Boc Edwards 658 Barocel Pressure Transducer Capacitance Manometer 1 Torr

US $399.99

  • Phoenix, Arizona, United States
  • Feb 17th
Click Here. Double your traffic. Get Vendio Gallery - Now FREE! BOC Edwards 658 Barocel Pressure Sensor/Transducer Capacitance Manometer Comes with what you see in the pictures. If you don't see it, you probably wont get it. Specifications are from BOC Edwards and may vary slightly due to upgrades, options, or revisions this unit may or may not have. We do not have anyway to formally test this unit so we are selling it as-is. The Unit's Serial Number Tag Reads: Type: 658 TRANS. 1TR W/RT ANG BELLOWS Range: 1 TORR Serial Number: 7102772 Reorder Number: K658A009 Brief Description: The 658 manometer is ideal for use in vacuum systems where accuracy zero stability and resistance to process contamination are critical to successful operation. Only Inconel and Monel surfaces are exposed to the process gases and all welded joints are designed to permit rapid degassing. There is no loss of accuracy due to changes in gas composition or the presence of electrically conductive gases. Features and Benefits: Wide measuring range – full four decade measurement. High accuracy – 0.15% of reading. High resolution – better than 0.005% of FS. Temperature controlled – internal temperature maintained at 100°C; improved zero stability: better than 0.002% FS / °C. True total pressure – calibration and measurement independent of gas composition. High level dc output – 0 to 10 volts dc full scale, linear with pressure. Applications: Plasma Deposition/Etch Sputtering/PVD/RTP Industrial CVD/Ion Implantation LPCVD Crystal growing/freeze dryers Specifications: Pressure Range: 0 to 1 Torr Accuracy: 0.15% of reading + 0.005% of full scale Repeatability: ±0.01% of full scale Resolution: 0.005% of full scale Warm-up Time: 2 hours Control Temperature: 100°C Ambient Operating Temperature: 15 - 70°C Storage Temperature: -45 - 85°C Temperature Effect on Zero: < 0.005% of full scale/°C Ambient Condition Effect on Sensitivity:   Temperature: < 0.02% of reading/°C   Barometric Pressure: < 0.005% of full scale/760 torr   Relative Humidity (0 - 95% RH):
We do not have anyway to formally test this unit so we are selling it as-is.
Brand Edwards
MPN K658A009
Model 658

Directions

Similar products from Other Semiconductors & Printed Circuit Boards

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies