 1, under 1KHz frequency, EasyPulse can keep quick rising/falling edge (20ns) while the edge of ordinary DDS is very slow. Figure 2  Comparison of edge adjusting range under 1KHz pulse signal As shown in figure 2, EasyPulse edge adjustment has a wide range, while ordinary DDS pulse edge adjustment is limited. Figure 3  Built-in 46 kinds of arbitrary waveforms (including DC) As shown in figure 3, SDG800 Series can output 5 kinds of standard waveforms and 46 kinds of commonly used waveforms, including common waveforms, mathematical functions, application functions, window functions and trigonometric functions.  Figure 4  Multiple modulation function As shown in figure 4, SDG800 Series support multiple modulation function: AM, DSB - AM, FM, PM, FSK, ASK, PWM, linear/logarithmic sweep and burst. Figure 5  Support PC editing software EasyWave As shown in figure 5, SDG800 Series support powerful PC editing software EasyWave, which can output arbitrary waveform featured 14bit vertical resolution and 16Kpts wave length. EasyWave provides 9 standard waveforms: Sine, Square, Ramp, Pulse, ExRise, ExpFall, Sinc, Noise and DC, which meet all engineers’ basic needs. In addition, it provides a variety of draw modes like manual drawing, straightline drawing(including horizontal straightline, vertical straightline, point-to-point straightline), coordinate drawing and equation drawing, making it easy to create complex waveforms. Multiple Document Interface management makes simultaneous multiple-waveform editing. SDG800 Series provides 10 nonvolatile storage spaces for arbitrary waveforms, and you can also edit and store more waveforms through EasyWave software. 1,The oscilloscope cannot start? First, check the power cord and power strip, check the power switch to make sure it is open (SDS1000CFL series has a power switch and a power protection switch). To judge whether the machine is powered on through checking fan’s working status, if the fan works, the machine is powered on. If everything is normal but the oscilloscope still cannot start, please contact the after sale service. 2,The screen does not appear waveform during the signal acquisition? 1)    Check the connection of the probes and signals. 2)    Check the connection of the signal cable and BNC. 3)    Check the connection of the probes and objects. 4)    Check whether the object generates signals 5)    Repeat the acquisition 6)    Check the trigger status 3,Waveform is appeared but not stable 1)    Check the trigger source channel panel is consistent with the actual signal path. 2)    Manually adjust the LEVEL trigger knob to see whether the waveform is stable. 3)    Use AUTO to adjust the waveform automatically to see whether the waveform is stable 4)    Adjust time base, rule out false-wave interference 4,Amplitude is not exactly 1)    Check the unit of source amplitude, the default unit is Vpp of aumo measurement which means difference between the highest and lowest value, the effective value. For example, commercial power we say is 220Vrms but the Vpp is over 600V       2)    Oscilloscope is not an accurate measurement tool, according to chip digit the vertical axis will have quantization error.     5,Distortion is big when check high frenquency signal  1)    Distortion is bigger when measuring signal near toplimit of oscilloscope bandwidth. Usually bandwidth should be greater than or equal to five times bandwidth of measuring signal, at that time the distortion will be very small.     2)    Wrong probe will lead to distored waveform. At first bandwidth of probe should be greater than signal bandwidth, it would be best if it is greater than or euqal five times. And then, if probe is divided into 1X and 10X, 1X is usually 6MHz-10MHz, 10X is the maximum bandwidth of probe.        6,Waveform is interfered when measuring small signal 1)    Siglent SDS1000 series can measure mV signal. It will turn on bandwidth limitation function at 2mV/div and filter high frequency clutter.           2)    Contact clip to reference earth of signal which can reduce the distortion because of electric difference between oscilloscope and measuring signal.  Shipping Payment Return Feedback Communication 1.Item will be shipped within 1-2 working days after full payment is cleared. Tracking number will be sent to all customers upon package shipment.   2.Delivery time is different in accordance to shipping address and shipping methods. -Economy shipping from China: about 20-30 biz days. -ePacket delivery (EUB) from China to US: about 10-15 biz days. -Expedited shipping from China takes about 3-5 biz days via DHL/UPS and 9-15 biz days via EMS. -Standard shipping (Royal Mail Tracked) from UK warehouse to local customers: about 3-5 biz days. -Standard shipping from US warehouse: about 3-7 biz days. -Expedited shipping from US warehouse: about 3-5 biz days. 3.Delivery time depends on destination,logistics mode and other factors. If you have not received your shipment within 30 days from payment, please feel free to contact us. We will track the shipment and get back to you as soon as possible with a reply. Customer`s satisfaction is our goal. 1. We accept payment via PAYPAL ONLY which provides full-scale buyer protection policy up to $500. We only ship to confirmed PAYPAL addresses.Please makesure payment address in PayPal is correct. 2. All major credit cards are accepted through our secure payment processor PayPal. 3. Payment must be received within 7 business days of auction closing. 1.60 days money back return policy. If you are not satisfied when you?receive your item, please return it within 60 days for a replacement or money back. Please contact us for return address before you send it back. 2. If item defective, in 3 months we will send you a replacement without extra charge, or offer refund upon faulty received. after 3 months you are still welcomed to send it back to us for exchange. Buyer may responsible for all return shipping costs. 3.In case you receive wrong products due to shipping error, please contact us for exchange or refund. If it's damaged , please refuse to accept and contact us as soon as possible. Please email us before leaving any negative feedback or open any dispute on PayPal. We care about our valued customers, and will always try to help you. So if you have any problems, please e-mail us immediately. We try our best to reply to your emails as soon as possible. If you do not receive any reply from us, please check your email ensuring your mailbox has not reached full size. You can contact us by Ebay messages.
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand Siglent
Sampling rate 125 MSa/s
Model SDG810
Wave length 16 kpts
Channel 1

Directions

Similar products from Other Signal Generating Equipment

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies