7inch 5 Parameter Vital Sign Icu Ccu Patient Monitor Ecg/ekg,nibp,spo2,resp,pr

US $636.00

  • Beijing, China
  • Jan 30th
Description: Features for Patient Monitor:   Ergonomic design, portable, convenient for use 7" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters Unique digital SPO2 technology can work accurate during motion and low perfusion Anti AC & high-frequency electrosurgical & defibrillator’s interference Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation Audible & visual alarm available, adjustable Patient information management function Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room Optional software upgrading based on USB Wired/wireless networking with central monitoring system, up to 64 beds in one group Built-in 3 trace thermal recorder for printing real-time and historical data Multi-language i.e. English, Spanish, Turkish. Super long life rechargeable Lithium battery upto 4 hours of working time Suitable for adult, pediatrics and neonate patients  Standard configuration:             ECG, NIBP, SPO2, RESP, PR, Rechargeable Lithium battery  Optional:   ETCO2 (side stream)  Thermal recorder Wall mount Trolley Specification for Patient Monitor:      ECG Full lead: I, II, III, AVL, AVR, AVF and V Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s Band width: 0.05Hz-100Hz(3dB) Heart rate:  Scope: 15 times/minute to 300 times/minutes Accuracy:  ±1 time/minute Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.  Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.    Accuracy: Error rate < 20%          Undetected rate < 20%  ST section  Scope:     ±0.8mV Precision :  < ±0.05mV   SpO2 Detection scope:   0%-100% Accuracy         ±1%     90%-100%                                 ±2%      70%-89%    NIBP  Theory Electric oscillator  Cuff gassing time   less than 15 seconds First-time gassing pressure: dynamic state 24kPa(180 mmHg) Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg) 18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg), Automatic detection period: 1 minute to 240 minutes  Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m in -90min) and 30min(90 min -240min) Detection scope:  Systolic blood pressure:   4kPa -34kPa(30mmHg -255mmHg) Diastolic pressure             2kPa -29.3kPa(15mmHg -220mmHg) Mean pressure               2.7kPa~31.3kPa       (20mmHg~235mmHg) Detection accuracy  Static pressure: ±3mmHg Pulse rate:  ±2%   Resp Chest impedance method or concentration of carbon dioxide at end of respiration  Scope of chest impedance method     0 time/minute – 100 minutes/minute  Precision of chest impedance method  time/minute  Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby) Detection precision of respiration rate: ±1 time/minute         
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Model RPM-8000A

Directions

Similar products from Health Condition Monitors

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies