Cefda 12.1'' Icu Patient Monitor Ecg Spo2 Nibp Pr Resp Temp Network Touch Screen

GBP 419.00

  • Beijing, China
  • Jan 30th
We are manufacturer: Contec Medical Systems  Touch Screen CMS7000 12.1'' ICU Patient Monitor,Multi parameters Patient MonitorModel:CMS7000 Plus Introduction: This equipment with touch screen can monitor such parameters as ECG, RESP, SpO2, NIBP, and Dual- channel TEMP. It integrates parameter measuring module, display and recorder in one device to form a compact and portable device. At the same time, its built-in replaceable battery provides convenience for patient moving. Features: * Elegant appearance, clear marks, standard interface, oxyCRG SCREEN, trend graph, big characters, other BED observation, which are convenient for user. * Be applicable for adult, pediatric and neonatal. * Standard parameters of ECG, RESP, NIBP, SpO2 and dual-channel TEMP. IBP, CO2, built-in printer, curving handle, moving bracket and hanging bracket are optional. * Finish all operations by touch screen or keys and knobs. * Operation interface with Chinese and English. (Optional languages: French, German, Italian, Dutch, Portuguese, Turkish, Spanish, Poland.) design with full built-in module, stable and reliable performance. *12.1'' color TFT LCD with high-resolution displays patient parameter and waveform, and alarm, bed NO, clock, state and other information provided by the monitor synchronously. * Monitoring contents, scan speed, volume and output contents can be set optionally. * Storage of 480-hour trend data, and review of 40-second holographic waveform. * Storage and review of 72-hour ECG waveform. * Function of NIBP review, storage for up to 2400 NIBP data. * Adopt digital SpO2 technology, which has strong anti-interference and anti-weak filling capability. * Calculation of drug concentration. * Network: connecting with central station, other Bed observation and software updating. Connection mode: wireless and wired. * Built-in rechargeable battery for uninterrupted monitoring. * Print ECG, SpO2, RESP, BP and temperature data with one-key. Performance: ECG(standard) Lead Mode 3-lead and 5-lead are optional Lead Selection I, II, III, avR, avL, avF, V Wave 5-lead: 2 channels 3-lead: 1channel Gain x2.5mm/mV, x5.0mm/mV, x10mm/mV, x20mm/mV HR Measuring and Alarm Range Range 15 ~ 300 bpm Accuracy ±1% or ±1bpm, which is greater Alarm Accuracy ±2bpm Resolution 1 bpm CMRR Monitor >= 100 dB Surgery >= 100 dB Diagnosis >= 60 dB Bandwidth   Surgery 1 ~ 20 Hz(+0.4dB,-3dB) Monitor   0.5 ~ 40 Hz(+0.4dB,-3dB) Diagnosis 0.05~75Hz(+0.4dB,-3dB); 76Hz~150Hz(+0.4dB,-4.5dB) Calibration Signal 1 mV (Vp-p), ±5%  Accuracy ST Segment Monitoring Measuring and alarm Range -0.6 mV~ + 0.8 mV ARR ARR Detecting Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY,  R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Alarm Available Review Available Scan Speed for ECG Waveform is adjustable: 12.5mm/s accuracy ±10% 25mm/s accuracy±10% 50mm/s accuracy±10% Respiration(standard) Method R-F(RA-LL) Impedance Differential Input Impedance >2.5 M? Measuring Impedance Range 0.3~5.0? Baseline Impedance Range 100?~ 2500? Bandwidth 0.3 ~ 2.5 Hz Resp. Rate Measuring and Alarm Range 0~120rpm Resolution 1 rpm Measureing Accuracy ±2 rpm Alarm accuracy  ±3rpm Apnea Alarm  10 ~ 40 S NIBP(standard) Method Oscillometry Mode Manual, Auto, Continuous Measuring Interval in AUTO Mode 1~90 Min Measuring Period in Continuous Mode 5 Min Measuring and Alarm Range 10~270mmHg Alarm Type SYS, DIA, MEAN Resolution: Pressure  1mmHg Cuff pressure ±3 mmHg Accuracy ±10% or ±8mmHg, which is greater Over-pressure Protection: Adult Mode 315±10 mmHg Pediatric Mode 265±10 mmHg Neonatal Mode 155±10 mmHg SpO2(standard) Measuring Range 0 ~ 100 % Alarm Range 0 ~ 100 % Resolution 1 % Accuracy               70% ~ 100% ±2%               0% ~ 69% unspecified Pulse Rate(PR) Measuring and Alarm Range 0~250bpm Resolution 1bpm Measuring Accuracy ±2bpm or ±2%, which is greater Alarm Accuracy ±2bpm TEMP(standard) Channel dual-channel Measuring and Alarm Range 0 ~ 50°C Resolution 0.1°C Accuracy ±0.1°C Actualization Interval about 1 Sec. Average Time Constant < 10 Sec. Alarm responding Time
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand contec

Directions

Similar products from Pulse Oxymeters

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies