X-ray Portable Siemens Mobilett Hp

US $6,000.00

  • Chicago, Illinois, United States
  • Feb 22nd
2001 Siemens mobilett HP is the leading model of the XP series, with 30 kW output power, motor-assisted drive and both mains and battery power operation.The self-calibrating high imaging output of 30 kW and 450 mA enables short exposure times down to one millisecond, virtually eliminating any motion blurring X-ray controls & generator MOBILETT XP MOBILETT XP Hybrid Power connection Grounded safety power socket (L/N/Gnd) Grounded safety power socket (L/N/Gnd) Line voltage 100–130 V ±10 %, 50/60 Hz, impulse current 11A, continuous current 0.6 A 200–240 V ±10 %, 50/60 Hz, impulse current 19A, continuous current 0.5 A 100–130 V ±10 %, 50/60 Hz, impulse current 11A, continuous current 0.6 A 200–240 V ±10 %, 50/60 Hz, impulse current 19A, continuous current 0.5 A Apparent resistance of supply AC line 100–130 V < 0.6 Ohm 200–240 V < 2.5 Ohm 100–130 V < 0.6 Ohm 200–240 V < 2.5 Ohm Output max. 133 kV 225 mA max. 450 mA 54 kV max. 30 kW – 99 kV – 303 mA – 10 ms max. 25 kW – 99 KV – 252 mA – 100 ms (IEC 60601-2-7) min. 0.32 mAs max. 133 kV 225 mA max. 450 mA 54 kV max. 30 kW – 99 kV – 303 mA – 10 ms max. 25 kW – 99 KV – 252 mA – 100 ms (IEC 60601-2-7) min. 0.32 mAs Over current release An on-site 15A/characteristic C overcurrent release (trip breaker) is recommended by DIN VDE 0100-710 for supply network voltages of 230 V/240 V. Country specific requirements apply for the fuse values to be used for other supply network voltages An on-site 15A/characteristic C overcurrent release (trip breaker) is recommended by DIN VDE 0100-710 for supply network voltages of 230 V/240 V. Country specific requirements apply for the fuse values to be used for other supply network voltages kVp range 40–133 kV in 24 or 49 stages 40–133 kV in 24 or 49 stages kV accuracy < ±3 kV (40–60 kV) < ±5 % (60–133 kV) < 3 kV (40–60 kV) < ±5 % (60–133 kV) mAs range: (Tube current and exposure time product) AC line operation 230 V At 40–55 kV: At 57–60 kV: At 63–66 kV: At 70–77 kV: At 81–85 kV: At 90–96 kV: At 102–109 kV: At 117 kV: At 125–133 kV: mAs 0.32–200 mAs 0.32–180 mAs 0.32–160 mAs 0.32–140 mAs 0.32–125 mAs 0.32–110 mAs 0.32–100 mAs 0.32–90 mAs 0.32–80 At 40–55 kV: At 57–60 kV: At 63–66 kV: At 70–77 kV: At 81–85 kV: At 90–96 kV: At 102–109 kV: At 117 kV: At 125–133 kV: mAs 0.32–200 mAs 0.32–180 mAs 0.32–160 mAs 0.32–140 mAs 0.32–125 mAs 0.32–110 mAs 0.32–100 mAs 0.32–90 mAs 0.32–80 mAs range: (Tube current and exposure time product) AC line operation 110 V At 40–55 kV: At 57–60 kV: At 63–70 kV: At 73–77 kV: At 81–85 kV: At 90–96 kV: At 102 kV: At 105–117 kV: At 125–133 kV: mAs 0.32–140 mAs 0.32–125 mAs 0.32–110 mAs 0.32–100 mAs 0.32–90 mAs 0.32–80 mAs 0.32–71 mAs 0.32–63 mAs 0.32–56 At 40–55 kV: At 57–60 kV: At 63–70 kV: At 73–77 kV: At 81–85 kV: At 90–96 kV: At 102 kV: At 105–117 kV: At 125–133 kV: mAs 0.32–140 mAs 0.32–125 mAs 0.32–110 mAs 0.32–100 mAs 0.32–90 mAs 0.32–80 mAs 0.32–71 mAs 0.32–63 mAs 0.32–56 mAs range: (Tube current and exposure time product) Battery operation for MOBILETT XP Hybrid At 40–81 kV: At 83–90 kV: At 93–102 kV: At 105–117 kV: At 121–133 kV: mAs 0.32–360 mAs 0.32–320 mAs 0.32–280 mAs 0.32–250 mAs 0.32–220 mAs accuracy 0.32 mAs–2 mAs: ± 0.1 mAs, > 2mAs: ± 5% 0.32 mAs–2 mAs: ± 0.1 mAs, > 2mAs: ± 5% Shortest exposure time 1 ms 1 ms Max. exposure time 3.5 s 5 s Length of power cable 6 m retractable cord 6 m retractable cord Exposure release Detachable hand switch with 5 m (16.4 ft) of spiral cord Optional: IR-Remote Control Detachable hand switch with 5 m (16.4 ft) of spiral cord Optional: IR-Remote Control Weight Approx. 206 kg Approx. 294 kg Dimensions: Footprint (l x w x h) (Tube in park position) 98.7 x 57.5 x 155 cm (39 x 23 x 61 inch) 98.7 x 57.5 x 155 cm (39 x 23 x 61 inch) Tube positioning Max. focal spot height 2135 mm (84.1 inch) Min. focal spot height 478 mm (18.8 inch) Max. horizontal ext. 1285 mm (50.6 inch) Min. horizontal ext. 282 mm (11.1 inch) Max. focal spot height 2135 mm (84.1 inch) Min. focal spot height 478 mm (18.8 inch) Max. horizontal ext. 1285 mm (50.6 inch) Min. horizontal ext. 282 mm (11.1 inch) Enclosure protection type Not protected (IPX0) Not protected (IPX0) Protection against electrical shock Class I, acc. to IEC 60601-1 Class I, acc. to IEC 60601-1 Tube housing MOBILETT XP, MOBILETT XP Hybrid, MOBILETT XP Eco Stabilization Microprocessor-controlled adjustment and regulation during exposure X-ray tube Siemens P135/30 R with nominal focal spot value 0.8 (acc. to IEC 60336) Anode rotation 9,000 r.p.m., 142 Hz (anode angle 15°) Anode heat storage capacity 90,000 J = 122,000 HU Tube housing heat storage capacity 800,000 J = 1,100,000 HU Inherent filtration • Collimator • Tube housing assembly • Total min. 2.0 mm Al (at 70 kVp) min. 1.9 mm Al (at 70 kVp) min. 3.9 mm Al according to IEC 60522 Collimator Manually adjustable multileaf collimator, rotatable ± 90° Collimator light and light field intensity Halogen lamp min. 180 lux at 1 m SID, without DAP equipment Tube housing assembly Max. temperature 60 °C, max. 2000 mAs/h, nominal continuous rating 75 W until the covers reach 60 °C Measurement of leakage radiation* 133 kVp/10 mAs, 200 exposures/h Motor drive MOBILETT XP Hybrid only Drive speed Low/high, adjustable 0.5–1.35 m/s Max. incline 7° Batteries MOBILETT XP Hybrid only Batteries 168 Ah total capacity Automatic battery charging with charge indicator AC line operation with reduced output power 24 sealed maintenance-free lead batteries, Yuasa: NP 7-12L Charging time 4-5 h (typical), 12 h when completely discharged Remote control (optional) MOBILETT XP, MOBILETT XP Hybrid, MOBILETT XP Eco Compatibility Compatible with all TechSwitch remote exposure switch systems Technology Infrared light beam, line-of-sight operation, will operate through glass and lead glass, will not operate through doors or walls Power supply of the remote control 9-volt alkaline battery included, 25,000+ exposures, low battery indicator illuminates when battery needs to be replaced Operating distance Up to 36 feet (10.9 m) Operating radius 180°; remote sensor built into the front arm of X-ray unit DAP equipment (optional) MOBILETT XP, MOBILETT XP Hybrid, MOBILETT XP Eco Technology Ionization chamber, display and control panel Typical filtration < 0.4 mm Al equivalent Warm-up time Ready for use 10 seconds after power on. Specified accuracy achieved 15 minutes after power on Chamber light transmission >= 70 % DAP resolution 0.1 ?Gym2 Max. measurable DAP 1 x 106 ?Gym2 Environment Operation Transport/Storage Permissible ambient temperature Permissible relative humidity +10 °C – +40 °C 30 % – 75 % -20 °C – +70 °C 10 % –100 %
Condition Used :
An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections.
Seller Notes used system in tested and working condition.

Directions

Similar products from Sensors, Cameras & X-Ray Systems

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies