*tested* National Instruments Ni Pci-6281, 18-bit Hi-accuracy M-series Daq

US $540

  • Boise, Idaho, United States
  • Jan 29th
This listing is for a fully tested PCI-6281, M-Series, High-Accuracy (18-bit analog inputs) Multifunction DAQ board for PCI, with 16 analog inputs (18-bit, 16 single-ended, or 8 differential), 2 analog outputs (16-bit), 24 bits digital I/O, and dual 32-bit counters/timers. Assy  #191342A-03. The board passes NI Diagnostics 2.1 testing, NI-MAX self-tests and self-calibration. The testing included full range and bandwidth of all 16 inputs in all modes, including differential, RSE (ground referenced), and NRSE (non-ground referenced), analog outputs checked for static accuracy and full range dynamic performance, all digital inputs and outputs checked for proper logic levels/switching thresholds. from NI- The NI PCI-6281 is a high-accuracy multifunction M Series data acquisition (DAQ) board optimized for 18-bit analog input accuracy. This resolution is equivalent to 5 1/2 digits for DC measurements. To ensure accuracy, the NI-PGIA 2 amplifier technology is optimized for high linearity and fast settling to 18 bits, and programmable lowpass filters reject high-frequency noise and prevent aliasing. 16 Analog Inputs, 18-Bit, 500 kS/s (Multichannel), 625 kS/s (1-Channel); Two 16-bit analog outputs (2.8 MS/s); 24 digital I/O; Two 32-bit, 80 MHz counters; Programmable 40 kHz lowpass filters NI-MCal calibration technology for increased measurement accuracy; Correlated DIO (8 clocked lines, 10 MHz); Analog and digital triggering. The PCI-6281 will be well packaged and sent in box via USPS Priority Mail, signature required, fully insured. the tracking # will be entered into ebay and paypal after shipment.
Condition Used :
An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections.
Seller Notes Used National Instruments PCI-6281 board for PCI, fully tested and in working condition. Has minor cosmetic wear that will not affect function or performance.

Directions

Similar products from Data Loggers and Data Acquisition Cards

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies