Voltage Current Source Simulator 10v 20ma Process Loop Calibrator Auto Ramp H718

US $190.00

  • Shenzhen, China
  • Jun 9th
This calibrator is particularly suitable for  pneumatic actuators, hydraulic actuators, electric actuators,  electrical valve positioners and the valve positioners.   1. A quick-click knob for quick and easy one-hand operation; 2. Auto-Ramp Function can make the calibrator output a rhythmic-change current/voltage signal onto the outer load or loop equipment periodically  according to the time interval user sets.  3. “Source mA mode” can make the calibrator output current. 4. “Simulate mA mode” can make the calibrator simulate a two-wire transmitter with external power supply. 5. The calibrator can output a voltage signal, range from 0-100mV/0-10V with resolution 10uV.     Features The fast, one-handed tool for loop checks.  This feature-rich solution combines the best features push-button and knob-base loop calibrator and offers:    Large display and simple, quick-click interface for easy one-handed operation.    Simultaneous mA and % readout for quick, easy interpretation of readings.    mA accuracy of 0.025%, superior to other loop calibrators in this price range.    1 µA resolution for mA Source, Simulate and Measure.    Innovative output adjustment dial with 1 µA and 100 µA resolution.    0-100% “Span Check” for fast switch between zero and full scale point.    Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs  for valve slewing and loop functional tests. (Auto-Ramp Function provide single step(25%),slow or fast ramp output )   24 volt internal loop supply, so you can power and read a transmitter at the same time without  carrying a DMM.    Measures 0-10V DC & 0-100mV DC with accuracy 0.02%   Output 0-10V DC & 0-100mV DC with accuracy 0.02%   4 - 20 mA or 0- 20 mA output range could be set manually.   Rechargeable lithiumion battery pack.   Push button 25% steps for fast, easy linearity checks.    Specifications Current Measure Range: 0 to 24 mA Resolution: 0.001 mA Accuracy: 0.02% Rdg + 4 LSD Current Source Range: 0 to 20 mA or 4 to 20 mA Accuracy: 0.02% Rdg + 4 LSD Drive Capability: To 1200 ? at 20 mA  Current Simulate Range: 0 to 20 mA or 4 to 20 mA Accuracy: 0.02% Rdg + 4 LSD Ext. loop voltage requirement:  12-30 V Loop Power  While measuring mA, 24 V Voltage Measure Range: 0 to 10V DC Resolution: 1 mV Accuracy: 0.02% Rdg + 4 LSD mV DC Measure Range: 0 to 100mV   Resolution: 0.01mV   Accuracy: 0.02% Rdg + 4 LSD V DC Output Range: 0 to 10V Resolution: 0.001V Accuracy: 0.02% Rdg + 4 LSD mV DC Output Range: 0 to 100mV Resolution: 0.01 mV Accuracy: 0.02% Rdg + 2 LSD Environmental Specifications  Operating Temperature -10?C to 55?C Storage Temperature    -30?C to 60?C Humidity (Without Condensation) 0 to 90% (0?C to 35?C); 0 to 70% (35 to 55?C)   Note: we'll ship this item via express mail service and ePacket to USA, Canada, Australia,  New Zealand, Ireland, Austria, Belgium, Denmark, Germany, France, Finland, Luxemburg, Malta, Norway, Sweden,  Swiss, Spain, Italy, UK, Japan, Korea, Malaysia, Thailand, Indonesia, Philippine, Singapore. Clients from other countries pls contact with us in advance to confirm the different shipping charges before you bid.
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Model H718
Country/Region of Manufacture China
MPN H718
Brand generic
Country of Manufacture China
UPC Does not apply

Directions

Similar products from Process, Temperature & Pressure Calibrators

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies