7-inch Oled Tft Vital Sign Monitor Patient Monitor Ecg, Nibp, Spo2, Resp Pr

US $680.00

  • Beijing, China
  • Jan 30th
7-inch 4-Parameter Vital Sign Monitor Patient Monitor   4 Standard parameters :ECG, NIBP, SpO2, RESP Model:8000A     Features:     Ergonomic design, portable, convenient for use 7" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters Unique digital SPO2 technology can work accurate during motion and low perfusion Anti AC & high-frequency electrosurgical & defibrillator’s interference Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation Audible & visual alarm available, adjustable Patient information management function Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room Optional software upgrading based on USB Wired/wireless networking with central monitoring system, up to 64 beds in one group Built-in 3 trace thermal recorder for printing real-time and historical data Multi-language i.e. English, Spanish, Turkish. Super long life rechargeable Lithium battery upto 4 hours of working time Suitable for adult, pediatrics and neonate patients       Standard configuration:              ECG, NIBP, SPO2, RESP, PR, Rechargeable Lithium battery   Optional:             ETCO2 (side stream)  Thermal recorder Wall mount Trolley Specification:       ECG Full lead: I, II, III, AVL, AVR, AVF and V Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s Band width: 0.05Hz-100Hz(3dB) Heart rate:  Scope: 15 times/minute to 300 times/minutes Accuracy:  ±1 time/minute Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.  Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.    Accuracy: Error rate < 20%          Undetected rate < 20%  ST section  Scope:     ±0.8mV Precision :  < ±0.05mV   SpO2 Detection scope:   0%-100% Accuracy         ±1%     90%-100%                                 ±2%      70%-89%    NIBP  Theory Electric oscillator  Cuff gassing time   less than 15 seconds First-time gassing pressure: dynamic state 24kPa(180 mmHg) Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg) 18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg), Automatic detection period: 1 minute to 240 minutes  Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m in -90min) and 30min(90 min -240min) Detection scope:  Systolic blood pressure:   4kPa -34kPa(30mmHg -255mmHg) Diastolic pressure             2kPa -29.3kPa(15mmHg -220mmHg) Mean pressure               2.7kPa~31.3kPa       (20mmHg~235mmHg) Detection accuracy  Static pressure: ±3mmHg Pulse rate:  ±2%   Resp Chest impedance method or concentration of carbon dioxide at end of respiration  Scope of chest impedance method     0 time/minute – 100 minutes/minute  Precision of chest impedance method  time/minute  Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby) Detection precision of respiration rate: ±1 time/minute  Statement: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so,  bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.All of our products are CE approved. Please kindly check the copy of the certificate in the listing below.  On Dec-09-14 at 01:05:25 PST, seller added the following information:
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand Yonker
Screen Size 7-inch
Model YK-8000A
Display Type TFT display
Country/Region of Manufacture China
Power supply Rechargeable Lithium battery
Parameter ECG, NIBP, SpO2, RESP
Battery Included Yes
Weight 6KG

Directions

Similar products from Health Condition Monitors

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies