12v 24v Dc Digital Voltage Meter Test Control Relay Timer Delay Switch Module

US $300

  • HONG KONG, Hong Kong
  • Mar 11th
Welcome to my ebay store! You will find your favorite products. Pass by do not miss.thank you! Product Detail Description: 100% Brand New and High Quality   Thank you for using this product of our company, the “EAZY-IV-U3” controller is compatible with a variety of operating modes, LED digital displays, procedures for intelligent control, has a voltage detection channel, a set of relay switch output (normally open and normally closed), the time relay can be controlled by voltage detection to achieve a variety of functions. In case of any printing or translation error, we apologize for the inconvenience.   Product Features:   Operating modes: P-1: Relay close delay time and display off setting P-2: Voltage Control Timer- A (release first) P-3: Voltage Control Timer- B (close first) P-4: Voltage range control Timing range: 0-999 seconds Voltage display range: DC 0-99.9 V Voltage detection error: ± 0.1V Operating Power: DC 8~35V   Relay parameters: A set of conversion (normally open and normally closed) Contact load: 10A/277V AC or 10A/30V DC Contact resistance: ≤ 100mΩ (1A 6VDC) Mechanical durability: 10 millions Electricity durability: > 100,000 (10A-250VAC) Operating Temperature: -40 ~ 85℃ Set display shut, the minimum current values are 7mA/12V (delay released) The pre-set parameters can be saved after power off.   Mode of introduction:   P-1 delay setting:   Into the P-1 mode, the user can set the delay time relay release T1, pull time T2 (0-999 seconds), the digital display off delay time, if the release time of the relay is set to 005, pull time is set to 000, then the relay 5 seconds after the release has been delayed pull, if the release time is set to 000, pull time is set to 005, then the relay is energized immediately, 5 seconds after release, if the relay release time is set to 005, pull time is set to 006, then the relay is energized after a delay of 5 seconds to release the final six seconds.   When the digital closed minimal standby current of 6mA / 12V. Display "d-0", said the digital tube off time is 0, that is always on, press ENTER to set a 1-9 minute delay, in either mode, when there is no key operation digital automatic delay off, there keystrokes when the digital display will illuminate and delay off. P-2 voltage detection control (initial release):   Into the P-2 mode, the system real-time acquisition "voltage detection +" and "GND" DC voltage between the terminals and displays, when the voltage is higher than the value of the detection limit set on the relay, below the lower limit release can also be set higher than the upper limit of the relay release, below the lower limit pull. Voltage Detection range: DC0 ~ 99.9V. Relay load: 10A 277AC / 30VDC, pay attention to the DC load voltage exceeds 30V, DC high voltage arcing may damage the relay contacts, and therefore need an external DC solid state relays.   If you set the delay time in P-1, the start of the relay will be set according to delay action, such as   The next P-1 mode is set to release time T1 is 003, then the detection voltage reaches the relay start value, the relay will delay 3 seconds and then pull. This method can be used to detect the voltage-delay function.   Example 1: P-1 mode is set to T1 000 T2 000, P-2 mode is set to "ON H", then when the detected voltage is higher than the upper limit, the relay immediately pull detection voltage is below the lower limit, the relay immediately released .   Example 2: P-1 mode is set to T1 003 T2 000, P-2 mode is set to "ON H", then when the detected voltage exceeds the upper limit, the relay will be delayed by three seconds after disconnecting become energized.   Example 3: P-1 mode is set to T1 003 T2 000, P-2 mode is set to "ON L", then when the detected voltage is below the lower limit, the relay will delay 3 seconds after the release becomes energized.   Example 4: P-1 mode is set to T1 003 T2 002, P-2 mode is set to "ON H", then when the detected voltage is higher than the upper limit, the relay will delay 3 seconds before pull two seconds, then release .   P-3 voltage detection control (initial pull):   P-3 and P-2 mode setting mode, and exactly the same argument, only the initial state the contrary, P-2 mode relay initial release, and P-3 relay mode initially, mainly for off-delay feature, when setting up state relay "ON H", the timer starts when the detected voltage is higher than the upper limit below the lower limit relay, when "ON L", the detected voltage is higher than the upper limit of the relay , below the lower limit, following start the timer, e.g., in the P-1 mode is set to release the first set time T1 000, a second set of pull-in time T2 is 003, then when the detected voltage is higher than the upper limit of starting a timer, relay will delay 3 seconds and then disconnected.   Example 5: P-1 mode is set to T1 000 T2 003, P-3 mode setting "ON L", then when the detected voltage is below the lower limit, the relay will delay 3 seconds after the pull becomes disconnected.   P-4 over-voltage control (voltage limit alarm):   Under P-4 mode can be set to detect the voltage on the inner lower range pull or release, exceeding the upper and lower range to start the timer (P-1 execution set parameters to run), if at P-4 mode setting relay status when "ON H", the detection voltage is within the upper and lower range relay, set to "ON L" is detected in the upper and lower limit voltage relay release.   Example 6: P-1 mode is set to T1 003 T2 000, P-4 mode is set to "ON L", then when the detected voltage exceeds the upper and lower limit, the relay will be delayed by three seconds after disconnecting become energized. Under P-1 mode is set T1 000 T2 003, P-4 mode setting "ON H", then when the detected voltage exceeds the upper and lower limit, the relay will delay 3 seconds after the pull becomes disconnected.   Package Included: 1x English instruction (if you need ,send to you email) 1x DC Digital Voltage Meter Test Control Relay 8-35V with case Feedback > We maintain hightest buyer ratings > Positive Feedback will be much appreciated from you. > Any dissatisfaction, please contact us immediately! > Please do not leave neutral or negative feedback before we help you out. Payment > We accept PayPal only. > All major credit cards are accepted through secure payment processor PayPal. > Payment must be received within 7 days of auction closing. Shipping > We Ship to Worldwide, except Hong Kong, Italy, Nigeria..... > Items will be shipped within one business day on payment received. > Items are shipped from China using Airmail, delivery time depends on destination and other factors,reach most of the countries within 10 to 35 business days. Country Shipping Way Shipping Time Tracking Number United States USPS(ePacket)   7-12 Yes Russian China Post 15-35 Yes Other Country HK /Swiss Post Air Mail 15-45 No Brazil / Africa HK /Swiss Post Air Mail 25-55  No  Returns > Defect: We will fully refund or send you a new replacement,please contact and return within 14 days. > Dissatisfaction: Please contact within 3 days, we will fully refund, after got your returned goods. > Missing parts/Q'ty: Please contact us immediately,for a new package arranged,or a partial refund issued. Contact us > If have any question, Please contact us by ebay message before leaving neutral, negative feedback or open any dispute, we will reply within 24hours, ensure that help you solve the problem, make you satisfied. > Our Working-time From 8:30 AM to 21:30 PM(GMT+08).  Engineered for professional eBay sellers!
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Model EAZY-IV-U3
Contact load 10A/277V AC or 10A/30V DC
Operating Power DC 8~35V
Contact resistance <= 100m? (1A 6VDC)
Timing range 0-999 seconds
English instruction YES(send to you email)
Voltage display range DC 0-99.9 V

Directions

Similar products from Relay Module Boards

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies