Baxter 6301 Infusion Pump Iv Pump

US $110

  • West Chester, Pennsylvania, United States
  • Jan 30th
REFURBISHED LIKE NEW   Baxter 6301 infusion pump THIS UNIT IS REFURBISHED LIKE NEW IN GREAT COSMETIC CONDITION.  UNIT HAS BEEN CALIBRATED AND TESTED BY A BIOMEDICAL TECHNICIANS.  COMES WITH CERTIFICATION PAPERWORK  UNIT HAS CLEAR AND FREE TITLE WITH 100% SATISFACTION THAT THIS UNIT IS IN GREAT WORKING ORDER.  ANY QUESTION CALL BIOMEDIX MEDICAL 610 656 5851.  MULTIPLE UNITS AVAILABLE PLEASE CHECK OUT MY OTHER AUCTIONS. Baxter Travenol 6301 Infusion Pump Product Specifications Dimensions: 32.5 cm W x 13 cm D X 29 cm H (13 in W x 5.1 in D x 11.4 in H) Dimensions: 12.0" x 14.75" x 7.5" (30.5 cm x 37.5 cm x 19.1 cm) Weight: 8.1 Kg (17.9 lb) Battery: 12 volt, 2.0 ampere, sealed lead acid Battery Recharge: 80% charged within 8 hr. Battery Life: 6 hr at 1-1,400 mL/hr (4 hr with both channels operating at 1-1,400 mL/hr) Power Cord: Biomed replaceable 2.75 m (9 ft) Leakage Current: Less than 50 micro-amps (per UL 544) Fuse: .8 ampere, 250 volt, slow-blow Communications Port: RS232 serial port Operating Environment: 15.5-37.7?C (60-100?F) Power Requirements: 115 VAC, 60 HZ, 50 W Flow Rate Range: Primary program: 1.0-99.9 mL/hr in 0.1 mL increments or 1-1999 mL/hr in 1 mL increments.Upper limit can be reduced by authorized service personnel. Secondary program: 1.0-99.9 mL/hr in 0.1 mL increments or 1-999 mL/hr in 1 mL increments VTBI Range: 1.0-99.9 mL in 0.1 mL increments or 1-9999 mL in 1 mL increments for both primary and secondary. Upper limit can be reduced by authorized service personnel. Ramp PDP Parameter Ranges: Total VTBI: 100-9,999 in 1 mL increments. Upper limit can be reduced by authorized service personnel. Delay Time: 00:00 - 08:00 hours in minute increments. Run Time: 01:00 - 16:00 hours in minute increments. Ramp Up: 00:00 to 45% of the Run Time, in minute increments. Ramp Down: 00-00 to the Run Time minus Ramp Up, in minute Increments. Air-in-Line Detection: Factory set to NORM, which causes the pump to alarm on air bubbles approximately 75 uL or larger. The MIN setting causes the pump to alarm on air bubbles approximately 50 ul or larger.     BIOMEDIX MEDICAL INC 1153 NEWAR RD TOUGHKENAMON, PA 19374 610 656 5851 CHECK OUT MY OTHER AUCTIONS          "The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item." If you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA's Center for Devices and Radiological Health: Links:http://www.fda.gov/cdrh/devadvice/ or http://www.fda.gov/cdrh/industry/support/index.html Phone number: 800.638.2041 email: dsmica@cdrh.fda.gov  Thank you for your cooperation. Posted with eBay Mobile
Condition Seller refurbished :
An item that has been restored to working order by the eBay seller or a third party not approved by the manufacturer. This means the item has been inspected, cleaned, and repaired to full working order and is in excellent condition. This item may or may not be in original packaging. See the seller’s listing for full details.
Seller Notes units have been refurbished with new batteries installed

Directions

Similar products from Feeding & Infusion Pumps

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies