12.1" Touch Vital Signs Monitor Icu Ccu Patient Monitor Ecg Nibp Resp Temp Spo2

US $503.00

  • Hebron, Kentucky, United States
  • Sep 4th
Description: This Patient Monitor can monitor parameters such as ECG, RESP, SpO2, PR, NIBP and TEMP.It integrates parameter measuring modules,display and recorder in one device,featuring in compactness,lightweight and portability. Replaceable built-in battery facilitates transportation of patient. Features: 12" high resolution color TFT LCD display,wide viewing angle. Touch screen operation,which improves the working efficiency for medical staff. With standard interface,big character interface and view bed,convenient to observe. Suitable for adult,pediatrics and neonate patients. Can be arbitrarily set the alarm limit, automatic sound and light alarm Anti-movement, anti-defibrillation, anti electrosurgical interference Drug solubility calculation function, Arrhythmia analysis function Built-in lithium battery, AC and DC,can provide uninterrupted monitoring. This medical equipment can be used in ICU, CCU and operation room. Standard configuration: EC, NIBP, SPO2, TEMP, RESP,PR Specification: ECG Lead Mode:5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V) Lead selection:I, II, III, avR, avL, avF, V, Waveform:2 ch Lead mode:3 Leads ( R, L, F or RA, LA, LL) Lead selection:I, II, III, Waveform:1 ch Gain:2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, auto HR and Alarm  Range:  Adult:15 ~ 300 bpm Neo/Ped:15 ~ 350 bpm Accuracy:± 1% or ± 1bpm,which great Resolution:1 bpm Sensitivity:> 200 (uV P-P) Differential Input Impedance:> 5 M RESPARATION: Method:Impedance between R-F(RA-LL) Differential Input Impedance:>2.5 M Measuring Impedance Range:0.3~5.0 Base line Impedance Range:0 – 2.5  K Bandwidth:0.3 ~ 2.5 Hz Resp. Rate Measuring and Alarm Range  Adult:0 ~ 120 rpm Neo/Ped:0 ~ 150 rpm Resolution:1 rpm Accuracy:±2 rpm Apean Alarm:10 ~ 40 S NIBP Method:Oscillometric Mode:Manual, Auto, STAT Measuring Interval in AUTO Mode  1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min) Measuring Period in STAT Mode:5 Min Pulse Rate Range:40 ~ 240 bpm Alarm Type:SYS, DIA, MEAN Measuring and alarm range:    Adult Mode SYS :40 ~ 270 mmHg DIA :10 ~ 215 mmHg MEAN:20 ~ 235 mmHg Pediatric Mode SYS:40 ~ 200 mmHg DIA:10 ~ 150 mmHg MEAN:20 ~ 165 mmHg Neonatal Mode SYS:40 ~ 135 mmHg DIA:10 ~ 100 mmHg MEAN:20 ~ 110 mmHg Overpressure Protection Adult Mode:297±3 mmHg Pediatric Mode:240±3 mmHg Neonatal Mode:147±3 mmHg SpO2 Measuring Range:0 ~ 100 % Alarm Range:0 ~ 100 % Resolution:1 % Accuracy:      70% ~ 100%  ±2 % 0%  ~  69%  unspecified Actualization interval:about 1 Sec. Alarm Delay:10 Sec. Pulse Rate Measuring and Alarm Range:0~254bpm Resolution:1bpm Accuracy:±2bpm I.5TEMP measurement: Channel:1 Measuring and Alarm Range:0 ~ 50 °C Resolution:0.1°C Accuracy:±0.1°C Actualization interval:about 1 Sec. Average Time Constant:< 10 Sec. Package List: 1Patient Monitor 1EKG Lead wire 1NIBP Cuff 1NIBP Extension Cable 1SpO2 Sensor 1Temp Sensor 1Ground Cable 1Power Cable 5Electrode 2Fuse 1User Manual(CD)  
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Model 800207
Monitor Parameters ECG
Features Touchscreen
Brand Unbranded
MPN Does Not Apply
UPC Does not apply

Directions

Similar products from Health Condition Monitors

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies