Anritsu Ms9740a Optical Spectrum Analyzer Osa - Range 600 To 1750 Nm Calibrated

US $8500

  • Gatineau, Quebec, Canada
  • Jun 20th
Anritsu MS9740A OSA Calibration included * Buy it Now * The Anritsu MS9740A is a diffraction-grating optical spectrum analyzer for analyzing optical spectra in the wavelength band 600 to 1750 nm. The MS9740A is the fourth generation of the MS9710 series from Anritsu. The MS9740A has numerous pre programmed measurement functions and can be equipped with options such as internal calibration source. The input is fibered (not air). Specifications - Wavelength Range: 600 to 1750 nm - Dynamic Range: 70 dB (1 nm from peak wavelength) - Wavelength Accuracy: ±300 pm (600 to 1520nm) - Wavelength Linearity: ±20 pm (1520 to 1620 nm) - Polarization Dependency: ±0.05 dB (1550/1600 nm) Additional Information - Resolution Accuracy: ±2.2% (1520 to 1620 nm, resolution: 0.5 nm) - Level Accuracy: ±0.4 dB (1310/1550 nm, input: -10 dBm, resolution: >0.1 nm) - Level Linearity: ±0.05 dB (1550 nm, –30 to 20 dBm, optical ATT: off)  The MS9740A is an Optical Spectrum Analyzer for a wide range of applications including light source evaluation, measurement of loss wavelength characteristics in optical devices and waveform analysis of WDM Systems. Contact us  for more information and for a shipping quote. The AssetRelay difference? Our Laboratory! TESTING SERVICES AVAILABLE: Included Basic Calibration  : This calibration is performed to ensure the functionality of the equipment and to verify that the "key features" meet the manufacturer's published specifications, wherever possible, at the points tested. The "key features" are the most important parameters of the equipment (i.e. for an attenuator the "key feature" is the attenuation accuracy). This calibration will assure confidence in the equipment; it comes with calibration label and a certificate of calibration. Optional ($) Premium Calibration: This calibration is performed using manufacturer's performance tests procedure, where available. It is designed to assure that the equipment meets or exceeds manufacturer's published specifications. Since we have extended knowledge and experience within the fiber optics field, in many instances our procedures surpass the manufacturer's calibration procedures (i.e. given that we have a lot of repair experience with these types of equipment, we perform additional tests that are not verified by the manufacturer's procedures and that we consider as very important.). Instrumentation used during this calibration is traceable to N.I.S.T. (National Institute of Standards and Technology) or C.N.R.C. (Canadian National Research Council). The equipment would be shipped with a calibration label, a certificate of premium calibration and calibration data. We only ship working units in perfect condition. This MS9740A will be packaged using our 'box in a box' system Seller's Payment Instructions All orders are prepaid.  Wire transfer is our preferred method of payment. Add $ 20.00 USD for wire transfer fees. Instructions included with our quotes and invoices.  Payment must be received in full prior to being shipped out unless otherwise noted.  International shipment buyers assume all responsibilities for customs, duties & taxes as additional fees which ARE NOT included and/or associated within the sales price. Shipping Details Buyer to pay all shipping costs.  International shipping will be via Fed Ex. Shipping on your carrier account, contact us before bidding for quote on shipping. You need to email us to get a quote on shipping and handling Contact us Asset Relay's logistics team will also assist you with any documentation required to have your order cleared through customs. Over the years, we've learned that specific documents are required for each country so orders can clear customs swiftly. Our logistics employees will help make the import and export of products as easy as possible for you. Sending the right documents with precise information along with your order will guarantee that you receive the goods promptly and help prevent any additional costs or delays. Warranty Policy 30 Days WARRANTY Right of Return shall become null and void should it be determined that the equipment was subjected to undue abuse, involved in any type of mishap, incorrectly wired and/or used/maintained in a manner contrary to the manufacturer's published instructions  All products must be returned prepaid to our lab in accordance with the return instructions. Questions? We are here to answers them! Please call us if you need more information on equipment. We will do our best to answer any question you may have. If we can't answer you straight away over the phone we will take down your e-mail address so we can make the proper research on the unit(s) and get back to you as soon as we can. We can provide you with additional pictures, we can make physical checks on the unit since it is on site in our warehouse, and we can even send you a spec sheet if we have it on file! Contact us if you have any questions!

Directions

Similar products from Spectrum Analysis Systems

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies