12" Icu Patient Monitor 6 Parameter Vital Sign Ecg Nibp Resp Temp Spo2 Pressure

US $1500

  • BEIJING, BEIJING, China
  • Jan 30th
Description: HOT NEWS : Buy it now , you will get 3 years warranty contact me now ,you will get a discount 12-inch ICU CCU 6-parameter Patient Monitor with ECG, NIBP, SPO2, TEMP, RESP, PR If you need buy thermal printer+ETCO2 module, please contact me for details .we can customize for you .     Features for Patient Monitor:     Ergonomic design, portable, convenient for use 12" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters Unique digital SPO2 technology can work accurate during motion and low perfusion Anti AC & high-frequency electrosurgical & defibrillator’s interference Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation Audible & visual alarm available, adjustable Patient information management function Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room Optional software upgrading based on USB Wired/wireless networking with central monitoring system, up to 64 beds in one group Built-in 3 trace thermal recorder for printing real-time and historical data Multi-language i.e. English, Spanish, Turkish. Super long life rechargeable Lithium battery upto 4 hours of working time Suitable for adult, pediatrics and neonate patients Standard configuration:    ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery Optional:     Dual TEMP Dual IBP ETCO2 (side stream)  Thermal recorder Wall mount Trolley Specification for Patient Monitor:       ECG Full lead: I, II, III, AVL, AVR, AVF and V Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s Band width: 0.05Hz-100Hz(3dB) Heart rate:  Scope: 15 times/minute to 300 times/minutes Accuracy:  ±1 time/minute Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.  Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.    Accuracy: Error rate < 20%          Undetected rate < 20%  ST section  Scope:     ±0.8mV Precision :  < ±0.05mV SpO2 Detection scope:   0%-100% Accuracy         ±1%     90%-100%                                 ±2%      70%-89%  NIBP  Theory Electric oscillator  Cuff gassing time   less than 15 seconds First-time gassing pressure: dynamic state 24kPa(180 mmHg) Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg) 18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg), Automatic detection period: 1 minute to 240 minutes  Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m in -90min) and 30min(90 min -240min) Detection scope:  Systolic blood pressure:   4kPa -34kPa(30mmHg -255mmHg) Diastolic pressure             2kPa -29.3kPa(15mmHg -220mmHg) Mean pressure               2.7kPa~31.3kPa       (20mmHg~235mmHg) Detection accuracy  Static pressure: ±3mmHg Pulse rate:  ±2% Resp Chest impedance method or concentration of carbon dioxide at end of respiration  Scope of chest impedance method     0 time/minute – 100 minutes/minute  Precision of chest impedance method  time/minute  Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby) Detection precision of respiration rate: ±1 time/minute  Temp Single/double path  Type:    Vascular/surface temperature  Scope:    20°C~50°C Accuracy:  ±0.2°C   Invasive blood pressure (optional)   Single/double path  Type: direct and continuous detection  Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg) Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg)  13.33k Pa(100mmHg) above ±2% Frequency response:DC-12Hz Input resistance: not less than 500k? Sensitivity of sensor: 5?V/V/mmHg Motivation voltage:5V (DC) Accuracy of sensor: ±2%Isolation voltage: 4 kV    

Directions

Similar products from Health Condition Monitors

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies