2007 Ziehm Vista Plus C Arm

US $3600

  • Kaysville, Utah, United States
  • Oct 23rd
2007 Ziehm Vista Plus C Arm We are selling a 2007 Ziehm Vista Plus C Arm. If you are looking for a quality 9" II system with DSA, 30 fps and Cine Loop options look no further. Compare the specifications and you will find value. Ziehm Vista with a cesium iodide 9/6/4" Image Intensifier  X-ray tube: stationary-anode tube  Dual focus: 0.6/1.5 mm  Fluoroscopy: 40 -110 kV, 0.2 -6 mA  Digital radiography (snapshot): 40 -110 kV, 8 mA  Radiography: 40 -110 kV, 20 mA  Super-high-resolution and high-brightness twin flat-screen monitors  – screen size: 18.1“ (46 cm)  – native resolution: 1280 x 1024 pixels  – viewing angle (horizontal & vertical): 170°  – contrast ratio: 800:1  – dimensions: 41 x 34 x 7 cm  DICOM 3.0  Laser aimer  USB Data Export File Save  Today’s hospitals are faced with an ever-increasing demand for medical procedures to be performed, especially in the areas of minimally invasive and interventional surgery. As the cost of healthcare continues to rise, hospitals are required to work as cost and profit driven enterprises. Each capital acquisition therefore follows a carefully considered evaluation process to determine the most cost and benefit-efficient equipment. With Ziehm Vista – the most versatile mobile C-arm – the selection process is made easy. Offering outstanding functionality in terms of image quality, user interface and dose savings Ziehm Vista can be used for a wide range of fluoroscopic imaging applications. With its proven mobility and fully developed connectivity, working with Ziehm Vista results in increased efficiency and lower total cost of ownership. Benefit from Superior Imaging Technology: Image Quality is clearly the most important feature of any mobile C-arm. The Ziehm Vista development team intensively reviewed the Vista’s entire video chain – from the camera, through every element of the Ziehm Video Signal Processor – to the standardly integrated 18” flat screen displays.The result is optimized image quality for every type of procedure. Ziehm Vista’s Full Frame techno logy eliminates poor image definition and generates excellent, interference-free images. Choose Your Anatomical Program: The Anatomical Programs found in every Ziehm Vista optimize image quality to each body region using the lowest possible dose. Choose between the ‘Extremities’, ‘Spine’ and ‘Thorax’ Anatomical Programs to ensure superb image quality in each type of procedure. In addition, unique ‘Metal’ and ‘Soft’ imaging programs further enhance image quality in otherwise difficult imaging conditions. Considerate Use of Radiation. Wherever you look on the Ziehm Vista, you will find features that can significantly reduce the radiation dose delivered to the patient, the physician and personnel within the operating theatre. Every Ziehm Vista includes specialized x-ray filters, which, in conjunction with the non-interlaced CCD camera, decrease the patient dose considerably with no loss in image contrast. In addition, the following features ensure that Ziehm Vista is one of the most patient-friendly mobile fluoroscopy systems available: • Full Frame Technology • Digital image rotation and reversal without radiation • Virtual collimation without radiation • Anatomical Programs • Pulsed fluoroscopy with last image hold • Patient dose recording • Half-dose mode • Laser cross-hair positioning and centering Extending the Capability of Your Unit: The Ziehm Vista offers a comprehensive range of system options and configurations to meet the needs of a wide range of applications. With a modular upgrade path, a standard Ziehm Vista ‘Ortho’ model can be re-equipped up to the highest specification ‘Vascular’ model. Ease of Use: Clear, one-touch controls and a high level of automation allow you to concentrate on positioning, while your Ziehm Vista’s computer system takes care of all imaging parameters. At the monitor cart, helpful on-screen prompts guide you through tasks, so that you can make maximum use of the systems comprehensive features without the need for extensive training. Following image acquisition, a wide range of sophisticated postprocessing functions can be performed quickly and simply using one-touch menu driven options. Image Storage and Hardcopy: Once acquired, images can be stored on different media such as Hard Disk, Floppy Disk or CD-ROM to provide the medical team with a convenient, portable record of the image data from a procedure. The monitor cart can accommodate a range of high quality video paper or film printers as well as a video recorder, to provide you with all the image documentation you may require. Perfect Clinical Mobility: Featuring one of the smallest footprints and reduced weight characteristics available, the versatile Ziehm Vista is the perfect choice for any surgical imaging application encountered during your working day. Equipped with new wheels and precision bearings, Ziehm Vista provides even easier movements with the absolute minimum of effort. This benefits the user from a reduced possibility of stress-related injury and provides a more pleasant working experience. Focusing on the mechanical precision of the C-arm’s orbital rotation, angulation and swivel movements, Ziehm’s research & development team highlighted new design improvements in the mechanical control of the C-arm. The resulting ergonomically shaped handles and levers provide the highest level of user friendliness available. Unsurpassed Positioning Capability. All C-arm movements are fully counter-balanced in all positions, making the C-arm stable even when the locks are disengaged, allowing a fast and effortless change of projection during intraoperative examinations. The C-arm’s ease of movement from one position to another is smooth and fast, requiring little effort on the part of the user and having one of the largest C-arm dimensions to be found. And if your speciality is pain management or spinal orthopedics, the optional 45° forward orbital rotation as well as 20 cm vertical lift extension allow Ziehm Vista’s C-arm to adopt the extreme positioning angles required in many of these procedures. Exceptional Digital Network Integration. Ziehm Vista features the unique and fully integrated Ziehm NetPort using DICOM 3.0 communication protocols. Running via Primary Capture mode Ziehm NetPort is capable of transferring original images and patient data to and from PACS or HIS/RIS to provide you with a completely integrated digital network solution. Using DICOM Image Retrieve module found in Ziehm NetPort, the surgical team benefits from total access to all image information available from your PACS. This eliminates the need for an additional workstation or monitor. Ziehm NetPort also uniquely manages DICOM Multiframe Class, allowing the transfer of dynamic image sequences to and from the operating theatre. Ziehm Imaging provides the most comprehensive access to the DICOM world, with the following range of DICOM Classes available: • Storage Class incl. Storage Commitment • Print Class • Media Class • Worklist Class incl. MPPS • Query Function • Image Retrieve • Verification Class Integration with Image Guided Surgery (CAS). Ziehm Vista is designed to integrate the latest Computer-Aided Surgery (CAS) systems. In combination with Ziehm Vista it forms a surgical environment with real time image-guidance, allowing surgeons to operate with optimal precision and accuracy. In CAS the x-ray image becomes a road map of the patient’s anatomy that is correlated to the real-time position of the surgical instrument. The surgeon follows the instrument’s movements without requiring continuous x-ray imaging of the patient. This technology has its biggest impact in brain and spinal surgery as well as orthopaedics. Guaranteed connectivity of C-arms is important in this field, as proven compatibility with various CAS systems is essential for success. In this way, CAS and mobile C-arm systems can be chosen independently in order to best benefit local requirements. Ziehm Vista is proven for use with all leading fluoroscopic CAS systems, such as those from Medtronik-Sofamor-Danek, Brainlab and Medivision. Please contact us with any questions. California residents please contact us prior to bid/purchase.  The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipment. Payment Shipping Returns We Accept: Paypal Wire Transfer Visa/Mastercard American Express Cash on Pickup All items will be professionally packed or crated to ensure safe transport and shipped within 2 days of payment.  Larger items requiring a crating, specialized packaging, or items awaiting BioMed certification, will ship within 3-5 day of payment.  Please contact us with any question regarding the shipment of a purchase. Combined shipping discounts are available for multiple item purchases.   We will ship International; Please note that Customers/Buyers are responsible for any customs duties, taxes, tariffs or any other charges as such on items being shipped to a foreign country. If the item is shipped to a U.S. exporter, once it is received by the exporter we are no longer responsible for the item. Items Must Be Returned Within:  14 Days unles item is sold as is not return. Please check listing prior to bidding. Refund Will Be Given As:  The same payment method as the item was purchased. Refunds Refunds will be issued within 7 business days after the receipt of the equipment. All returned items must be in original condition, packaging, sealed and unused, tamper tag must be intact. We reserve the right to reject the item after inspection, (items with physical damage or incomplete packaging, incomplete items). In the event that physical damage is caused during transit of a return, it is the customers’ responsibility to contact the carrier to start a damage claim upon receiving a notification from us. The responsibility is between the customer and the carrier. Items being sold as "For Parts Only" are sold as final sale. No returns will be accepted. Details:  If we have made a mistake, let us know, and we will do everything we can to make it right.  If not, there is no restocking fees, but the buyer assumes responsibility for the returning shipment and its cost. Primis Medical LLC 695 North Kays Drive Suite 3 Kaysville, UT 84037 1-385-319-7104 Please contact us with any questions. California residents please contact us prior to bid/purchase. The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipment.

Directions

Similar products from Imaging Esthetics Devices

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies