Agilent / Hp 53230a Universal Frequency Counter/timer: 350 Mhz, 12 Digits, 20 Ps

US $4,625.00

  • Oceanside, California, United States
  • Jan 29th
AGILENT 53230A COUNTER / TIMER *Call (760) 806-6600 to RENT this item* DESCRIPTION   Frequency counters are depended on in research and development and also in manufacturing for the fastest, most accurate frequency and time interval measurements. The Agilent / HP 53230A Universal Frequency Counter/Timer expands on this expectation to provide you with the most information, connectivity and new measurement capabilities, while continuing to build on, already reliable, speed and accuracy. Features and Specifications of the Agilent / HP 53230A Universal Frequency Counter/Timer include: Two 350 MHz input channels, plus optional third channel (6 GHz or 15 GHz) 12 digits/second resolution, 20 psec time interval resolution Built-in math analysis and color, graphical display (trend and histogram) Continuous, gap-free measurements and timestamps for basic modulation domain analysis LXI-C/LAN and USB standard, GPIB optional Optional: Lithium Ion Battery Input Characteristics: Channels 1 & 2:  Standard, DC - 350 MHz Standard Inputs: Frequency Range: DC coupled:  DC (1 mHz) to 350 MHz (2.8 ns - 1000 sec) AC coupled 50 O or 1 MO:  10 Hz - 350 MHz Input: Connector: Front panel BNC(f) Input Impedance (typ):  Selectable 1 M O A± 1.5% or 50 O A± 1.5% || <25 pF Input Coupling:  Selectable DC or AC Input Filter:  Selectable 100 kHz cut-off frequency low pass 10 Hz (AC coupling) cut-off frequency high pass filter Amplitude Range: Input Range:  A±5 V (A±50 V) full scale ranges Sensitivity (typ):  DC - 100 MHz: 20 mVpk > 100 MHz: 40 mVpk Noise:  500 AµVrms (max), 350 AµVrms (typ) Input Event Thresholds: Threshold Levels:  A±5 V (A±50 V) in 2.5 mV (25 mV) steps Noise Reject:  Selectable On/ Off Slope:  Selectable Positive or Negative Auto-scale: Acquires signal for current measurement channel, selects range (5 V or 50 V), sets auto-level 50% Auto-level:  Selectable On or Off: On:  Sets auto-level (% of Vpp) operation Occurs once for each INIT or after a timeout Measures signal Vpp and sets Trigger level to 50% Off:  Selectable user set level (Volts) Minimum Signal Frequency for Auto Level:  User selectable:  Slow:  50 Hz;  Fast:  10 kHz Minimum Signal for Auto Level:  300 mVpp Maximum Input: 50 O damage level:  1 W 50 O protection threshold:  Will not activate below 7.5 VpK 50 O internal termination auto-protects by switching to 1 M O 1 M O damage level:  DC - 5 kHz:  350 Vpk (AC + DC) 5 kHz - 100 kHz:  Derate linearly to 10 Vpk (AC + DC)  >100 kHz:  10 Vpk (AC + DC) General Characteristics: Warm-up Time:  45 minutes Dislay:  4.3" Color TFT WQVGA (480 x 272), LED backlight USB flash drive:  FAT, FAT32 Programming language: SCPI:  532xx Series and 53131A/53132A/53181A Series compatibility mode Programming interface: LXI-C 1.3:  10/ 100/ 1000 LAN (LAN Sockets and VXI-11 protocol) USB 2.0 device port:  USB2.0 (USB-TMC488 protocol) GPIB interface (Option 400):  GPIB (IEEE-488.1, IEEE-488.2 protocol) Web user interface:  LXI Class C Compatible Notes / Included Options 010 - Ultra High-stability OCXO Timebase 106 - Add Channel 3 - 6 GHz CW 150 - Pulse Microwave Measurements 400 - Add GPIB Interface *All of our equipment has been tested.  Additional Calibration may be available upon request!  ~Items sold with shown accessories, a power cord and manual on CD (when available)~ WARRANTY, PAYMENT, AND SHIPPING TERMS Warranty Info & Return Policy We strive to exceed our customer's expectations and maintain 100% Positive Feedback.  And although we do not use eBay's automated Return Policy, all goods or equipment sold by AxiomTest include a 30-Day Warranty which starts the day the equipment is shipped. So contact us immediately if there is a discrepancy with your order or an equipment malfunction so we can issue a repair, replacement, or refund. All orders also come with a limited 5-day ROR (Right of Return).  This ROR is limited to goods found to be non-acceptable due to cosmetic defect (not previously disclosed) or an item not meeting manufacturer's spec as advertised. ROR does not apply to wrong item(s) ordered by customer, equipment that has been misused or damaged by customer's misuse (intentional or unintentional), or any orders damaged in transit. Returns must be shipped with all original packaging and accessories.  We will not accept any items with obvious signs of additional wear and tear or internal component alterations.  All of our items will ship with “Warranty Void” tamper resistant stickers. If any stickers have been removed or tampered with your refund will be canceled. Please include your RMA # on the packing slip, way bill, or package. *CUSTOMER RESPONSIBLE FOR ANY AND ALL RETURN SHIPPING COSTS* Payment Options Domestic Buyers - PayPal, Wire Transfer, Money Order, Company, Bank, or Personal Check.  International Buyers: PayPal or Wire transfer only.  All funds must be in US Dollars. Unsecured funds must clear prior to shipment.  Wire Transfers subject to a $25 service fee. Shipping Unless noted otherwise, all shipments are done through FedEx. If you would like to utilize your own shipping account please notify us PRIOR to checkout.  Saturday and Residential delivery may be available at an additional third party charge depending on the shipping method you choose.  We offer shipping outside of the United States.  However, some international laws prohibit us from shipping certain items to certain countries.  Additionally, not all countries are supported by our service provider. You may also elect to use your own carrier, but we'll be responsible for providing the correct documentation and scheduling the pickup.  We are not set up to ship via USPS, and we will NOT falsify any import documents for international orders - no exceptions. Please note: In all sales where an item is prohibited to ship internationally to a successful buyer, that buyer will be notified of non-shipment and a full refund will be made. We reserve the right not to ship any item internationally that is controlled by the US Department of Commerce’s laws and regulations and deemed non-shippable to that region of the world or to listed individuals.   eBay's International Shipping calculations do not include any additional duties, fees, or VAT that may be associated with importing this item into a foreign country - please bid accordingly Sales Tax California residents will be charged sales tax if no resale or tax exempt form is submitted prior to payment. TRIED, TESTED...ACCEPTED.
Condition Used :
An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections.
Seller Notes Equipment has been tested and is fully functional with a 30-day Warranty

Directions

Similar products from Frequency Counters, Timers & Manual Clicker Counters

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies