Agilent Hp E4418b Epm Series Single Channel Power Meter

US $1,145.00

  • Toledo, Ohio, United States
  • Jun 9th
                                                              Content on this page requires a newer version of Adobe Flash Player.                      The Following Items Are Included: Agilent E4418B EPM Series Power Meter (BC# 21364) Ethernet Cable BNC Cable Power Cord RS232 PC Interface Cable User Manual On CD-ROM     BE SURE TO CHECK OUR EBAY STORE FOR OTHER ITEMS! This Item Has A Current Calibration!   Agilent E4418B EPM Series Power Meter   Please Note That This Sale Is For The E4418B Power Meter Only, No Power Sensors Are Included!   The E4418B power meter is designed for bench and automatic test equipment (ATE) use   Includes Accessories As Listed Above!     Working Condition: Excellent Condition: Refurbished Calibrated: Yes Warranty: 90 Day Exchange Warranty     Agilent E4418B EPM Series Power Meter The E4418B power meter is designed for bench and automatic test equipment (ATE) use. Features: Fast measurement speed (up to 200 readings per second, over the GPIB, with E-series sensors) Speed improvement of x2 using the 8480 series power sensor (compared to the 437B) No range-switching delays with 8480 series sensors, and only one fast-range switch point with E-series sensors Code compatibility with 437B and 436A power meters GPIB and RS232 connector for remote control of all functions Specifications: Compatible power sensors: E4410 and E9300 E-Series, 8480 Series and N8480 Series average power sensors Frequency range: 9 kHz to 110 GHz, sensor dependent Power range: –70 dBm to +44 dBm (100 pW to 25 W), sensor dependent Single sensor dynamic range: 90 dB maximum (E-Series sensors) 50 dB maximum (8480 Series sensors) 55 dB maximum (N8480 Series sensors) Display units: Absolute: Watts or dBm Relative: Percent or dB Display resolution: Selectable resolution of 1.0, 0.1, 0.01, and 0.001dB in Log mode, or 1 to 4 digits in linear mode Default resolution: 0.01 dB in log mode, 3 digits in linear mode Accuracy Absolute: ±0.02 dB (log) or ±0.5% (linear). Relative accuracy: ±0.04 dB (log) or ±1.0% (linear). Zero set (digital settability of zero): Sensor dependent. For E-Series sensors, this specification applies to a zero performed when the sensor input is not connected to the POWER REF. Zero drift of sensors: Sensor dependent Measurement noise: Sensor dependent Effects of averaging on noise: Averaging over 1 to 1024 readings is available for reducing noise. Use the noise multiplier, for the appropriate mode (normal or x2) and number of averages, to determine the total measurement noise value. Measurement noise calculation: (<45 pW x 2.75) = <121 pW Power reference Power output: 1.00 mW (0.0 dBm). Factory set to ±0.4% traceable to the National Physical Laboratory (NPL), UK1 . Accuracy: For two years: ±0.5% (23 ± 3 °C) ±0.6% (25 ± 10 °C) ±0.9% (0 to 55 °C) Frequency: 50 MHz nominal SWR: 1.06 maximum Connector type: Type-N (f), 50? Measurement speed Three measurement speed modes, over the GPIB, are available as shown, along with the typical maximum measurement speed for each mode. With E4418B power meter Normal: 20 readings/second x2: 40 readings/second Fast: 200 readings/second Power meter functions Accessed by key entry: either hardkeys, or softkey menu, and programmable. Zero: Zeros the meter. (Power reference calibrator is switched off during zeroing). Cal: Calibrates the meter using internal (power reference calibrator) or external source. Reference cal factor settable from 1% to 150%, in 0.1% increments. Frequency: Entered frequency range is used to interpolate the calibration factors table. Range: 1 kHz to 999.9 GHz, settable in 1-kHz steps. Cal factor: Sets the calibration factor for the meter. Range: 1% to 150%, in increments of 0.1%. Relative: Displays all successive measurements relative to the last displayed value. Offset: Allows power measurements to be offset by –100 dB to +100 dB, settable in 0.001-dB increments, to compensate for external loss or gain. Save/recall: Store up to 10 instrument states via the save/recall menu. dBm/W: Selectable units of either Watts or dBm in absolute power; or percent or dB for relative measurements. Filter (averaging): Selectable from 1 to 1024. Auto-averaging provides automatic noise compensation. Duty cycle: Duty cycle values between 0.001% to 99.999%, in increments of 0.001%, can be entered to display a peak power representation of measured power. The following equation is used to calculate the displayed peak power value: peak power = measured power/duty cycle. Sensor cal tables: Selects cal factor versus frequency tables corresponding to specified sensors (8480 Series only). Limits: High and low limits can be set in the range –150 dBm to +230 dBm, in 0.001-dBm increments. Preset default values: dBm mode, rel off, power reference off, duty cycle off, offset off, frequency 50 MHz, AUTO average, free run, AUTO range (for ESeries and N8480 Series sensors). Display: Selectable single and split screen formats are available. Aquasianalog display is available for peaking measurements. The dual-channel power meter can simultaneously display any two configurations of A, B, A/B, B/A, A-B, B-A and relative. General specifications Dimensions The following dimensions exclude front and rear protrusions: 212.6 mm W x 88.5 mm H x 348.3 mm D (8.5 in x 3.5 in x 13.7 in) Weight 4.0 kg (8.8 lb) net, 7.9 kg (17.4 lb) shipping Recorder outputs: Analog 0 to 1-Volt, 1-k output impedance, BNC connector. E4419B recorder outputs are dedicated to channel A and channel B. Remote input/output: A TTL logic level is output when the measurement exceeds a predetermined limit. TTL inputs are provided to initiate zero and calibration cycles. RJ-45 series shielded modular jack assembly connector. TTL Output: high = 4.8 V max; low = 0.2 V max TTL Input: high = 3.5 V min, 5 V max; low = 1 V max, –0.3 V min. GPIB: Allows communication with an external controller RS-232/422: Allows communication with an external RS-232/422 controller. Male/plug 9 position D-subminiature connector Ground: Binding post, accepts 4-mm plug or bare-wire connection. Input voltage range: 85 to 264 VAC, automatic selection. Input frequency range: 50 to 440 Hz Power requirement: Approximately 50 VA (14 W) Environmental characteristics General conditions: Complies with the requirements of the EMC Directive 89/336/EEC. This includes Generic Immunity Standard EN 50082-1: 1992 and Radiated Interference Standard EN 55011: 1991/CISPR11:1990, Group 1 - Class A. Temperature: 0°C to 55 °C Maximum humidity: 95% at 40 °C (non-condensing). Minimum humidity: 15% at 40 °C (non-condensing). Maximum altitude: 3000 meters (9840 feet). Storage temperature: –20 °C to +70 °C. Non-operating maximum humidity: 90% at 65 °C (non-condensing) Non-operating maximum altitude: 15240 meters (50,000 feet) Conforms to the following product safety specifications: EN61010-1: 1993/IEC 1010-1: 1990 +A1/CSA C22.2 No. 1010-1: 1993 EN60825-1: 1994/IEC 825-1: 1993 Class 1 Low Voltage Directive 72/23/EEC Remote programming Interface: GBIB interface operates to IEEE 488.2. RS-232 and RS-422 serial interface supplied as standard Command language: SCPI standard interface commands. 436A and 437B code compatible (E4418B only GPIB compatibility: SH1, AH1, T6, TE0, L4, LE0, SR1, RL1, PP1, DC1, DT1, C0. Battery: Lithium polycarbon monoflouride, approximate lifetime 5 years at 25 °C   Please check our Huge Inventory with savings of up to 80% off of retail on Cat5/5e/6 LAN Cable Certifiers and Fiber Optic OTDR's, Fusion Splicers, CATV Meters, Fiber Optic Kits, Sources, Meters, Tools, Network Analyzers and much more. Here is a Link to our Ebay Test Equipment Store. All of our Test Equipment is backed with a Full Warranty and unbeatable customer support & service. Please don't hesitate to contact us for a Quote on Something you don't see in our inventory, sometimes we have items that may have not been listed or processed yet.   Test Equipment Store Offers a wide range of Refurbished Telecom/ Datacom Tools and Test Measurement Equipment. Which includes Fiber Optic Test and Splicing tools, Fusion Splicers, OTDRs, Copper and Fiber Cable Certifiers, CATV Test Equipment, Cable and Antenna Analyzers, Network Analyzers and much more!   We carry a large inventory of quality refurbished and used test equipment from all the major manufacturers. If you are looking for multiple quantities or if we don't have a listing for a particular item that you are looking for. Please contact us as it may be fresh inventory waiting to be listed or we'll be glad to find it for you at the best price possible and put up an eBay listing for you!   Contact: Test Equipment Store eBay Sales Phone: 1-419-517-6681 Toll Free : 1-800-548-2381     We Ship World Wide!   We will attempt to ship your item(s) within 24 hours after payment has been received. To get a real-time shipping quote to your destination, enter your country and zip / postal code information into the shipping calculator and click "Get Rate". Many countries impose their own customs, duties, tariffs, taxes, etc. on items being shipped from a foreign country. We do not cover those cost's and we recommend that you contact your countries customs agency for that information. We Offer Multiple Quantity Price & Shipping Discounts, Email Us If You Are Interested In Larger Quantities.   UPS Ground   United States   USD 0.00 USPS Express Mail International (EMS)   Worldwide   USD 0.00   We accept credit card payment transactions via the online checkout system! The checkout process is designed so that it communicates with the merchant to confirm that payment has been made and cleared. Other methods of payment are outlined through the online checkout process. Winning bidders must contact us within 3 days after auction close if special payment arrangements are needed. Your payment is expected within 5 days after the auction close. Unpaid auctions will be forfeited after 5 days of the auction close and the Item(s) will be relisted for sale. Items will be shipped within 24 hours (1 Business Day) upon receipt of payment from the winning bidder. (Certain orders may take longer for processing due to comprehensive final service inspections) A Shipment Tracking number(s) will be provided to inform Buyers of their expected ETA (Estimated Time of Arrival). Tracking number(s) will be provided the same day as order shipment. Thank you ALL MAJOR CREDIT CARDS & PayPal ACCEPTED               Powers Your Online Marketplace Make inventory management a breeze with Kyozou eBay Inventory Management Software
Condition:
Seller refurbished: An item that has been restored to working order by the eBay seller or a third party not approved by the manufacturer. This means the item has been inspected, cleaned, and repaired to full working order and is in excellent condition. This item may or may not be in original packaging. See the seller’s listing for full details. ...
Brand Agilent
Model E4418B

Directions

Similar products from Plug Energy Meters and Power Meters

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies