TLC 9803 SERIES Holter ECG ( DCG) Systems We are glad to send DOMO of this device if you enquiry it ! Description Recorder Features ? With advanced design and technology, the recorder can work stably, dependable and durable. ? Be provided with the capability of anti-jamming and shock-pro. ? Small volume with OLED screen. The resolution is 160*128. ? Be provided with functions of waveform preview, record review and event marking. ?Accurate record of the start time of the data sampled owing to the real time clock of itself. ?Avoid damage owing to the repeating inserting and pulling out by using the inbuilt TF card to storage the data. ?The maximum capability can be 2GB, so the original data can be saved perfectly by no compression. ?The average review time of single case can be less than 40 seconds by using interface of USB 2.0. ?Record waveform details inextenso by the design of high precision and sampling frequency. ?Record the state of pacemaker exactly by higher sampling frequency. The features of software ?Quick and accurate analysis system. ?With 3 leads synchro analysis, QRS search can be more exactly. ? There are more than 10 templates as atrial premature beat module, ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc. and multiplicate User-defined templates could almost identify every kind of pathologic waveforms. ?Optional main channel. ? Agile and exact "Atrial Fibrillation" analysis. ?The function of pacing analysis could analyse all pacemakers. ? Many pacine modules have been added. ? Any period of single lead or 3-leads ECG can be reviewed at any time with the function of fast waveform review and analysis. ? The types of the analysis system of HR variability include five minutes of short ECG and one hour or 24-hour of long ECG. ? Print report expediently. ? Perfect function of case management. ? With the function of ST segment analysis and general load of the disorder of the heart muscle, the physician can judge a disease or disorder of the heart muscle generally. ?"Sleep breath pause syndrome analysis", the physician could print sleep asphyxia analysis report and diagnose. ?"HRT" analysis, when the adjustable function is natural, this transitory change will be represented by the form of HRT immediately. ?15."T Wave Alternation" analysis is a important index on judging and preventing arrhythmia. Standard Number of channels: 3 channels; Sampling rate: 10000Hz; Sampling accuracy:12bit; Recording time : 24 h; Power: 2 batteries in size 5; Interface: USB2.0; Scale voltage:1mV±5%; Standard Sensitivity:10mm/mV±5%; Noise level:=60dB; Feathers of low frequency : Time constant>3.2s; Scan speed:25mm/s±5%; Enduring polarization voltage:±300mV; Least measure signal : 50 µV p-p; Product safety type : Type B (Internally powered); Size:111mm(L)*60mm(W)*25mm(H); Net Weight: 102g (Without battery). Inside The Box ? 1 Holter recorder ? 1 CD of software ? 10 pieces of patient cable ? 10 pieces of disposable ECG sensor ? 1 porch for hanging recorder ? 1 USB cable for data download ? Instruction Manual ? 2 year warranty Features: ?Compact size, light weight ?Fully programmable, high Fidelity ?Lower power consumption?Fast data transfer ?Pacemaker detection Holter Analyzer Software: CardioScape Holter Functions & Features: QRS Templates Apply Demix technology, ensures the accuracy of QRS templates, includes N (Normal), V (Ventricular Ectopy), S (SVE), U (Unknown), P (Pacemaker), A (Artifact). All the templates can be combined or separated as individual beats. beats can be superimposed. Weak signal can be identified such as P wave. ? Arrhythmia Analysis VE, SVE, aberrant beats, V-Tach, V-Pair, V-Bigeminy, Tri-geminy etc.. ? HRT (VE Chaos) Analysis HRT is the most powerful ECG-related risk predictor for assessing the death risk following myocardial infarction. The predictive value is comparable with that of the LVEF. ?Pacemaker Analysis Unique pacemaker analysis is suitable for various models i.e. AAI, VVI, DDD, DDR pacemakers. ?HRV (Heart Rate Variability) Analysis Time domain and Spectral domain HRV analysis, superlower HRV analysis.(Heart Rate Variability is analyzed in both Time Domain and Frequency.The top of the HRV display shows the Poincare-Lorenz scatter plots. The lower left shows the Frequency power graph. The range boundaries for LF, LF and HF can be adjusted. The lower right shows the Time Domain histogram. Day and night times can be entered for Sleep Apnea and for A-Fib.) ?Atrial Fibrillation and Atrial Flutter Analysis Atrial Fibrillation is very important for the cardiologist concern. Holter ECG is an excellent test to detect transient A-Fib. ?OSAS (Obstructive Sleep Apnea Syndrome) Analysis Using Holter test to detect the OSAS earlier and cost-saving. ?ST Analysis ST analysis trends, form and support report, identify ischemia location. ? TWA (T-wave alterans) Analysis Unknown for the past 40 years, T-Wave Alternans (TWA) in excess of 20 micro-volts have been in Holter recordings but have been undetected.TWA is a strong predictor of V-Tach and other serious cardiac abnormalities. It takes less than 10-seconds to do a complete 24 hours TWA analysis. You cancheck for TWA anywhere in teh 24hours ECG file. Not only can you detect TWA in the ECG file, this software lets you view the ECG showing the actual TWA, so that you can verify and validate the presence of real TWA. The TWA algorithm detects two modes of TWA. Mode 1 is the beat-to-beat change in T-Wave amplitudes exceeding 20 micro-volts, as shown in the adjacent picture. Mode 2is the gradual up and down changes of T-wave amplitudes over a series of several beats. Other ECG machines: ECG100G ECG80A ECG90A ECG300G ECG600G ECG1200G ECG1201 ECG Holters TLC9803 TLC5000 TLC6000 Payment Paypal account: contecgyj@gmail.com All payments are expected within 7 days after the last winning auction is closed. Shipment 1. We will ship the item within 48 hours after receiving your payment, please kindly leave your detail shipping address and telephone number on ebay and paypal, both are very important for the shipment, thank you. 2. Usually we will ship by EMS or UPS or TNT ,that's depends on your country.Usually it will take 7 working days to arrive at your country.If you have special requirements about the shipping company, please contact me immediately after your payment, leave the note in both ebay and paypal, thank you. 3. We will upload the tracking number after shippment, you can search from both ebay and paypal. You can track online. 4. If you haven't received the item after 2 weeks of your payment, please contact me immediately! Email/MSN:contecmandy@hotmail.com Contact Contact Person :Mandy Email: contecmandy@hotmail.com Tel: 86-335-8015528(CN) Cell phone: 86-15032312869(CN) Contec Medical Systems Co.,Ltd, Manufacturer, Qinhuangdao,China Address: No.24 Huanghe West Road, Qinhuangdao Economic and Technical Development Zone, Hebei Province, China Terms Of Sale 1. All items are brand new, with 2 years warranty. 2. Client is responsible for the custom clearance and custom duty. If any, we will not be responisble for the customs clearance and duty, if you have special requirements for the declaration for your customs office, please contact us before your payment. 3. Customer is responsible for the returning shipping fee and we will send the replacement after receiving the returned item. 4. Your positive feedback will be appreciated very much, and in any case, please do contact us before leaving nagative feedback or ship the item back, we promise we will give you a satisfied answer. Buy Safe Product The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item. Certifications From CONTEC Medical systems: CE & ISO certification FDA K Number ?Pulse Oximeter Premarket Submission Number(510K): K073454 Listing Number: D045684 ?Pulse Oximeter Premarket Submission Number(510K): K082641 Listing Number: D064765 ?Pocket Fetal Doppler Premarket Submission Number(510K): K082480 Listing Number: D072247 ? Pulse Oximeter Premarket Submission Number(510K): K090671 Listing Number:D078664, ? ECG machine Premarket Submission Number(510K): K090936 Listing Number: D081157 If you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA's Center for Devices and Radiological Health. Add me to your Favorites list Visit my ebay store:chinamedicalshop My store: About us Contec Medical Systems focusing on research,manufacture and distribution of medical instruments,was founded in 1992 as a high tech company. At present we have 33 branch offices in China and more than 1500 employees. Our product line covers a wide range of 13 categories. Thousands of domestic hospitals are our customers. We have passed ISO 9000 and some of our products have got CE certificate. Contec hopes to cooperate with international companies to supply more innovative design and advanced technology products at affordable prices. Agent in the world! We are looking for partners in the world now! Do you want to become our agent in your country? Join us!
By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.