TSI 4040 Mass Flowmeter for Gases with LCD Features: Characteristics: TSI 4040 Mass Flowmeter for Gases with LCD   Flow response is 4 milliseconds   ±2% of reading accuracy   Turn-down ratio exceeds 1000:1   Pressure drop is ultra-low   Output of flow rate can be analog or digital   Output of other digital readings include volume, pressure, and temperature   Temperature and pressure compensation are built-in   NIST calibration is included RS232 Interface For Digital Outputs and Configurable Device Options   Analog output zero and scaling can be set   Start/stop trigger levels for volume measurement can be specified   Update rate for LCD display and sampling rate for analog and digital outputs can be set   Selectable gas calibration   Set flow measurement for standard or volumetric   Volume computations TSI 4040 includes: Power Supply, Computer Cable (mini-DIN to 9-Pin D-Sub), Analog Cable (mini-Din to tinned-wire), RS232 Serial Command Set Manual, Operator’s Manual, Calibration Certificate, Inlet Filter Specifications: TSI 4040 Mass Flowmeter for Gases with LCD Gas Calibration Air, O2, N2, Air/O2 Mixture Inlet/Outlet Diameter 22 mm ISO tapered Flow Measurement Range 0-300 Std L/min Accuracy — Air and O2 ±2% of reading or 0.05 Std L/min, whichever is greater Accuracy — N2 ±3% of reading or 0.1 Std L/min, whichever is greater Accuracy — Air and O2 mixture ±3% of reading or 0.1 Std L/min, whichever is greater Response 4 ms to 63% of full scale flow LCD Display Units L/min, Std L/min Overall Dimensions 7.2” x 2.5” x 2.1” (182 x 63 x 53 mm) Volume* Measurement Range 0.01 – 99.9 liters Accuracy ±2% of reading (see Operator’s Manual for additional details) Pressure Measurement Range 50-199 kPa absolute Accuracy ±1 kPa Response <4 ms to 63% of final value for step charge Temperature Measurement Range 0-50°C Accuracy ±1°C at flow greater than 1 Std L/min Response <75 ms to 63% of final value for step change Outputs Analog 0-10 VDC flow only, zero and span adjustable via RS232 Digital RS232 *Supplied through RS232 port only. eBay Sales – Terms and Conditions Product Condition: All listed products are brand new, and come in the original packaging with a complete manufacturer’s warranty. Warranty: All Brand New products are covered by the Manufacturer’s Standard Warranty. The Standard Warranty usually applies to a one-year period, although some products come with a longer warranty. Please consult our Customer Care for more information. Payment Terms: PayPal is the main payment method. We also accept all major credit cards (Visa, MasterCard, American Express and Discover) for orders shipped within US. International customers are encouraged to pay via bank wire transfer. If you have questions regarding payment methods, quotes or any other matter related to sales, please contact our Customer Care department. Value Testers charges 8.3% sales tax for all shipments to Arizona addresses. Shipping: We only ship to addresses verifiable by either PayPal or credit card issuing bank. Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection. Orders normally ship within 1 to 2 business days, if placed before noon MST. Tracking numbers are provided automatically. We do inspect products before a shipment is made, and all shipments are insured. In case of international shipments, clients are responsible for any duties, import taxes and brokerage fees. Shipments to Alaska and Hawaii may carry higher rates. Please contact our Customer Care department for the detailed information on shipping to Alaska and Hawaii. Returns: Before returning product, please contact our Customer Care to receive RMA (return material authorization number). Returns without RMA will not be processed. Returns of non-defective items are subject to 15% restocking fee, if returned 14 days past the delivery date. The customer is responsible for the shipping charges of the returned products. All products must be returned in their original and undamaged manufacturer’s packaging with all accessories and product manual. Return may be voided, if product is returned damaged or marked, or if any accessories or parts are missing. Please make sure to insure the return shipment, as UPS only automatically insures shipments up to $100 value. Our Customer Care can answer your questions Monday – Friday, between 7:00AM and 5:00PM MST.  
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand TSI Alnor
MPN 4040
Model 4040

Directions

Similar products from Gas & Water Flow Meters

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies