Sigma 8002 Iv Pump, Baxter Tubing, Sigma 8000, Iv Pump, Iv Fluids

US $100.00

  • Charlotte, North Carolina, United States
  • Jan 30th
USED SIGMA 8002  IV INFUSION PUMP WITH 5 NEW BAXTER IV SETS.  ALL UNITS HAVE BEEN TESTED USING BAXTER TUBING AND THE VOLUME DELIVERY IS ACCURATE. ALL UNITS HAVE BEEN TESTED USING AC POWER ONLY.   PICTURE IS OF A REPRESENTATIVE EXAMPLE OF AVAILABLE UNITS. PLEASE FEEL FREE TO ASK ANY QUESTIONS. UNITS GUARANTEED NOT TO BE  DOA AND AS DESCRIBED,   GOOD LUCK. Overall Size/Weight: 10 lbs., 9.5" x 6.5"W x 6.75"D (416.81 cubic inches) Flow Range: 0.1-999 mL/hr (0.1 mL increments from 0.1-99.9 mL/hr & 1.0 mL increments above) Flow Rate Accuracy: +/-5% nominal for rates 2-999 and +/- 10% from 0.1-1.9 mL/hr over 72 hours Volume Limit: 0.1-9,999 mL volume limit range Total Volume Delivered: 0.1-9,999 mL cumulative counter KVO Rate: 1 mL/hr or selected rate which ever is lower Rated Voltage: 105/135 VAC (0.5A), 50/60 Hz, fused T500Ma (IEC 127) 220/240 VAC (0.25A), 50/60 Hz, fused T250Ma (IEC 127) Ground Resistance: <0.13 ohm Patient Leakage: < 15 micro amps, normal condition; <50 micro amp, single fault condition Battery: 12-volt battery pack consisting of 6 each 2V/2.5 amp hr rechargeable sealed lead acid batteries Electromagnetic: Electromagnetic compatibility immunity and emissions are in compliance with IEC 601-1-2 and IEC 601-2-24 Disposables: Standard Gravity IV sets by Abbott, Baxter or B. Braun-McGaw* Pumping Mechanism: Linear Peristaltic Air Sensor: Ultrasonic Communications: RS 232 Port Memory: Lithium back-up battery History Log: Last 360 events Alarms: Air-In-Line, Upstream & Downstream Occlusion, Improper IV Set Loading, Infusion Complete, Low Battery, Plug In, Pump Malfunction, Close Roller clamp, Empty Container (with optional flow sensor) Listing & Certifications: NRTL/C, to CSA Standard C22.2 LUD Medical Distributors, 234 East Webb street, Charlotte, NC 25984, 1-800-434-8543   The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item."  

Directions

Similar products from Feeding & Infusion Pumps

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies