Cadd 5400 Infusion Pump Ambulatory Pump With Infusion Case

GBP 99.00

  • ROATH, Cardiff, United Kingdom
  • Mar 28th
CADD 5400 infusion pump Ambulatory pump with infusion case TESTED AND IN WORKING CONDITION The following tests were conducted:  - Flowrate/Volume Tests  - Occultation - battery alarms The accuracy of the fluid delivery in appeared to be within limits.  Product Specifications Pump Resolution: 50 microliters per interval Dimensions: 1.1? D x 3.5? W x 6.4? H including 50 ml reservoir Weight: 15 oz including battery and empty 50 ml reservoir Power Source: 9 volt alkaline or lithium battery Pump Timing Accuracy: A±0.1% System Delivery Accuracy: A±6% nominal Continuous Given Range: 0-999 ml in 1 ml increments rounded down to the nearest ml Continuous RES VOL Alarm Range: 0-1500 ml in 1 ml increments rounded up to the nearest ml Continuous ML/HR range: 0.00-75.0 ml/hr in 0.1 ml increments Intermittent ML range: 0.00-150.0 ml in 0.1 ml increments Intermittent Period Range: 10 min-12 hours, in 10 min increments Intermittent Cycle Range: 20 min-12 hours and 10 min (20:10), in 10 min increments; and 24 hours for a 24 hour cycle Intermittent KVO ml/hr Range: 0.2-10.0 ml/hr, in 0.1 ml increments Intermittent Delayed Start Range: 10 min-12 hours, in 10 min increments Intermittent Cycle Given Range: 0 min-12 hours and 10 min (12:10), in 1 min increments; and 0-24 hours in 1 hour increments when Cycle is programmed in 24 hour mode Intermittent Given Range: 0-999 ml in 1 ml increments rounded down to the nearest ml Intermittent RES VOL Alarm Range: 0-1500 ml in 1 ml increments rounded up to the nearest ml Pump Alarms: Low battery battery depleted Pump in Stop Mode controller, microprocessor, or motor fault improper delivery power up fault low residual volume high delivery pressure (22 A± 12 psi) works well, if you are not happy with the pump, you are welcome to return it, we will refund or replace it for you IF YOU ARE NOT SATISFIED WITH ITEM YOU ARE WELCOME TO RETURN IT, WE WILL REFUND OR REPLACE IT FOR YOU PAYMENT EXPECTED WITH IN 5 DAYS UK CUSTOMERS: I ACCEPT PAYPAL, UK CHEQUE / PO OVERSEAS CUSTOMERS: I ACCEPT PAYPAL / BANK TRANSFER POSTAGE AND PACKING COSTS: ?11.00 UK DELIVERY WITH ROYAL MAIL RECORDED DELIVERY & INSURANCE PLEASE EMAIL ME FOR OVERSEAS SHIPPING COSTS THANKS working condition, tested and works well, Any question Please do email us, IF YOU ARE NOT SATISFIED WITH ITEM YOU ARE WELCOME TO RETURN IT, WE WILL REFUND OR REPLACE IT FOR YOU PAYMENT EXPECTED WITH IN 5 DAYS UK CUSTOMERS: I ACCEPT PAYPAL, UK CHEQUE / PO OVERSEAS CUSTOMERS: I ACCEPT PAYPAL / BANK TRANSFER POSTAGE AND PACKING COSTS: FREE UK DELIVERY WITH ROYAL MAIL RECORDED DELIVERY & INSURANCE PLEASE EMAIL ME FOR OVERSEAS SHIPPING COSTS THANKS
Condition:
Used: An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections. ...
Brand CADD

Directions

Similar products from Feeding & Infusion Pumps

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies