Ab Allen Bradley 1305 Ba04a Series A 2 Hp Micro Drive Vfd

US $795.00

  • South Richmond Hill, New York, United States
  • Jan 29th
Brand new and unused Allen Bradley 1305 2HP Inverter 1. Motor Full Load Amps (FLA) should not exceed the drive output current rating. 2. If the [PWM Frequency] is set above 4kHz, the output current must be derated per the chart on page 5- 20. When operating the drive in an ambient temperature at or near the maximum operating temperature (50 ° C), the following derating guidelines are recommended to guard against overheating depending on application and operating conditions. 3. Output current value listed for 200V input voltage. At 230V input voltage, output current is 9.6A for 3 phase and 6.8A for single phase. 4. Output current value listed for 380V input voltage. At 415V input voltage, output current is 5.3A. At 460V input voltage, output current is 4.8A. 5. Output current value listed for 380V input voltage. At 415V input voltage, output current is 8.4A. At 460V input voltage, output current is 7.6A. * For derating guidelines at ambient temperatures between 40 ° C and 50 ° C, consult Allen- Bradley. Control Inputs Programmable Output 1 Form A Relay Contact: Resistive Rating 115V AC/ 30V DC, 5A; Inductive Rating 115V AC/ 30V DC, 2A Programmable Output 2 Open Collector (Sink): 24V DC, +/- 20%, 50 mA maximum (User supplied source voltage) Analog Output (0 to 10V DC) Load lmpedance >= 4,000 Ohms, 8 bit resolution PWM AIgorithm Sine Weighted PWM Output Switching Device 3- Phase Output IGBT Intelligent Power Module V/ Hz Ratio Programmable Carrier Frequency Adjustable in 100Hz Increments from 2 kHz to 8 kHz. Output Current Derating applies above 4 kHz. DC Boost Adjustable single point or full custom - Start and Run boost available CONTROL FEATURES Current Limiting Trip Free Operation, Co- ordinated for Drive and Motor Protection Programmable from 20% to 150% of Drive Rated Current Overload 200%, Fixed by hardware, based on drive rating 150% for 60 seconds Motor Protection (1) Electronic Overload Protection. Adjustable from 20% to 115% (Motor FLA) Overload Pattern #0 Flat response over speed range (no current derating) Overload Pattern #1 Current derating below 25% of Base Speed Overload Pattern #2 Current derating below 50% of Base Speed Accel/ Decel Time(s) 0.1 to 3600 Seconds, independently set (2 Accel, 2 Decel) Preset Speeds 0 to 400 Hz, 7 selections, independently set Jog Input 0 to 400 Hz Stopping Modes 4 modes programmable Ramp to stop 0.1 to 3600 seconds Coast Stops all PWM Output DC Brake to stop Applies DC Voltage to the Motor for 0 to 150 seconds. Has nothing to do with dynamic braking or external brake operation. S- Curve Ramps to stop with S- Curve profile Protective Features Excessive Temperature Embedded temperature sensor trips if factory preset level is exceeded (2) Over/ Under Voltage DC Bus voltage is monitored Power Ride Through Minimum ride through 15mS under nominal conditions Control Ride Through Minimum ride through is 0.5 Seconds - typical value 2 seconds Ground Short Any output short to ground, detected prior to start Line Voltage Transients Inherent MOV (varistor) protection Output Short Circuit Inherent short circuit protection provided within IPM 1. See Page 5- 12 for NEC and UL information. 2. Conditions such ambient temperature, overload, duty cycle, etc. can affect tripping time. PROGRAMMING/ COMMUNICATIONS Adapters The maximum current draw of all adapters connected to the drive should not exceed 250 mA Hand Held Programming Optional Human Interface Module (HIM can be removed from the Drive) Type of Annunciation Parameters displayed in textual form, organized in Iogical groupings Type of Display 16 character, 2 line LCD supertwist with backlight Language Capability Multiple Languages available Local Controls 3 versions available ( Digital Pot., Analog Pot. and Blank) Communication Adapters Optional adapters provide Remote I/ 0, or RS232/ RS422/ RS485/ DF1/ DH485, or DeviceNet? capability. MONITORING Output Frequency (Hz) Displayed over the entire range of operation with direction indication Output Voltage (V) Selectable as a displayed parameter Output Current (A) Selectable as a displayed parameter in % or actual value Output Power (kW) Selectable as a displayed parameter in % or actual value DC Bus Voltage (V) Selectable as a displayed parameter Frequency Command (Hz) Selectable as a displayed parameter Process Parameter Any drive variable can be scaled and definable text can be added up to 8 characters Drive Temperature `C Selectable as a displayed parameter Last Fault The previous 4 faults can be displayed for troubleshooting

Directions

Similar products from AC Motor Speed Control Systems

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies