Tripp-lite Pdunv Power Distribution Unit 16a 120-240v 

US $99.99

  • Des Plaines, Illinois, United States
  • Aug 30th
1.9-3.8kWSingle-Phase 120-240V Basic PDU, 14 Outlets (12 C13 & 2 C19), C20 with 5Adapters, 10 ft. (3.05 m) Cord, 1U Rack-Mount MODEL NUMBER: PDUNV     Versatile 16A 120-240V PDU compatible with wide range ofvoltages to deliver single-phase AC power to multiple loads from a utilityoutlet, generator or UPS system. Recommended for data centers, server rooms andnetwork closets.   Highlights  C20 input with10-ft. (3.05 m) cord and 5 adapters  14 total outlets—12C13 and 2 C19  Switchless design prevents accidental shutdown   Reversible all-metal housing  16A circuit breaker protects against overloads   Package Includes  PDUNV 1.6/3.8kWSingle- Phase 120-240V Basic PDU   (5) C19 plug adapters   Mounting brackets   Owner’s manual     Description The PDUNV 1.6/3.8kW Single-Phase 120-240V Basic PDU is aversatile no-frills unit for data centers, server rooms and network wiringclosets. Perfectly suited for high-density IT environments, the PDUNV features14 total outlets—four C13 in front and eight C13 and two C19 in the rear.   The C20 input plug with 10-ft. (3.05 m) cord connects tyour facility's compatible AC power source, generator or protected UPS todistribute power to connected equipment. Five C19 plug adapters with lockingretainer clips are included for connection in a variety of power environments.The adapters convert the plug to C14 (connects to C13 120-240V), NEMA L6-20P(L6-20R 20A 208/240V), NEMA L5-20P (L5- 20R 20A 120V), NEMA 5-20P (5-20R 20A120V) or NEMA 5-15P (5-15R 15A 120V).   The switchless design prevents an accidental shutdown,which could lead to costly downtime. A 16A circuit breaker protects connectedequipment from dangerous overloads. The reversible all-metal housing supports avariety of mounting options, including 1U horizontal or 0U vertical mounting inEIA-standard 19-inch racks, under a counter or on a wall or workbench withuser-supplied hardware. It also supports toolless 0U vertical mounting with theoptional PDUSIDEBRKT (sold separately).   Features Reliable Single-Phase 16A 120-240V PowerDistribution   Versatileno-frills PDU for data centers, server rooms and network wiring closets   14 totaloutlets—4 C13 in front, 8 C13 and 2 C19 in rear   C20 input with10-ft. (3.05 m) cord and 5 plug adapters     Rear-panelgrounding lug   16A circuitbreaker protects against overloads     C19 Plug Adapters Included   For connectingto AC power in various power environments   Lockingretainer clips included   Adapters: C14,NEMA L6-20P, NEMA L5-20P, NEMA 5-20P and NEMA 5-15P     Switchless Design   Preventsaccidental shutdowns and costly downtime     Versatile Installation Options   Reversibleall-metal housing faces front or rear in rack   Supports 1Uhorizontal or 0U vertical mounting in EIA-standard 19 in. racks   Also mounts onwall, workbench or under a counter   Supportstoolless 0U vertical mounting with optional PDUSIDEBRKT (sold separately)   Specifications     OVERVIEW UPC Code 037332127204 PDU Type Basic   INPUT PDU Input Voltage 120-240V Recommended Electrical Service Single-phase 16/20A 120-240V service Maximum Input Amps 16 PDU Plug Type NEMA 5-15P; NEMA 5-20P; NEMA L5-20P; NEMA L6-20P; IEC-320 C14; IEC-320 C20 Input Phase Single-Phase Input Cord Length (ft.) 10 Input Cord Length (m) 3.05   OUTPUT Output Capacity Details 3.84kW (240V), 3.68kW (230V), 3.52kW (220V), 3.33kW (208V), 3.2kW (200V), 2.03kW (127V), 1.92kW (120V) / 16A total capacity; 16A max per C19 outlet; 12A (10A CE) max per C13 outlet Frequency Compatibility 50 / 60 Hz Output Receptacles (12) C13; (2) C19 Output Nominal Voltage 120-240V Overload Protection 16A circuit breaker     PHYSICAL Material of Construction Metal Form Factors Supported 1U rackmount, 0U vertical mount, wallmount and under-counter mounting supported Minimum Required Rack Depth (cm) 19.81 Minimum Required Rack Depth (inches)   7.8 Outlets Measurement (Center to Center) Distance between Front (C13) outlets = 28.75mm; Distance between Rear (C19) outlets = 55mm; Distance between Rear (C13) outelts = 28.75mm PDU Form Factor Horizontal (1U) Shipping Dimensions (hwd / cm) 6.10 x 27.94 x 51.31 Shipping Dimensions (hwd / in.) 2.40 x 11.00 x 20.20 Shipping Weight (kg) 3.18 Shipping Weight (lbs.) 7.00 Unit Dimensions (hwd / cm) 4,44 x 44,45 x 10,8 Unit Dimensions (hwd / in.) 1.75 x 17.5 x 4.25 Unit Weight (kg) 1.45 Unit Weight (lbs.) 3.20   ENVIRONMENTAL Operating Temperature Range 0C ~ 40C (32F ~ 104F) Storage Temperature Range -30°C to +50°C (-22°F to +122°F) Relative Humidity 5 to 95% non condensing Operating Elevation (ft.) 0-10,000 Operating Elevation (m) 0-3000   STANDARDS & COMPLIANCE Certifications Tested to UL60950-1 (USA), CSA (Canada), CE (EU)
Condition:
New – Open box: An item in excellent, new condition with no functional defects. The item may be missing original packaging and may have been used for testing or demo purposes. The item includes accessories found with the original product and may include a warranty. See the seller's listing for full details and description. ...
Brand Tripp Lite
Output Voltage Rating (DC) 16 V
Nominal Voltage Rating (AC) 240 V
Model PDUNV
Nominal Current Rating 240 A
Inrush Current Rating 16 A
Product Type Power Distribution Unit
MPN AGIB24016RMPDU
UPC Does not apply

Directions

Similar products from Voltage Converters & Meters

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies