Topcon Kr-8000 Autorefractor/keratometer

US $4,895.00

  • Littleton, Colorado, United States
  • Jan 30th
Topcon KR-8000 Pre-Owned Refurbished This unit has undergone a complete and rigorous internal & external refurbishment process and has been tested to operate at factory specifications. Accessories Included: 90-Day Limited Warranty Policy This instrument qualifies for our 90-Day warranty policy against fault workmanship and manufacturing defects.  The World’s Smallest Pupil Dilation: 2.0mm The innovative design of the KR-8000 enables accurate, reliable refraction and keratometric measurements within a pupil dilation as narrow as 2.0mm. This means easier and more precise diagnostic results when dealing with glaucoma, asymmetric pupils or elderly patients.        Auto-Alignment, Auto-Start The 3D auto-alignment system offers easy operation and speedy measurement in which a precise focus is automatically obtained without any skill. The KR-8000 offers Auto-Start function. As soon as the instrument is properly aligned, this innovative function initiates the measurement process and completes three readings of each eye. When the readings are complete, a printout of measurement results is automatically generated. Corneal Diameter Measurement Corneal diameter can be measured either during testing of the patient or later by recalling an image of the cornea on the monitor. Measurements can be obtained for both eyes, with the data recorded on the printouts if required.     Scenic Fixation Chart This scenic color chart is adjustable in two brightness level for optimal results with large or small pupils, making eye fixation easier.   Omni-Directional Joystick Fast, positive and responsive control of operations is performed with our omni-directional joystick that leaves the user one hand free to operate other functions. Even novice operators can obtain excellent results. Also for the KR-8000PA SUPRA, the vertical movement is electric and corresponds to the rotation of the joystick.   Improved Functionality Auto Shut-Down To conserve enegy and prevent any built-up of heat from electronic circuitry, the instrument incorporates an automated function to shut down the instrument when left unused for more than 10 minutes. Automatic PD Measurement For binocular readings, PD measurement is performed automatically; the value obtained is stored in the patient’s data file and printed out together with the results of objective tests.  
Condition Seller refurbished :
An item that has been restored to working order by the eBay seller or a third party not approved by the manufacturer. This means the item has been inspected, cleaned, and repaired to full working order and is in excellent condition. This item may or may not be in original packaging. See the seller’s listing for full details.
Seller Notes This unit has undergone a complete and rigorous internal & external refurbishment process and has been tested to operate at factory specifications.

Directions

Similar products from Keratometers & Autorefractors

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies