50lb Pound Refrigerant Recovery Tank With Double Valve & Collar Design Reusable

US $99.25

  • Lithia Springs, Georgia, United States
  • Jul 10th
  Description:   The 50 pound refrigerant recovery cylinder tank used steel make bottle body and HP295 material for dual valves, powder coated for high gloss and a durable finish.It Vapor with 1/2 inch ACME adapter and Collar design is easy to operate. Besides,it constructed with a Y-valve for liquid and vapor, 3/4” NPT opening accepts 80% fill with a float switch shut- off device. The refrigeration storage tank is filled with nitrogen during transportation to prevent moisture pollution.All of our Refrigerant recovery tank is Y valves and with standard certified. Welcome to Buy From Us!   50LB Pound Refrigerant Recovery Tank With Double Valve & Collar Design Reusable   Description:   The 50 pound refrigerant recovery cylinder tank used steel make bottle body and HP295 material for dual valves, powder coated for high gloss and a durable finish.It Vapor with 1/2 inch ACME adapter and Collar design is easy to operate. Besides,it constructed with a Y-valve for liquid and vapor, 3/4” NPT opening accepts 80% fill with a float switch shut- off device. The refrigeration storage tank is filled with nitrogen during transportation to prevent moisture pollution.All of our Refrigerant recovery tank is Y valves and with standard certified. Welcome to Buy From Us!   Feature:   Strong Material: The refrigerant recovery tank is made of steel and double valve HP325.This tank is filled with nitrogen to prevent water pollution during transportation. It must be emptied before use.   Application: This steel cylinder is a welded steel cylinder used for refilling refrigerant, which is widely used in refrigeration and air-conditioning equipment.   Advanced certification: Products are manufactured, tested, and accepted in strict accordance with DOT-4BA400 specifications and ARI standards. The production of products is subject to the supervision and management of the quality and technical supervision department.   Storage and placement: The refrigerant in the cylinder coexists in both gas and liquid phases at room temperature. The collar design makes it easy to pick up and move with both hands. When liquid phase refrigerant is needed, turn the cylinder upside down, connect the external pipeline, and then open the bottle.   Notice:  The Refrigerant Tank have professional servers and high quality that to prevent Personal injury a equipment damage,do not mix Refrigerant,this tank must be in an upright position ,read and follow instructions and warning in the operating.   Specification:    Connector: 1/4'' FL-M (7/16-20)  Dimensions (width x height): 12.25'' x 18.78''  Bottle weight: 28.71LB  Certification standard: DOT-4BA400  Rated capacity: >47.7LB / 21.6L  Rated working pressure: 400PSI / 2.7 MPa  Test pressure: 800PSI / 5.5 MPa  Safety valve pressure: 600PSI / 4.1 MPa  Tank material: HP325  Color: yellow / gray       Package Content:   1 x Refrigerant Recovery Reclaim 50lb Cylinder Tank     Note:   Strictly control the use and storage environment temperature (-20~55degrees), do not exceed it, and prohibit sun exposure and close to heat source.     Item Specifics UPC Does not apply Brand hitoptools Type Twin Refrigerant Recovery Machine Refrigerant R-401a R22 Connector 1/4'' FL-M (7/16-20) Dimensions 12.25'' x 18.78'' MPN 167287hit Bottle weight 28.71LB Certification standard DOT-4BA400 Rated capacity >47.7LB / 21.6L Rated working pressure 400PSI / 2.7 MPa Test pressure 800PSI / 5.5 MPa Country/Region of Manufacture China Safety valve pressure 600PSI / 4.1 MPa Custom Bundle No Tank material HP345 Color yellow / gray Payment 1.We accept PayPal onlypayment system supports Mastercard, Visa, Discover, American Express and eCheck(Echeck via Paypal will be pending until it is cleared). 2. You should pay your order within 10 days of the success of a transaction. If you do not pay the order in the meantime, we will cancel the transaction and resell the product to other buyers. In addition, it will appear as an Unpaid case from eBay. Shipping 1.We only ship to the 48 states excluding FPO or APO addresses. 2.Once your payment is completed, pls inform us by Email or leave ebay note if the changes are needed before we send the product. It is beyond our ability to change the address after we ship your item. Returns We ONLY accept returns with original package and will require a picture of the damaged part for verification.. Please make sure that item has NO man-made sabotage. Used items will not be accepted for return. Contact Us we are always listening to the customers and colleagues to keep innovating our products and service. Please feel free tocontact us if you have any idea or question regarding our products or service. DESCRIPTION PAYMENT SHIPPING RETURN POLICY CONTACT US 50LB Pound Refrigerant Recovery Tank With Double Valve & Collar Design Reusable   Description:   The 50 pound refrigerant recovery cylinder tank used steel make bottle body and HP295 material for dual valves, powder coated for high gloss and a durable finish.It Vapor with 1/2 inch ACME adapter and Collar design is easy to operate. Besides,it constructed with a Y-valve for liquid and vapor, 3/4” NPT opening accepts 80% fill with a float switch shut- off device. The refrigeration storage tank is filled with nitrogen during transportation to prevent moisture pollution.All of our Refrigerant recovery tank is Y valves and with standard certified. Welcome to Buy From Us!   Feature:   Strong Material: The refrigerant recovery tank is made of steel and double valve HP325.This tank is filled with nitrogen to prevent water pollution during transportation. It must be emptied before use.   Application: This steel cylinder is a welded steel cylinder used for refilling refrigerant, which is widely used in refrigeration and air-conditioning equipment.   Advanced certification: Products are manufactured, tested, and accepted in strict accordance with DOT-4BA400 specifications and ARI standards. The production of products is subject to the supervision and management of the quality and technical supervision department.   Storage and placement: The refrigerant in the cylinder coexists in both gas and liquid phases at room temperature. The collar design makes it easy to pick up and move with both hands. When liquid phase refrigerant is needed, turn the cylinder upside down, connect the external pipeline, and then open the bottle.   Notice:  The Refrigerant Tank have professional servers and high quality that to prevent Personal injury a equipment damage,do not mix Refrigerant,this tank must be in an upright position ,read and follow instructions and warning in the operating.   Specification:    Connector: 1/4'' FL-M (7/16-20)  Dimensions (width x height): 12.25'' x 18.78''  Bottle weight: 28.71LB  Certification standard: DOT-4BA400  Rated capacity: >47.7LB / 21.6L  Rated working pressure: 400PSI / 2.7 MPa  Test pressure: 800PSI / 5.5 MPa  Safety valve pressure: 600PSI / 4.1 MPa  Tank material: HP325  Color: yellow / gray       Package Content:   1 x Refrigerant Recovery Reclaim 50lb Cylinder Tank     Note:   Strictly control the use and storage environment temperature (-20~55degrees), do not exceed it, and prohibit sun exposure and close to heat source.     Item Specifics Brand : hitoptools Type : Twin Refrigerant Recovery Machine Refrigerant : R-401a R22 Connector : 1/4'' FL-M (7/16-20) Dimensions : 12.25'' x 18.78'' MPN : 167287hit Bottle weight : 28.71LB Certification standard : DOT-4BA400 Rated capacity : >47.7LB / 21.6L Rated working pressure : 400PSI / 2.7 MPa Test pressure : 800PSI / 5.5 MPa Country/Region of Manufacture : China Safety valve pressure : 600PSI / 4.1 MPa Custom Bundle : No Tank material : HP345 Color : yellow / gray Payment 1.We accept PayPal onlypayment system supports Mastercard, Visa, Discover, American Express and eCheck(Echeck via Paypal will be pending until it is cleared). 2. You should pay your order within 10 days of the success of a transaction. If you do not pay the order in the meantime, we will cancel the transaction and resell the product to other buyers. In addition, it will appear as an Unpaid case from eBay. Shipping 1.We only ship to the 48 states excluding FPO or APO addresses. 2.Once your payment is completed, pls inform us by Email or leave ebay note if the changes are needed before we send the product. It is beyond our ability to change the address after we ship your item. Returns We ONLY accept returns with original package and will require a picture of the damagd part for verification.. Please make sure that item has NO man-made sabotage. Used items will not be accepted for return. Contact Us we are always listening to the customers and colleagues to keep innovating our products and service. Please feel free to contact us if you have any idea or question regarding our products or service. All rights reserved.
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
UPC Does not apply
Rated capacity >47.7LB / 21.6L
Brand hitoptools
Rated working pressure 400PSI / 2.7 MPa
Type Twin Refrigerant Recovery Machine
Test pressure 800PSI / 5.5 MPa
Refrigerant R-401a R22
Country/Region of Manufacture China
Connector 1/4'' FL-M (7/16-20)
Safety valve pressure 600PSI / 4.1 MPa
Dimensions 12.25'' x 18.78''
Custom Bundle No
MPN 167287hit
Tank material HP345
Bottle weight 28.71LB
Color yellow / gray
Certification standard DOT-4BA400

Directions

Similar products from Recovery Machines & Units

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies