Thermotron S-16c Environmental Temperature Test Chamber 16 Cu. Ft. 30"x 30"x 30"

US $8,999.99

  • Phoenix, Arizona, United States
  • Jan 30th
Click Here. Double your traffic. Get Vendio Gallery - Now FREE! Thermotron S-16C Environmental Temperature Test Chamber Comes with what you see in the pictures. If you don't see it, you probably wont get it. Specifications are from Thermotron and may vary slightly due to upgrades, options, or revisions this unit may or may not have. The chamber is guaranteed to be in working condition. The Unit's Serial Number Tag Reads: Model Number: S-16C Serial Number: 19496-S Electrical Requirements: 208V, 3-Phase, 48.6 A, 60 Hz Date of Manufacture: 6-27-90 Refrigeration: R-13, R-502 Options: Air Dryer / Purge System Key Features: 16 Cubic Feet Work Capacity Maximum Temperature Range from -100°F to +350°F (-73.3°C to +177°C) Air-cooled, mechanical refrigeration system with hermetically sealed compressors Immediate operation with suitable power connection High volume air circulation fan Stainless steel access port Cabinet: The entire chamber is built of high quality steel. No wood, fiberboard, plastic or similar materials are used in the construction. The interior is constructed of 304 Series, high-nickel content stainless steel with 2B finish. The liner is heliarc welded for hermetic sealing to prevent moisture migration to insulation space. The exterior shell is constructed of die-formed, 16" gauge galveneal. Gaskets are extruded, designed to be used with seamless corners. Two separate gaskets are installed to insure minimum heat loss from the chamber -- a silicone inner gasket and a vinyl outer gasket. The circulator motor is located outside the chamber. It has a solid stainless steel shaft; no extensions are used. Ball bearings are lubricated for life and located out of the conditioned area. A hinged instrument panel makes service and calibration easier. Electrical System: The chamber has a solid-state, photo-isolated, zero-voltage switching, heat-power relay. Chamber has a fusible link heater cut off at +460°F (+288°C). All motor electrical components, switches, and fuses are located in a self-contained panel. All components are fused. Chamber wiring is contained in "panel channel" and is accessible with completely unlacing or unthreading any wires. All wires are identified. Identification provided on pilot lights and switches for all major circuits. Wiring meets NEC and NEMA standards. Refrigeration System: Refrigeration system has all silphosed or silver soldered joints - no soft solder is used. The system is air cooled and capable of starting under various ambient conditions. The condensers are manufactured to meet our exacting standards. Cooling coils are heavy-duty copper tubing with specially designed aluminum fins. The system is sealed and balanced to achieve the ultimate in performance and reliability. Specifications: Workspace: 113 liters Volume: 16 cubic feet Voltage, ±10%: 115 Volts / 1 Phase / 60 Hertz Recommended Minimum Service Amps at 230 Volts: 50 A, single phase or 40 A, three phase Temperature Range: -73.3°C to +177°C (-100°F to +350°F) Approximate Weight: 1320 lbs. (599 kg.) - does not include packaging Chamber Heater Wattage: 3.5 kW Compressor Size: (2) 2 H.P. Cascade System Circulator Motor: (2) 1/15 HP, 3000 RPM Workspace Dimensions: 30" Wide x 30" Deep x 30" High (76cm Wide x 76cm Deep x 76cm High) Overall Chamber Move-In Dimensions: 43" Wide x 35.75" Deep x 75" High (109cm Wide x 142cm Deep x 191cm High) Window: 20" x 20" (51 cm x 51 cm) Access Port Diameter: 4" right-side, center of workspace Note 1: Performance is based on 60 Hz operation and +75°F (+23°C) ambient air. Performance*: Temperature Pull Down from a Stabilized Control Conditioned of +75°F (+23°C) without Load: to -40°F (-40°C): 15 Min. to -65°F (-53.9°C): 30 Min. to -100°F (-73.3°C): 60 Min. Temperature Heat Up from +75°F Ambient without Load:: to +240°F (+116°C): 25 Min. to +350°F (+177°C): 55 Min. Capacity for Holding Live Loads at Temperatures Below +100°F only (dissipation in watts): at 0°F (-17.8°C): 1000 Watts at -40°F (-40°C): 700 Watts at -65°F (-53.9°C): 400 Watts Control: Air temperature control as measured at the controller thermocouple ±2°F. Sensitivity ±1/4°F. *: Performance based on 60 Hz operation and +80°F ambient air. For 50 Hz operation, refrigeration and air flow performance will be approximately 17% less. (.8333). Performance may also be based on a newer model controller, model 2800 which this chamber does not have installed. For More Pictures Please Click the Following: Picture 2 - Back View Picture 3 - Right Side View Picture 4 - Left Side View Picture 5 - Chamber Door Open Picture 6 - Temperature Controller Picture 7 - Temperature Limit Controller (Therm-Alarm) Picture 8 - Air Dryer/Purger System Picture 9 - R-13 Refrigerant Gauges Picture 10 - R-502 Refrigerant Gauges Picture 11 - Serial Number Tag $250.00 minimum for packaging, handling, and order processing. Shipping to be determined by destination. If you have any questions please call Michael at 1-866-MHZ-ELEC (1-866-649-3532) Toll Free. Also, please click here to view or other auctions! 04/25/14 Powered by eBay Turbo Lister The free listing tool. List your items fast and easy and manage your active items.
Condition Used :
An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections.
Seller Notes The chamber is guaranteed to be in working condition.

Directions

Similar products from Environmental & Testing Chambers

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies