12 Channel 24 Hours Recording Time Ecg Holter Ecg( Dcg) Systems+pc Software

US $899.00

  • Qinhuangdao,Hebei, China
  • Jan 30th
                                                             12 Channels ECG Holter ECG/EKG Holter Monitor System                Manufacture : CONTEC Medical System         Model :   TLC 4000                    Recorder Features With advanced design and technology, the recorder can work stably, dependable and durable. Be provided with the capability of anti-jamming and shock-pro. Small volume, light weight, low power consuming, convenient to take. Reading and writing can be more faster and memory can be larger by using flash to storage data. Record waveform details inextenso by the design of high precision and sampling frequency. Record the state of pacemaker exactly by higher sampling frequency. International standard of 12 leads. Record 24-hour DECG with the same standard of the ECG.   Software Features Quick and accurate analysis system. With 12 leads synchro analysis , QRS search can be more exactly. There are more than 10 templates as atrial premature beat module, ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc. and multiplicate User-defined templates could almost identify every kind of pathologic waveforms. Optional main channel. Agile and exact "Atrial Fibrillation" analysis. The function of pacing analysis could analyse all pacemakers.  Many pacing modules have been added. Any period of single lead or 12-leads ECG can be reviewed at any time with the function of fast waveform review and analysis. The types of the analysis system of HR variability include five minutes of short ECG and one hour or 24-hour of long ECG. Print report expediently. Perfect function of case management.   With the function of ST segment analysis and general load of the disorder of the heart muscle, the physician can judge a disease or disorder of the heart muscle generally. "Sleep breath pause syndrome analysis", the physician could print sleep asphyxia analysis report and diagnose. "HRT" analysis, when the adjustable function is natural, this transitory change will be represented by the form of HRT immediately. "T Wave alternation" analysis is a important index on judging and preventing Arrhythmia .  The report has more reference value with the functions of VCG, VLP, TVCG and QTD analysis. Standard Specifications Number of channels: 12 channels; Sampling rate: 10000HZ; Sampling accuracy:12 bit; Recording time : 24 h; Power: 2 batteries in size 5; Interface: USB2.0; Scale voltage:1mV±5%; Standard Sensitivity:10mm/mV±5%; Noise level:=60dB; Feathers of low frequency : Time constant>3.2s; Scan speed:25mm/s±5%; Enduring polarization voltage:±300mV; Least measure signal : 50 µV p-p; Product safety type : Type B (Internally powered).   Content  1 Holter recorder 1 CD of software 10 pieces of patient cable 10 pieces of disposable ECG sensor 1 porch for hanging recorder 1 USB cable for data download  Instruction manual paypal payment   We only accept paypal payment, please be kindly make payment  in 7 days. 1. We will ship the item within 48 hours after receiving your payment, please kindly leave your detail shipping address and telephone number on ebay and paypal, both are very important for the shipment, thank you. 2. Usually we will ship by EMS or UPS or TNT ,that's depends on your country.Usually it will take 7  working days to arrive at your     country.If you have special requirements about the shipping company, please contact me immediately after your payment, leave the note in both ebay and  paypal, thank you. 3. We will upload the tracking number after shippment, you can search from both ebay and paypal. You can track online. 4. If you haven't received the item after 2 weeks of your payment, please contact me immediately!    Please kindly leave  your right information about address,  telephone number, color and all requirements. Return: If your item arrived damaged or defective or if you  received the wrong product or the item is not working according to its technical spec, you may return it  to us for a replacement item or a full refund, This should be done within 14 days from the day you received  the item. We will send you a new unit or refund the full  payment you paid. Custom fee: International Buyers - Please Note:  •       Import duties, taxes and  charges are not included in the item price or shipping charges.             These  charges  are the buyer's  responsibility.  •       Please check with your  country's customs office to determine what these additional costs           will be prior  to  bidding/buying." Warranty: 3 years (1 year for spare parts) from the date of  shipment under normal use and service.  By Airmail:  Generally, about 2-3 weeks to UK, USA,  AU.  By Express: Generally, about 5-10 working days to  UK, USA, AU.  delivery to US, UK, Australia and Canada usually  takes 7-14 working days;  delivery to countries except US, UK, Australia and  Canada usually takes 7-21 working days;  We can also ship the item through express service  like DHL, UPS, if you are ready to pay the  extra charge.  To know the details please contact us with  email. Refund: Agent  in the world! We are  looking for partners in the world now! Do you  want  to become our agent in you country? Join  US!   Please  contact : Daisy  

Directions

Similar products from Other Diagnostic Tools

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies